Difference: WindowsPvssAutoStartup (1 vs. 3)

Revision 32008-05-05 - GaryMoine

Line: 1 to 1
 
META TOPICPARENT name="UserGuide"

Automatic startup of PVSS projects at boot time as a Windows Service

Line: 13 to 13
  All projects should have manual startup for all UIs.
Changed:
<
<

Starting the Project as a Windows service

>
>

Starting-Stopping a Project run as a Windows service

 
Changed:
<
<
When the configuration of the service is fully tested, the Project service is defined as an automatic service started at boot time, and only PVSS UI needs to be manually attached to the project. Anyway it coult be possible to stop and start the service with:
>
>
When the configuration of the service is fully tested, the Project service is defined as an automatic service started at boot time, and only PVSS UI needs to be manually attached to the project.
Nevertheless it is possible to stop and restart the service when the computer operate normally:
To allow a clean shutdown of the PVSS project started as a service, a Stop service has been implemented called "ProjectServiceName"-Stop (ie: MUHVA02-Stop).
If this Stop service is not used, but the main Service is stopped, pmon process will be killed without waiting for others PVSS managers processes to stop. Then on next Startup a DataBase Repair will occur ...
By using this Stop service, a PVSS00pmon.exe -stopWait is sent to the running project which will cause a proper shutdown as performed with the Project Administration UI ( or the Console one ).

So the correct procedure to STOP-RESTART your PVSS project started as a service is :

  1. Start the STOP service: It should take few second to complete depending of numbers of managers to stop.
  2. Start the PROJECT service: This should be done only when the Project has been successfully stopped.

Available tools for managing services are:

 
  • Windows services standard UI ( launch services.msc )
  • Service + UI
Changed:
<
<
  • From the command line: > net start [stop] "Service Name"
>
>
  • And from the command line:
    >net start "Service Name"-Stop (ie: net start MUHVA02-Stop )
    >net start "Service Name" (ie: net start MUHVA02 ) ## Please wait for the full stop of the project before starting it again!

The Stop service is always in stopped status with a Manual startup type. And when started will always return to it stopped status after the project stop ...

 

Attaching a PVSS UI to a project started as a service:

Revision 22008-04-29 - GaryMoine

Line: 1 to 1
 
META TOPICPARENT name="UserGuide"

Automatic startup of PVSS projects at boot time as a Windows Service

Line: 9 to 9
 
  • Name of the project[s]
  • Name of the Windows service ( usually the PVSS project name seems to be the best choice...) and a description for the service ( ie: Muon High Voltage side A)
  • If project config file is not in L:\localdisk\pvss\< PROJECT NAME >\config, provide its location ( but it should not be different if you follow the LHCb ECS Integration Guideline https://edms.cern.ch/file/732486/3/LHCb_ECS_Guidelines.pdf smile )
Added:
>
>
  • Tell us if your project need to start an OPC server, because in this case specific rights need to be granted to the account ( "group" operator ) from which service is started
  All projects should have manual startup for all UIs.
Line: 20 to 21
 
  • Service + UI
  • From the command line: > net start [stop] "Service Name"
Added:
>
>

Attaching a PVSS UI to a project started as a service:

 
Changed:
<
<
-- GaryMoine - 28 Apr 2008
>
>
After logging to a control PC where a PVSS project is started as a service, you need to manually attach a PVSS UI to the running project. You can start PVSS Gedi by running:

C:\ETM\PVSS2\3.6\bin\PVSS00ui.exe -proj "PROJECT NAME"
or
C:\ETM\PVSS2\3.6\bin\PVSS00ui.exe -config "Path to config file"

Or you can start a specific panel with "-p" option:

C:\ETM\PVSS2\3.6\bin\PVSS00ui.exe -proj "PROJECT NAME" -p fwInstallation\fwInstallation.pnl (## You must provide the path to the panel starting from PVSS root ##)
to start the FrameWork installation tool

For all others options , try:

C:\ETM\PVSS2\3.6\bin\PVSS00ui.exe -help

-- GaryMoine - 29 Apr 2008

Revision 12008-04-28 - GaryMoine

Line: 1 to 1
Added:
>
>
META TOPICPARENT name="UserGuide"

Automatic startup of PVSS projects at boot time as a Windows Service

Configuration of Service + on control PC

To have PVSS projects started at boot time under Windows, please send a mail to Online Helpdesk: lbonsupp@cernNOSPAMPLEASE.ch with the following information :

  • Name of the computer where the project[s] will run on
  • Name of the project[s]
  • Name of the Windows service ( usually the PVSS project name seems to be the best choice...) and a description for the service ( ie: Muon High Voltage side A)
  • If project config file is not in L:\localdisk\pvss\< PROJECT NAME >\config, provide its location ( but it should not be different if you follow the LHCb ECS Integration Guideline https://edms.cern.ch/file/732486/3/LHCb_ECS_Guidelines.pdf smile )

All projects should have manual startup for all UIs.

Starting the Project as a Windows service

When the configuration of the service is fully tested, the Project service is defined as an automatic service started at boot time, and only PVSS UI needs to be manually attached to the project. Anyway it coult be possible to stop and start the service with:

  • Windows services standard UI ( launch services.msc )
  • Service + UI
  • From the command line: > net start [stop] "Service Name"

-- GaryMoine - 28 Apr 2008

 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright & 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.