SDC (Scalable Detector Control)

Introduction

SDC Will be soon Updated to v.2 SDC (Scalable Detector Control ) was introduced on November 2010 for the remote control of the SRS (Scalable Readout System). It was developed in order to replace the existing way of initializing the readout electronics of Micromegas Chambers which was through the Xilinx Chip Scop Pro Analyzer which was connected through DLC9G USB interface. The need of that came from the decision to install test chambers in ATLAS cavern on which only the remote, through ethernet, solution seemed to let us continue. The interface communicates with UDP protocol packets with the FEC cards. The basic idea is that the communication is established to a specific IP address or a range of IP addresses and to different ports. Each port is identical for a kind of peripheral.

Packet Design

Each value on a packet has 32bits and is starting with the request ID which is the number that the FEC card will respond in order to provide information about the success or not of the command.

SDC and QT

The final decision to develop such a tool to Qt came from two main reasons:
  • Cross Platform application
  • Need of a UI
Both of them are satisfied in Qt. The final application is really working stably on MAC OS X, Ubuntu, SLC 5 and should also work (although not tested) on Windows giving a very good flexibility.

Initialization Sequence

In order to succeed a full initialization the steps that needs to be followed are:
  • Check first the connection label if it's true. If false press connect. If true connection is not succeed means that port 6007 is occupied by another program on your PC.
  • Select ADC card from choose peripheral and press Configure. Press Apply and then Send button on the right of the panel (not send all). The utility start automatically on ADC pre-selected.
  • Select APV Hybrid and then follow the same: Apply->Send. (sometimes after this step is good to give a Hybrid Reset command)
  • Select APV Application and then the same: Apply->Send.
  • Select PLL and the same: Apply-> Send.

You can close the windows after pressed Apply and before pressing Send. You should be now fully initialized. Keep in mind that every peripheral widget is opening with the default values.

Main Interface

Opening the application someone gets the following image. The UI is divided in two large areas: the sending area and the Reply area. The first one is subdivided into other which will be explained in the following sections. At the starting point the app is trying to open the connection from the local PC which means that is checking if the port 6007 (which is the listener port also). This step is very important. If this port is occupied by another application the communication with the FEC card is impossible because the source port of the UDP packets should be this one. In addition an error is occurred. If you want manually to open the connection press the connect button on the top left side and the label should be turn to TRUE indicating a successful occupy of that port. False is the alternative response. Is IMPORTANT to keep in mind that since the communication is done through UDP protocol means that no actual connection is establishing and only a virtual one. Also the IP of the FEC should be configured at this point because the default one is preconfigured for the need of FEC card installed on ATLAS Cavern.

sdc.png

FEC Properties

At this area the FEC properties are configured. First the IP address and after that the "virtual" communication. After that there is the area of peripherals which is easily expandable for future purposes and the configure button that will be described later. There are also the "Recipe File" field and the reset commands for the FEC

fec.png

FEC Resets

This field is a very expert field and that's why you will be asked to agree if you really know what command you are about to send. If you agree in the popup window the resets area will be enabled and you will be able to send a command. After that the area is disabled again to avoid multiple sending. The available commands are:

  • Warm Initialization which is a soft reset on FEC
  • Force Reboot which is a hard reboot command in case of troubles.

resets.png

Recipe Files

On this field someone can load a Recipe file and send the full initialization to FEC. The file must have been created with this tool otherwise for security reasons the tool won't let you load it. You will get a message in case of successful load. The file must have a structure with:

  • First the ADC Port and identifier 1 which are 16bit each and then the full packet for this peripheral.
  • Second the APV Hybrid Port and identifier 2 which are 16bit each and then the full packet for this peripheral.
  • Thirdly the APV Application Port and identifier 3 which are 16bit each and then the full packet for this peripheral.
  • Finally the PLL Port and identifier 4 which are 16bit each and then the full packet for this peripheral.

