This page presents public CALICE results. There are two types of publications.
Papers are publications published in (or submitted to) peer-reviewed journals. Those publications with a tag CALICE-PUB-YYYY-NNN went through a review process by the CALICE Collaboration. Papers without this tag are publications, mainly technical papers, by the corresponding projects that didn't went through a formal approval process by CALICE.
AnalysisNotes have been approved for public presentation as "CALICE Preliminary". They represent the current best knowledge of CALICE on a given topic.
"Associated CALICE Analysis Notes" that can be found in the menus below the reviewed papers contain preliminary results obtained in analyses towards a given paper that have been superseded by the paper. Results in there (i.e. in the "Associated CALICE Analysis Notes") must only be used and cited in coordination with the Speakers Bureau Chair and the corresponding author or the corresponding project leader. A complete list of all analysis notes can be found here for reference.
To get to the results of the corresponding project you can scroll down or use one of the links below.
General CALICE ResultsSiW ECAL ResultsScW ECAL ResultsMAPS ECAL ResultsAHCAL ResultsW-AHCAL/DHCAL ResultsTCMT ResultsSDHCAL ResultsDHCAL ResultsT3B Results
Paper04.tar.gz: gzipped including source and figures of CALICE-PUB-2010-001
Associated CALICE Analysis Notes :
CALICE-PUB-2011-001: Effects of high-energy particle showers on the embedded front-end electronics of an electromagnetic calorimeter for a future lepton collider, C. Adloff et al., NIM A 654 (2011), 97; e-print: arXiv:1102.3454
Paper-008.tgz: gzipped tar file including source and figures of CALICE-PUB-2011-001
Beam test performance of the highly granular SiW-ECAL technological prototype for the ILC, K. Kawagoe et al., accepted by NIMA; e-print: arXiv:1902.00110
SiW ECAL analysis notes
CALICE-CAN-2010-004 (was CAN-017): Study of position and angular resolution for electron showers measured with the electromagnetic SiW prototype
CAN-017.tgz: gzipped tar file including source and figures for CALICE-CAN-2010-004
CALICE-CAN-2010-006 (was CAN-023a): Tracking with the CALICE Si-W electromagnetic calorimeter prototype using the Hough transform
CAN-023a.tar.gz: gzipped tar file including source and figures for CALICE-CAN-2010-006
CALICE-CAN-2013-006 (was CAN-046): Study of the response of the CALICE Si-W ECAL Physics Prototype to positrons using data taken at the Fermilab test beam facility
CAN-046.tgz: tar gzip file including source and figures for CALICE-CAN-2013-006
CALICE-CAN-2017-001 (was CAN-057): Separation of two overlapped electromagnetic or electromagnetic-hadronic showers in CALICE highly granular physics calorimeter prototypes using Pandora, Garlic and Arbor Particle Flow Algorithms
CAN-057.zip: zip file including source and figures for CALICE-CAN-2017-001
Monolithic Active Pixel Sensors (MAPS) in a quadruple well technology for nearly 100% fill factor and full CMOS pixels, J. A. Ballin et al., Sensors 2008, 8(9), 5336-5351; e-print: arXiv:0807.2920
Design and performance of a CMOS study sensor for a binary readout electromagnetic calorimeter, J. A. Ballin et al., [[http://dx.doi.org/10.1088/1748-0221/6/05/P05* tar file including source and figures (009][JINST 6 (2011) P05009]]; e-print: arXiv:1103:4265
First radiation hardness results of the TeraPixel Active Calorimeter (TPAC) sensor, T. Price et al., JINST 8 (2013) P01007
MAPS ECAL analysis notes
AHCAL results
AHCAL papers
A high granularity scintillator hadronic-calorimeter with SiPM readout for a linear collider detector. V. Andreev et al. Nucl.Instrum.Meth.A540:368-380,2005.
A high-granularity plastic scintillator tile hadronic calorimeter with APD readout for a linear collider detector. V. Andreev et al. Nucl.Instrum.Meth.A564:144-154,2006.
CALICE-CAN-2008-003 (was CAN-009): The reconstruction of the energy lost by a 120 GeV muon in the highly granular hadroni calorimeter for the International Linear Collider
CAN-009.tgz: gzipped tar file including source and figures for CALICE-CAN-2008-003
CALICE-CAN-2009-003 (was CAN-018): Calibration of the Scintillator Hadron Calorimeter of ILD
CAN-018.tgz: gzipped tar file including source and figures for CALICE-CAN-2009-003
partially included in ILD LoI
CALICE-CAN-2011-006 (was CAN-034): Analysis of low energetic electron and pion data collected with the AHCAL prototype at Fermilab
CAN-034.tar.gz: gzipped tar file including source and figures for CALICE-CAN-2011-006
CALICE-CAN-2011-009 (was CAN-029): Shower leakage in a highly granular calorimeter
CAN-029.tgz: gzipped tar file including source and figures for CALICE-CAN-2011-009
CALICE-CAN-2013-004 (was CAN-041): Uniformity of the CALICE Fe-AHCAL response to pions
CAN-041.tar.gz: gzipped tar file including source and figures for CALICE-CAN-2013-004
CALICE-CAN-2014-003 (comprises CAN-049 - CAN-049a): Analogue, Digital and Semi-Digital Energy Reconstruction in the CALICE AHCAL
CAN-049.zip: zip file including source and figures for CALICE-CAN-2014-003
CAN-049a.tar.gz: gzipped tar file including source and figures for Addendum A of CALICE-CAN-2014-003
Construction and commissioning of a technological prototype of a high-granularity semi-digital hadronic calorimeter, G. Baulieu et al., JINST 10 (2015) P010039; e-print: arXiv:1506.05316
CALICE-PUB-2019-001: Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models, M. Chefdeville et al., NIM A937 (2019) 41-52; e-print: arXiv:1901.08818
Associated CALICE Analysis Notes :
DHCAL analysis notes
CALICE-CAN-2013-003 (was CAN-042): The DHCAL Results from Fermilab Beam Tests: Calibration
CAN-042.docx: MS Word file including source and figures for CALICE-CAN-2013-003
T3B results
T3B papers
T3B — an experiment to measure the time structure of hadronic showers, F. Simon, C. Solder, L. Weuste; JINST 8 (2013) P12001; e-print: arXiv:1309.6143
The following EUDET note is based on CALICE results from CAN-026.pdf and NIM A608 (2009) 372. The results were reinterpreted into slightly different figures in most cases, but the information content and analysis procedures are unaltered.
Results shown in this note have been approved for public presentation as "CALICE Preliminary".