Recording data

Changed:
<
<
The voltages of the last and last by one dynodes are recording using a LabView vi. Start the TB2017/Read Measurement Data shortcut. Run the vi and save the file in TB2017/data/dynodes folder.

The current of the photocatode and the last dynode are read by multimeters. In order to start the recording of data, start the TB2017/SX-DMM v2.6 shortcut on pclhcb182. Press OK. Do not reduce to icon the window otherwise the software get stuck.

When you want to stop the acquisition save the file in TB2017/data/dynodes folder.

>
>
The voltages of the last and last by one dynodes are recording using a LabView vi. Start the TB2017/Read Measurement Data shortcut. Run the vi and save the file in TB2017/data/dynodes folder. The data will be recorded every second until the vi is stopped.
 
Added:
>
>
The current of the photocatode and the last dynode are read by multimeters. In order to start the recording of data, start the TB2017/SX-DMM v2.6 shortcut on pclhcb182. Press OK. Do not reduce to icon the window otherwise the software get stuck. In order to save data, press the Stop button and then the Save button. Save the file in TB2017/data/dynodes folder.
  -- LhcbTestbeamSupportService - 2017-05-29
 