Like that there is easily the ability to create new coming chips without loosing the existing files. To create a Recipe file someone has to follow the initialization sequence described above but instead of sending should press the save to file button on each configuration panel. Once you successfully load a Recipe file you can easily load each peripheral values by clicking the Load from file on each configuration window. You can easily also replace the data for the specific peripheral also by saving each configuration to the same file.

conffiles.png

Peripheral Configuration

Pressing the configure button a new widget will open depending your selection on the left Peripheral selection Radio Button. If you have already loaded a Recipe file the data on the file are already available if you press load from file button. In different case a popup window will warn you that no file is loaded and if you want you can load one already created before.

configureButton.png

ADCCARD registers (port 6519)

Here are the addresses and the default values for the ADC Card:

Name Address(hex) Value(hex)
BCLK_ENABLE 06 xFF
HYBRID_RST_N 00 xFF
PWRDOWN_CH0 01 x00
PWRDOWN_CH1 02 x00
EQ_LEVEL_0 03 x00
EQ_LEVEL_1 04 x00
TRGOUT_ENABLE 05 x00

ADC.png

APV Hybrid registers (port 6263)

These are the addresses and default values for APV Hybrids:

Name Address Value(hex)
CSEL 0011101x b11110111
MODE 0000001x b00011001
LATENCY 0000010x 128
MUXGAIN 0000011x b00000100
IPRE 0010000x 98
IPCASC 0010001x 52
IPSF 0010010x 34
ISHA 0010011x 34
ISSF 0010100x 34
IPSP 0010101x 55
IMUXIN 0010110x 16
ICAL 0011000x 100
VPSP 0011011x 40
VFS 0011010x 60
VFP 0011001x 30
CDRV 0011100x b11101111

  • Sometimes is useful to send a reset command after sending initialization of this.

APVH.png

The MODE address is one of the very useful and the values that are used are described in the following table.

APV MODE Values:

Bit Number Function Value(0) Value(1)
0 Analogue Bias OFF ON
7 Not used - -
6 Not used - -
5 Preamp Polarity Non-Inverting Inverting
4 Read-out Frequency 20MHz 40MHz
3 Read-out Mode Deconvolution Peak
2 Calibration Inhibit OFF ON
1 Trigger Mode 3-sample 1-sample

APV Applications registers (port 6039)

These are the addresses and default values for APV Applications :

Name Address(hex) Value(hex)
EVBLD_EVENTINFODATA 0C hAABB0BB8
BCLK_MODE 00 b00000111
BCLK_TRGBURST 01 4
BCLK_FREQ 02 4000
BCLK_TRGDELAY 03 256
BCLK_TPDELAY 04 128
BCLK_ROSYNC 05 300
EVBLD_CHMASK 08 hffff
EVBLD_DATALENGTH 09 3000
EVBLD_MODE 0A 0
EVBLD_EVENTINFOTYPE 0B 0

APVA.png


BCLK_TRGBURST: controls how many time slots the APV chip is reading from its memory. The formula is (n + 1) x 3. Setting this to 4 means a number of 15 time slots. The maximum is 30 time slots (n = 9).
BCLK_TRGDELAY: The FPGA delays the trigger for this number of clock-cycles (25ns) until propagating it to the chip. The global latency of the trigger is the difference between APV_LATENCY and BCLK_TRGDELAY.
BCLK_FREQ: When trigger source is set to external, this parameter controls the deadtime introduced by the FPGA. After accepting a trigger, the FPGA will ignore all triggers incoming for Bclk_freq x 64 x 25ns time. 40000 means 1ms. This time should not be lower than the total acquisition time of one event which is about 222 us (with default parameters). When the trigger source is set to internal, this parameter controls the repetition rate of the internal generated trigger.

The BCLK_MODE address is one of the very useful and the values that are used are described in the following table.

