Difference: L0MuonHowToTimeAlignedL0DU (1 vs. 2)

Revision 22008-02-20 - RenaudLeGac

Line: 1 to 1
 
META TOPICPARENT name="L0Muon"
This document explain how to time aligned the L0DU with respect to the L0 Muon processors

Added:
>
>
  • Activate L0DU in ODIN
    In ECS tab, in External Triggers section, tick L0DU Enable and Apply display.
  The time alignment is performed in 3 steps:

  1. L0DU BCid with respect to ODIN BCid
    • L0DU Basic setup tab.
Changed:
<
<
    • Play with the offset on the top right part of the panel.
    • Check on the ODIN panel that the BCid of ODIN and BCid of L0DU are equal.

>
>
    • Latencies sub-tab
    • Play with the offset on the subpanel L0DU Local BCID (top right part of the panel).
    • Check on the ODIN panel that the Bunch IDs of ODIN (first one) and those of L0DU are equal (second one).

 
  1. L0 Muon candidates with respect to others candidates
    • L0DU Basic setup tab.
Changed:
<
<
    • On Link B aligned muon candidates with respect to each others
    • Select the reference for the Muon Candidates
    • On Link A aligned the muon reference with respect to the others candidates

>
>
    • Latencies sub-tab
    • In Link B sub-panel aligned muon candidates with respect to each others using latencies slider and Apply.
    • In BCID Monitoring, select the reference for the Muon Candidates, i.e MuC2 and Apply.
    • In Link A sub-panel aligned the muon reference with respect to the others candidates

 
  1. L0DU Latency
    • Set ODIN in external trigger
    • L0DU Basic setup tab
Changed:
<
<
    • Click on single pulse on the right side of the panel
    • Then click on Apply
>
>
    • Latencies sub-tab.
    • In L0DU/ODIN sub-panel, click on single pulse and Apply.

  -- RenaudLeGac - 20 Feb 2008

Revision 12008-02-20 - RenaudLeGac

Line: 1 to 1
Added:
>
>
META TOPICPARENT name="L0Muon"
This document explain how to time aligned the L0DU with respect to the L0 Muon processors

The time alignment is performed in 3 steps:

  1. L0DU BCid with respect to ODIN BCid
    • L0DU Basic setup tab.
    • Play with the offset on the top right part of the panel.
    • Check on the ODIN panel that the BCid of ODIN and BCid of L0DU are equal.

  2. L0 Muon candidates with respect to others candidates
    • L0DU Basic setup tab.
    • On Link B aligned muon candidates with respect to each others
    • Select the reference for the Muon Candidates
    • On Link A aligned the muon reference with respect to the others candidates

  3. L0DU Latency
    • Set ODIN in external trigger
    • L0DU Basic setup tab
    • Click on single pulse on the right side of the panel
    • Then click on Apply

-- RenaudLeGac - 20 Feb 2008

META TOPICMOVED by="RenaudLeGac" date="1203499514" from="LHCb.L0MuonHoxToTimeAlignedL0DU" to="LHCb.L0MuonHowToTimeAlignedL0DU"
 