Difference: Vacuum1 (4 vs. 5)

Revision 52008-08-05 - EddyJans

Line: 1 to 1
 
META TOPICPARENT name="VELOOperatingManuals"

Operating the VELO Vacuum System under beam conditions

Changed:
<
<
Make sure the PVSS-project "VEDCS_VacMot" is running under "velo_user" on "vedcs02w". If not, start it and also start via "Vision" the panel G:\velo\pvss\VELO_VacuumMotion\panels\VeloVacuum_UI_Main.pnl
  • Click on "Show Details" (left top) to get access to the reading of the vacuum meters.
  • The most important ones are the 4 red enrectangulared ones: PE411 and PE412, which give the pressure in the beam volume in mbar. The pressure in the detector volume of the VELO is given by PE421 and PE422.
>
>
Make sure the PVSS-project "VEDCS_VacMot" is running under "velo_user" on "vedcs02w". If not, start it. If "gedi" is not running, start it. Start via "Vision" the panel G:\velo\pvss\VELO_VacuumMotion\panels\VeloVacuum_UI_Main.pnl
  • Click on "Show Details/Hide Details" (left top) to get more/less information of vacuum meters.
  • The most important ones are the 4 red encircled ones: PE411 and PE412 give the pressure in the beam volume in mbar. The pressure in the detector volume of the VELO is given by PE421 and PE422.
 
  • The status of the sector valves VVFSF.33.1L8.X and VVGST.221.1R8.X will in the near future also be displayed at the left/right.
Added:
>
>
  • The overall state of the vacuum system is representd by the field "Current state" on the bottom of the panel. The state "Ready for Beam" is what you need, from the vacuum point of view, to permit injection of beams into LHC.
 
pvvs.vacuumscreen2.bmp.jpg
Changed:
<
<
Trend plots of these pressures can easily be obtained in the following way:
>
>
Trend plots of these pressures can be obtained in the following way:
 
  • Left-click button 'Open Graph Select' in the top left corner
  • Select "VEDCS_VacMot" << "Vac_VesselSide" << "Pennings_vessel"
  • right-click it
Line: 20 to 21
  The actual readings of gauges, valves and pumps can also be seen at the page named "Vacuum scheme" on the PLC-screen in rack C3B05 on platform C3. To display it, touch the screen once to get rid of the screensaver and then press the encircled button as shown in the figure below.
Changed:
<
<

screenshot.4b.jpg
>
>

screenshot.mainpanel.2.jpg
  -- EddyJans - 31 Jul 2008
Line: 25 to 25
  -- EddyJans - 31 Jul 2008
Deleted:
<
<
 
META FILEATTACHMENT attachment="pvvs.vacuumscreen.bmp.jpg" attr="" comment="" date="1217509518" name="pvvs.vacuumscreen.bmp.jpg" path="C:\VELO\SCREEN\pvvs.vacuumscreen.bmp.jpg" size="109702" stream="C:\VELO\SCREEN\pvvs.vacuumscreen.bmp.jpg" user="Main.EddyJans" version="1"
META FILEATTACHMENT attachment="pvvs.vacuumscreen2.bmp.jpg" attr="" comment="" date="1217518523" name="pvvs.vacuumscreen2.bmp.jpg" path="C:\VELO\SCREEN\pvvs.vacuumscreen2.bmp.jpg" size="113427" stream="C:\VELO\SCREEN\pvvs.vacuumscreen2.bmp.jpg" user="Main.EddyJans" version="1"
Changed:
<
<
META FILEATTACHMENT attachment="screenshot.4b.jpg" attr="" comment="" date="1217775437" name="screenshot.4b.jpg" path="C:\Documents and Settings\Administrator\My Documents\APDP\screenshot.4b.jpg" size="74449" stream="C:\Documents and Settings\Administrator\My Documents\APDP\screenshot.4b.jpg" user="Main.EddyJans" version="1"
>
>
META FILEATTACHMENT attachment="screenshot.4b.jpg" attr="" comment="" date="1217941802" name="screenshot.4b.jpg" path="screenshot.mainpanel.2.jpg" size="66721" stream="screenshot.mainpanel.2.jpg" user="Main.EddyJans" version="2"
META FILEATTACHMENT attachment="screenshot.mainpanel.2.jpg" attr="" comment="" date="1217941946" name="screenshot.mainpanel.2.jpg" path="screenshot.mainpanel.2.jpg" size="66721" stream="screenshot.mainpanel.2.jpg" user="Main.EddyJans" version="1"
 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright & 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback