CERN 2022-06 Combined SiW ECAL 15 SLABs and AHCAL
First test of the full 15 layer stack at CERN, with the full AHCAL.
This page is a copy of
SiWCERN201809.
It can be edited by the members of the
Main.SiWCERN201809Group .
Organisation
Responsabilities & Contacts
Admin
Vincent Boudry +33 6 7131 0577,
SiW -ECAL Contact:
Roman Poeschl +33 6 68 50 16 28 +
Adrián Irles +
Vincent Boudry + Taikan Suehara
AHCAL contacts:
Katja Krueger +
Jiri Kvasnicka
Technical Coordinator:
Adrián Irles +
Jiri Kvasnicka
Shift coordinator:
Vincent Boudry
GLIMOS:
Vincent Boudry +33 6 7131 0577,
Roman Poeschl Katja Krueger
e-group of TB-participants:
CALICE-SIW-ECAL-AHCAL-BT-CERN2022-06@cernNOSPAMPLEASE.ch (
Management link
)
Elog
(not used this time)
Elog
SiWECAL and AHCAL hosted at DESY
For the operation of ECAL, we use the section
https://ttfinfo.desy.de/CALICEelog-sec/show.jsp?dir=/running/ECALrun
Documentation
Admin chore
- CERN Registration procedure:
- Pre-Arrival: Follow step-by-step (1 to 4 at least) on this page: What I need to do
(before arrival)
- Needed documents, Forms, Requested Safety courses. Everything is on that page.
First step: get your documents and ask your group leader to make a Pre-Registration PRT
(the form can be started and shared with the incumbent for easier filling).
⚠ It might take some days for things to get through ⚠
- The proper radio-protection course is the one for the Supervised area (see below).
- Full procedure: User's office procedure for Users and Visiting scientists
- Once registered, you can already ask for access to the Control Room on either:
- 1) EDH
> Access Demand (top line):
- Search by Access point (right, in the middle), and type 887-1-B81
Select the only choice (0887-1-B81 SALTO ), and again (0887-1-B81 Control Room HNA383).
- Give the date of the stay ±1 day (7/6 – 23/6), and the reason (beam test in PPE 172)
- 2) Adams3
- with other information (card validity, etc).
- On arrival: The access card and dosimeter offices are in building 55-R-001 at the entrance.
Opening hours are:7h30–17h30 for the access cards, but 8h30-12:00 for dosimeters.
A valid dosimeter is the key for the beam test area.
- North Area Instructions
Lodging and Mobility
To go to Prevessin, you can:
Take the shuttle:
https://sce-dep.web.cern.ch/cern-shuttle-service
https://sce-dep.web.cern.ch/mobility/shuttle/circuit-5
Rent a bike:
https://sce-dep.web.cern.ch/mobility/bike-rental
Everything is there:
https://sce-dep.web.cern.ch/campus-life/mobility
including the information about the shuttle to/from the airport.
Planning
Admin documents are on the
CERNBOX (use this link to edit docs)
SHIFTS
CERN2022 Shift Instructions to be updated
Materials & Logistics
Talks, proceedings and papers
W.I.P
Commissioning
Data that is necessary for the commissioning is located in the eos folder below.
/eos/project/s/siw-ecal/TB2022-06/commissioning
Slabs commissioned
Layer Position |
SLAB |
SLB- ID |
SLB-Add |
ASU type |
Wafer (μm) |
W (mm) |
0 |
34 |
15 |
0 |
FEV13 |
650 |
4.2 |
1 |
37 |
28 |
1 |
FEV13 |
650 |
4.2 |
2 |
36 |
18 |
2 |
FEV13 |
650 |
4.2 |
4 |
35 |
16 |
3 |
FEV13 |
650 |
4.2 |
3 |
35 |
12 |
4 |
FEV13 |
500 |
4.2 |
5 |
39 |
25 |
5 |
FEV13 |
500 |
4.2 |
6 |
29 |
22 |
6 |
COB |
500 |
4.2 |
7 |
30 |
19 |
7 |
FEV12 |
500 |
4.2 |
8 |
33 |
20 |
8 |
COB |
500 |
4.2 |
9 |
31 |
17 |
9 |
FEV12 |
500 |
5.6 |
10 |
19 |
13 |
10 |
FEV11 |
320 |
5.6 |
11 |
18 |
2 |
11 |
FEV11 |
320 |
5.6 |
12 |
23 |
6 |
12 |
FEV10 |
320 |
5.6 |
13 |
40 |
27 |
13 |
FEV13 |
320 |
5.6 |
14 |
17 |
10 |
14 |
FEV11 |
320 |
5.6 |
(corrected by A. Irles, 10/06/2022)
Passports
Passports are contained in
this file.
Calibration constants (pedestals and MIP)
Calibration files is in the
attachement file. (Taken 03/06/2022)
Pictures of slabs (before installation at CERN)
Taken at 21 Jun at CERN
Full Setup
W.I.P.
Settings
All files (only txt please) to be stored at /eos/project/s/siw-ecal/TB2022-06/calibration/setting_files and/or under the Windows PC in the Setup Folder (please keep them as synchronised as possible)
following the convention there described and updating the README after every time it corresponds.
Shifter Operation
See
https://twiki.cern.ch/twiki/bin/view/CALICE/SiWAHCALCERN202206Shifter
Physics program
Analysis
Analysis page
--
AdrianIrles - 2018-06