The trigger monitor is controlled by the alitoftrg PC. The VME server
is named (/home/tof/SOFT/TRG/CTTM/test/running_server_v2) .
This process has to be killed before reprogramming the FPGAs.It can be
restarted only when reprogramming is finished with the command.
ResetCrate alitoftrg 0 :
The steps performed are:
:

when STDBY_CONFIGURED
:

  • set the clock (internal/Aliclk);
  • update the threshold for the PYGGY TOP and BOTTOM;
  • set the thresholds for the MBT trigger,

when READY
:

  • Check for CRC;
  • VME reading of the 2x1728 scalers implemented in the FPGAs, containing the rates of each
    input channel (before and after the blocking process) and writes them in a file;
  • VME reading of the 8 scalers containing the trigger rates;

The values are published on a dim server and visualized by PVSS
in the CTTM window of the TOF base panel.

-- EugenioScapparone - 16 Sep 2008

Edit | Attach | Watch | Print version | History: r2 < r1 | Backlinks | Raw View | WYSIWYG | More topic actions