Difference: Rich1UpgradeMechanicsServices (4 vs. 5)

Revision 52016-01-28 - MichaelMcCann

Line: 1 to 1
 
META TOPICPARENT name="Rich1UpgradeMechanics"

RICH 1 Upgrade Services

Line: 78 to 82
  patch.png
Changed:
<
<
For the HV: Assume split poweing of last and second to last dynode + 2 spare channels = 100 so 10x10 SHV array (internal). The inside is the setting the limits, the 56 conductor cables. SHV connector ~ 15mm + 10 mm finger room -> 260mmx260mm patch panel. Would need t be quite thick though.
>
>
For the HV: Assume split poweing of last and second to last dynode + 2 spare channels = 100 so 10x10 SHV array (internal). The inside is the setting the limits, the 56 conductor cables. SHV connector ~ 15mm + 10 mm finger room -> 260mmx260mm patch panel. Would need t be quite thick though.
 

Internal cabling

Line: 95 to 98
 
HV 12,16,20 HV coax 3 mm diameter 20 mm Something like 20 pin HV socket 20 pin HV plug SHV 1,2 or 3 HV per PDM + 1 ground
DCS/DSS 12 Some wire         A thermoswitch per PDM?
Added:
>
>
A cross-section of the potential cable routing assuming above, in a 56x100mm space, with a 15 mm central support structure.

cross-section_with_central_support.png

 
META FILEATTACHMENT attachment="patch.png" attr="" comment="" date="1424804273" name="patch.png" path="patch.png" size="18474" user="mmccann" version="1"
Added:
>
>
META FILEATTACHMENT attachment="cross-section_with_central_support.png" attr="" comment="" date="1453977653" name="cross-section_with_central_support.png" path="cross-section_with_central_support.png" size="65450" user="mmccann" version="1"
 