Difference: MdtShifter (6 vs. 7)

Revision 72008-02-29 - AlbertoBelloni

Line: 1 to 1
 
META TOPICPARENT name="AlbertoBelloni"

MDT Shift Manual

Line: 92 to 92
  Check with Joerg (Barrel) and Jainbei (Endcap) about the gas status of the MDT chambers.
Changed:
<
<
If the HV is off and the chambers have adequate gas, the HV can be turned on using the DCS GUI. The trip current should be raised to 25$\muA$ while turning on the HV. Once the full voltage is reached, the trip current should be lowered to $5\mu$A, and checks should be made to ensure that the current is close to zero.
Latex rendering error!! dvi file was not created.
>
>
If the HV is off and the chambers have adequate gas, the HV can be turned on using the DCS GUI. The trip current should be raised to $25\mu$A while turning on the HV. Once the full voltage is reached, the trip current should be lowered to $5\mu$A, and checks should be made to ensure that the current is close to zero.
  In case the DCS GUI does not work, it is possible to access the mainframe directly from a terminal with the command:
 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright & 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.