BCLK_MODE Values:

Bit Number Function Value(0) Value(1)
0 APV Reset disabled enabled
7 Not used - -
6 Not used - -
5 Not used - -
4 Not used - -
3 TRGIN polarity NIM Inverse NIM
2 TRIGGER mode Continuous loop Controlled by TRGIN
1 APV Test Pulse disabled enabled

PLL registers (port 6263)

These are the addresses and default values for PLL :

Name Address(hex) Value
TRG_DELAY 03 0
CSR1_FINEDELAY 01 b00010000

PLL.png

Configurations

In these field someone can configure first the command type of sending. There are options to send packets for Master/Slave APV or Both of them as to define which of the channels (HDMI) you want to initialize. Keep in mind that this has to do with the kind of the peripheral you are using. The app by default changes this option when you do through peripherals. All channels are preselected bey default.
Note down that there is no problem to select a channel that has no connection.

configurations.png

Write/Read Mode

This has to do with the type of initialization. Write Pairs is preselected. Pairs means that the initialization is done by defining the address and value you are writing. Burst means you specify first the address and then all values the you want to write which correspond to coming addresses. The same philosophy is applied on Read commands.

commands.png

Trigger

This is a shortcut to BCLK_MODE APV Application described above and you can easily change the trigger control.

trigger.png

Acquisition

From here you can start or stop the Data Acquisition. Keep in mind that the FEC boots with ACQ OFF.

acq.png

Hybrid Resets

This is a reset commend, useful after APV Hybrid configuration/initialization.

hybrid.png

Sending Packets

In this area someone can send commands from the Peripheral configuration recently made. There is also a counter with a unique Request ID to which the FEC will respond with the success of the command.

send.png

Reply Screen & Formats

In this are you are getting important messages. If there is nothing here after you send a packet means that there is no communication with the FEC card. Normally the FEC card will respond to every request you make including an echoing of the Request ID and then a set of Errors which will be equal to Zero in case of success and different in case of error occurred. This form is also used if you want to read already configured values from a peripheral.

reply.png

OS requirements

The requirements to run the tool is the Qt Libraries 4.7 and above which is easily downloadable from Qt Download Center

Version and changes

v1.4.2
  • Fixed Bug on .txt files on SL5, possible to load every type now.
  • By default loading configuration file if present.
  • Fixed bug on Send all command on configuration file.

v1.4.1

  • Added the saving logs functionality
  • Added more security on sending commands
  • Added appending replies to Reply form

v1.4

  • Added Recipe files functionality
  • Fixed ui minor bugs
  • Added Help link on the top that redirects through the web browser to this page.
  • Added Reset functions for the FEC itself.

v1.3

  • First Major release

Developers and Credits

  • George Iakovidis
  • Konstantinos Karakostas
NTUA Group in collaboration with Brookhaven Laboratory

Download

Source Code

  • Ask the developer

Example Configuration File

Linux

Ubuntu and SLC5 verified

MAC OS X

10.6.5 and above verified (although should work in every release of Snow Leopard 10.6.x or Leopard 10.5.x)

Windows

Future Plans

  • Include Broadcasting packets
  • IP Ranges initialization for larger applications.
  • Save logs to file if needed
  • more...


Major updates:
-- GeorgeIakovidis - 08-Apr-2011

Responsible: GeorgeIakovidis
Subject: detector
Last reviewed by: Never reviewed

Topic attachments
I Attachment History Action SizeSorted ascending Date Who Comment
Texttxt sdc_conf_h6_CR2_R14_R18.txt r1 manage 0.4 K 2011-11-23 - 11:28 GeorgeIakovidis  
Compressed Zip archivezip SRSDCS_1.4.1_SCL5.zip r1 manage 119.7 K 2011-04-14 - 19:09 KonstantinosKarakostas  
Unknown file format1_scl5 SRSDCS_1.4.1_SCL5 r2 r1 manage 120.5 K 2011-05-02 - 16:31 GeorgeIakovidis  
Compressed Zip archivezip SRSDCS_1.4.2_SL5.zip r1 manage 120.5 K 2011-05-02 - 16:44 GeorgeIakovidis  
Compressed Zip archivezip SRSDCS_1.4.2_MAC.zip r1 manage 159.3 K 2011-05-02 - 16:47 GeorgeIakovidis  
Edit | Attach | Watch | Print version | History: r24 < r23 < r22 < r21 < r20 | Backlinks | Raw View | WYSIWYG | More topic actions
Topic revision: r24 - 2012-06-20 - PatrickJussel
 
    • Cern Search Icon Cern Search
    • TWiki Search Icon TWiki Search
    • Google Search Icon Google Search

    Atlas All webs login

This site is powered by the TWiki collaboration platform Powered by PerlCopyright & 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback