Stations 1,2,4,5 dV=2.5V 100k events X 18 ok // ok // //  
Stations 1,2,4,5 dV=3.0V 100k events X 19 ok // ok // //  
Stations 1,2,4,5 dV=3.5V 100k events X 16 ok // ok // //  
Changed:
<
<
Stations 1,2,4,5 dV=4.0V 100k events X 20 ok // desynchronisation from ~ev.38k (X3 Y3) // //  
>
>
Stations 1,2,4,5 dV=4.0V 100k events X 20
(no use)
ok // desynchronisation from ~ev.38k (X3 Y3) // //  
 
Stations 1,2,4,5 dV=4.0V 100k events X 25 Noise cluster due to DCR // ok // // Rerun 20 due to desynchronisation. Use (pedestal, 24) and (LED,20)
Stations 1,2,4,5 dV=4.5V 83k events X 21 ok // ok // // stopped at 83k because of access
Stations 1,2,4,5 dV=5.0V 100k events X 22 Noise cluster due to DCR // ok // //  
 