Difference: PowerSupply (1 vs. 10)

Revision 92015-08-18 - MarkusJoos

Line: 1 to 1
 
META TOPICPARENT name="WebHome"
Line: 49 to 49
 
Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=114
  • Telnet connection via LAN bl4s-hv-01.cern.ch port 1527
Added:
>
>

Troubleshooting

Check Interlock mode on front panel - should be in 'closed' mode - LED off.
 

A1833 HV Module

Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=116
  • Comes in P and N variants (Positive and Negative)

Revision 72015-08-11 - TimBrooks

Line: 1 to 1
 
META TOPICPARENT name="WebHome"
Added:
>
>

Requirements

 The detectors require a range of power supplies. Here is a list of requirements:

HighVoltage

Changed:
<
<
>
>
 
Line: 41 to 44
 
  • 0.5mA / 1mA
  • LEMO HV output
Added:
>
>

SY1527 system

SY2537 HV Mainframe

Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=114
  • Telnet connection via LAN

A1833 HV Module

Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=116
  • Comes in P and N variants (Positive and Negative)
HV must be externally enabled by grounding HV EN LEMO input.
 

SY127 system

SY127 Mainframe

Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=200

Revision 62015-06-23 - TimBrooks

Line: 1 to 1
 
META TOPICPARENT name="WebHome"
The detectors require a range of power supplies. Here is a list of requirements:
Line: 21 to 21
 

NIM

VME

Added:
>
>

Lab Supplies

Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=4814
  • 0-32V
  • 0-3A
  • Banana sockets for outputs/sense lines.
 

NIM Modules

CAEN N470

Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=88

Revision 52015-03-21 - TimBrooks

Line: 1 to 1
 
META TOPICPARENT name="WebHome"
The detectors require a range of power supplies. Here is a list of requirements:
Line: 16 to 16
 
  • MRPC - NINO front-end cards require +2.5V and -2.5V (x4 = 2 cards x 2 modules)
  • StrawTracker
Added:
>
>

CrateSupply

Some crates have CANbus control interfaces. Raspberry Pi CANbus interface

NIM

VME

 

NIM Modules

CAEN N470

Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=88

Revision 42015-03-21 - TimBrooks

Line: 1 to 1
 
META TOPICPARENT name="WebHome"
The detectors require a range of power supplies. Here is a list of requirements:
Line: 7 to 7
 
Changed:
<
<
  • MRPC - Around +7kV and -7kV at 3mA for a differential 14kV (2 pairs)
>
>
  • MRPC - Around +7kV and -7kV at 3mA for a differential 14kV (2 pairs) - 2 N570s or a A329N and P
 
Line: 16 to 16
 
  • MRPC - NINO front-end cards require +2.5V and -2.5V (x4 = 2 cards x 2 modules)
  • StrawTracker
Added:
>
>

NIM Modules

CAEN N470

Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=88
  • 8kV / 4kV / 3kV
  • 1mA / 2mA / 3mA
  • SHV output

CAEN N570

Product page
http://www.caen.it/csite/CaenProd.jsp?parent=21&idmod=242
Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=183
  • 15kV / 10kV
  • 0.5mA / 1mA
  • LEMO HV output

SY127 system

SY127 Mainframe

Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=200

SY127 Main controller

Manual
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=137

CAEN A329N & P

Datasheet
https://aismisc.cern.ch/aismisc/ess.file_utils.download_pooldoc_file?pooldoc_id_in=180
  • 15kV
  • 1mA
  • LEMO HV output
 -- TimBrooks - 2015-03-14 \ No newline at end of file

Revision 32015-03-17 - TimBrooks

Line: 1 to 1
 
META TOPICPARENT name="WebHome"
The detectors require a range of power supplies. Here is a list of requirements:

HighVoltage

Changed:
<
<
>
>
 

LowVoltage

Changed:
<
<
  • DelayWireChamber - +6V and -6V for front-end amplifiers
  • MRPC - NINO front-end cards require +2.5V and -2.5V
>
>
  • DelayWireChamber - +6V and -6V for front-end amplifiers (x2-3)
  • MRPC - NINO front-end cards require +2.5V and -2.5V (x4 = 2 cards x 2 modules)
 

-- TimBrooks - 2015-03-14 \ No newline at end of file

Revision 22015-03-15 - TimBrooks

Line: 1 to 1
 
META TOPICPARENT name="WebHome"
The detectors require a range of power supplies. Here is a list of requirements:
Line: 7 to 7
 
Changed:
<
<
  • MRPC - Around +7kV and -7kV for a differential 14kV
>
>
  • MRPC - Around +7kV and -7kV at 3mA for a differential 14kV
 

LowVoltage

Revision 12015-03-14 - TimBrooks

Line: 1 to 1
Added:
>
>
META TOPICPARENT name="WebHome"
The detectors require a range of power supplies. Here is a list of requirements:

HighVoltage

LowVoltage

-- TimBrooks - 2015-03-14

 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright & 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.