Difference: FarmE10 (1 vs. 4)

Revision 42008-04-08 - LoicBrarda

Line: 1 to 1
 
META TOPICPARENT name="PortsUX01"

Sub-Farm D1E10 (vlan 910)

Sub-nets:

Line: 15 to 15
 

Switches

Type Name Serial MAC
Changed:
<
<
Control sw-d1e10-c1   00:15:60:18:b6:00
Data sw-d1e10-d1   00:16:B9:0c:3e:80
>
>
Control sw-d1e10-c1 TW546SD0R8 00:15:60:18:b6:00
Data sw-d1e10-d1 SG652TH00Y 00:16:B9:0c:3e:80
 

Computers

Revision 32008-04-08 - LoicBrarda

Line: 1 to 1
 
META TOPICPARENT name="PortsUX01"

Sub-Farm D1E10 (vlan 910)

Sub-nets:

Line: 11 to 11
 

Ports used:

Port host(s) Comment
Gi 1/4 sw-d1e10-c1 farm uplink
\ No newline at end of file
Added:
>
>

Switches

Type Name Serial MAC
Control sw-d1e10-c1   00:15:60:18:b6:00
Data sw-d1e10-d1   00:16:B9:0c:3e:80

Computers

Name Serial base MAC Data patched to SW-DAQ-01 port
hlte10 35Q222J 00:14:22:B0:C7:D7    
hlte1001   00:15:c5:e5:3a:a2 D2B1C04 Gi 0/54
hlte1002 SVXXD2J 00:13:72:fa:ff:7a
hlte1003 7VXXD2J 00:13:72:fa:ff:84 D2B1C05 Gi 0/55
hlte1004 9VXXD2J 00:13:72:fb:0d:6c

Steps

Install & Cable Control & Data switches X
Enter info in hlt_nodes.csv X
Connect the uplink in D2 to the main control switch X
Configure the swiches addresses in DNS & DHCP X
Configure SW-UX-01 X
Power on the switches X
Configure the control switch X
Update the Data switch firmware X
Configure the Data switch X
Install the Server X
Connect data cables in D2 & configure SW-DAQ-01 X
Connect the storage uplink X
Install and boot the nodes X
Test the connectivity X
Ask for PVSS license X
Install the pvss_licence on the node and in /var/www/html/pvss/licences on sw-sx-01. X
 \ No newline at end of file

Revision 22007-10-08 - LoicBrarda

Line: 1 to 1
 
META TOPICPARENT name="PortsUX01"

Sub-Farm D1E10 (vlan 910)

Sub-nets:

Line: 6 to 6
 
  • 10.131.154.254 / 24

Ports:

Changed:
<
<
  • Gi 1/32 - Gi 1/33

Port-channels (a.k.a. aggregated links):

ID member ports
Po 104 Gi 1/32-33
>
>
  • Gi 1/4
 

Ports used:

Port host(s) Comment
Deleted:
<
<
Po 104 sw-d1e10-c1 farm uplink, only Gi 1/32 used
 \ No newline at end of file
Added:
>
>
Gi 1/4 sw-d1e10-c1 farm uplink
 \ No newline at end of file

Revision 12007-08-09 - LoicBrarda

Line: 1 to 1
Added:
>
>
META TOPICPARENT name="PortsUX01"

Sub-Farm D1E10 (vlan 910)

Sub-nets:

  • 10.130.154.254 / 24
  • 10.131.154.254 / 24

Ports:

  • Gi 1/32 - Gi 1/33

Port-channels (a.k.a. aggregated links):

ID member ports
Po 104 Gi 1/32-33

Ports used:

Port host(s) Comment
Po 104 sw-d1e10-c1 farm uplink, only Gi 1/32 used
 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright & 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback