From Monday November 12th

ARTDAQ CONFIGURATION FOR RUNS: np04_WibsReal_Ssps_CRT_8Hz_LongWin_00003

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • Run at different Electric fields between 500V/cm and 100V/cm in steps of 50 V/cm. Each run should last at least 60 minutes. Check this spreadsheet for the Catode, Wire bias and field cage termination settings. For each run, fill the AFTER Beam Run list.

  • Keep an eye on the Heinzeinger current plot and in case a current streamer shows up, quickly disable triggers and follow procedures lined out in the shift instructions, and/or wait for instructions from the HV expert. If there is a current streamers and the HV expert doesn't contact you by slack or phone within 10 minutes, call him/her.

  • Keep an eye at the Active FEMBs plot in the Online Monitor - make sure we always have all the FEMBs active.

From Saturday November 10th

ARTDAQ CONFIGURATION FOR BEAM RUNS @ 0.5 GeV/c and 0.3 GeV/c: np04_WibsReal_Ssps_BeamTrig_CRT_00003

ARTDAQ CONFIGURATION FOR BEAM RUNS @ 1 GeV/c: np04_WibsReal_Ssps_BeamTrigLowE_CRT00006

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • Run @ 0.5 GeV/c and 0.3 GeV/c momenta, triggering all particles during beam and triggering with the CRT off-spill. Run @ 1 GeV/c momentum, triggering only hadrons during beam and triggering with the CRT off-spill.So include all elements (WIBs, RCEs, SSPs, CRT, Trig0) in the run. Add 1Hz of fake triggers (unticking the Random option) to the run.

  • Keep an eye on the Heinzeinger current plot and in case a current streamer shows up, quickly disable triggers and follow procedures lined out in the shift instructions, and/or wait for instructions from the HV expert. If there is a current streamers and the HV expert doesn't contact you by slack or phone within 10 minutes, call him/her.

  • Keep an eye on the bottom right plot of the Timing section in the Online Monitor. If dots in the plot accumulates at the edge of the plot (i.e x around 30 seconds) while we are taking beam data, it means we are not writing beam instrumentation information in the data. Stop the run and call the timing expert. More information on the shift instruction Twiki page. An online monitor window with the timing plots open and auto-refresh tab set up is open on the right-most screen on the shifters desks - make sure it's there.

  • Keep an eye at the Active FEMBs plot in the Online Monitor - make sure we always have all the FEMBs active.

  • Don't stop the run for drops on XXDaS component (RCE, Felix, SSP). Quicly stop the run for drops on XXRaS component (RCE, SSP), power cycle the component if necessary, and restart the run.

From Friday November 9th

ARTDAQ CONFIGURATION FOR BEAM RUNS: np04_WibsReal_Ssps_BeamE_CRT_00003

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • Run @ 2 GeV/c momentum, triggering only electrons during beam and triggering with the CRT off-spill. So include all elements (WIBs, RCEs, SSPs, CRT, Trig0) in the run. Add 1Hz of fake triggers (unticking the Random option) to the run.

  • Keep an eye on the Heinzeinger current plot and in case a current streamer shows up, quickly disable triggers and follow procedures lined out in the shift instructions, and/or wait for instructions from the HV expert. If there is a current streamers and the HV expert doesn't contact you by slack or phone within 10 minutes, call him/her.

  • Keep an eye on the bottom right plot of the Timing section in the Online Monitor. If dots in the plot accumulates at the edge of the plot (i.e x around 30 seconds) while we are taking beam data, it means we are not writing beam instrumentation information in the data. Stop the run and call the timing expert. More information on the shift instruction Twiki page. An online monitor window with the timing plots open and auto-refresh tab set up is open on the right-most screen on the shifters desks - make sure it's there.

  • Keep an eye at the Active FEMBs plot in the Online Monitor - make sure we always have all the FEMBs active.

  • Don't stop the run for drops on XXDaS component (RCE, Felix, SSP). Quicly stop the run for drops on XXRaS component (RCE, SSP), power cycle the component if necessary, and restart the run.

From Wednesday November 7th

ARTDAQ CONFIGURATION FOR BEAM RUNS: np04_WibsReal_Ssps_BeamTrig_CRT_00003

ARTDAQ CONFIGURATION FOR PD RUNS: ask Chris

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • Wednesday is beam off day. Cathode HV will be ramped down until one hour before beam comes back, and this time will be used by the PD group for tests. Chris will instruct the shifters about these runs.

  • When beam will be back (6 pm, Wednesday) run @ 1 GeV/c momentum, triggering all particles during beam and triggering with the CRT off-spill. So include all elements (WIBs, RCEs, SSPs, CRT, Trig0) in the run. Add 1Hz of fake triggers (unticking the Random option) to the run.

  • Keep an eye on the Heinzeinger current plot and in case a current streamer shows up, quickly disable triggers and follow procedures lined out in the shift instructions, and/or wait for instructions from the HV expert. If there is a current streamers and the HV expert doesn't contact you by slack or phone within 10 minutes, call him/her.

  • Keep an eye on the bottom right plot of the Timing section in the Online Monitor. If dots in the plot accumulates at the edge of the plot (i.e x around 30 seconds) while we are taking beam data, it means we are not writing beam instrumentation information in the data. Stop the run and call the timing expert. More information on the shift instruction Twiki page. An online monitor window with the timing plots open and auto-refresh tab set up is open on the right-most screen on the shifters desks - make sure it's there.

  • Keep an eye at the Active FEMBs plot in the Online Monitor - make sure we always have all the FEMBs active.

  • Don't stop the run for drops on XXDaS component (RCE, Felix, SSP). Quicly stop the run for drops on XXRaS component (RCE, SSP), power cycle the component if necessary, and restart the run.

From Sunday November 4th

ARTDAQ CONFIGURATION FOR RUNS: np04_WibsReal_Ssps_BeamTrig_CRT_00002

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • Beam run @ 3 GeV/c momentum, triggering all particles during beam and triggering with the CRT off-spill. So include all elements (WIBs, RCEs, SSPs, CRT, Trig0) in the run. Add 1Hz of fake triggers (unticking the Random option) to the run.

  • Keep an eye on the Heinzeinger current plot and in case a current streamer shows up, quickly disable triggers and follow procedures lined out in the shift instructions, and/or wait for instructions from the HV expert. If there is a current streamers and the HV expert doesn't contact you by slack or phone within 10 minutes, call him/her.

  • Keep an eye on the bottom right plot of the Timing section in the Online Monitor. If dots in the plot accumulates at the edge of the plot (i.e x around 30 seconds) while we are taking beam data, it means we are not writing beam instrumentation information in the data. Stop the run and call the timing expert. More information on the shift instruction Twiki page. An online monitor window with the timing plots open and auto-refresh tab set up is open on the right-most screen on the shifters desks - make sure it's there.

  • Keep an eye at the Active FEMBs plot in the Online Monitor - make sure we always have all the FEMBs active.

  • Don't stop the run for drops on XXDaS component (RCE, Felix, SSP). Quicly stop the run for drops on XXRaS component (RCE, SSP), power cycle the component if necessary, and restart the run.

From Thursday November 1st

ARTDAQ CONFIGURATION FOR RUNS: np04_WibsReal_Ssps_BeamTrig_CRT_00002

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • Beam run @ 6 GeV/c momentum, triggering all particles during beam and triggering with the CRT off-spill. So include all elements (WIBs, RCEs, SSPs, CRT, Trig0) in the run. Add 2Hz of fake triggers (unticking the Random option) to the run.

  • Keep an eye on the Heinzeinger current plot and in case a current streamer shows up, quickly disable triggers and follow procedures lined out in the shift instructions, and/or wait for instructions from the HV expert. If there is a current streamers and the HV expert doesn't contact you by slack or phone within 10 minutes, call him/her.

  • Keep an eye on the bottom right plot of the Timing section in the Online Monitor. If dots in the plot accumulates at the edge of the plot (i.e x around 30 seconds) while we are taking beam data, it means we are not writing beam instrumentation information in the data. Stop the run and call the timing expert. More information on the shift instruction Twiki page. An online monitor window with the timing plots open and auto-refresh tab set up is open on the right-most screen on the shifters desks - make sure it's there.

  • Keep an eye at the Active FEMBs plot in the Online Monitor - make sure we always have all the FEMBs active.

  • Don't stop the run for drops on XXDaS component (RCE, Felix, SSP). Quicly stop the run for drops on XXRaS component (RCE, SSP), power cycle the component if necessary, and restart the run.

From Wednesday October 31st

ARTDAQ CONFIGURATION FOR RUNS: np04_WibsReal_Ssps_TrigTest_CRT_00012

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • "Cosmic" type runs, triggering on CRT. Checking long term stability of the whole system. Ok to stop runs for purity measurement or fixing things, or request for different tests.

  • Keep an eye on the Heinzeinger current plot and in case a current streamer shows up, quickly disable triggers and follow procedures lined out in the shift instructions, and/or wait for instructions from the HV expert. If there is a current streamers and the HV expert doesn't contact you by slack or phone within 10 minutes, call him/her.

From Friday October 26th

ARTDAQ CONFIGURATION FOR RUNS:

  • variable

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • series of tests for PD, CRT and trigger system. Configuration to be used and test to be done communicated on an (almost) daily bases.

From Friday October 19th

ARTDAQ CONFIGURATION FOR RUNS:

  • Run in partition_0 and include trigger_0 component
  • np04_WibsReal_Ssps_BeamTrig1GeV_00014
  • Include a 2 Hz fake trigger (unclick Random).

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • Take beam data @ 2 GeV. Check fragments rate and FEMBs in the DQM to make sure we are actually recording data!
  • Monitor of cathode HV voltage and current plots* (look at the shifter instructions to identify the plots to be monitored).
  • In case of current trip, call the HV expert and Run coordinator
  • Keep the DAQ running as much as possible to reduce the time spent starting a run.
    • During beam running if there is an error on the Rack Side that persists for a few minutes stop the run, resolve the problem, then start a new run.
    • During beam running if beam is not delivered for more than 30 minutes stop the run. Start a new run immediately. Keep running when beam arrives.
    • During extended non-beam running start a new run 30 minutes before beam is anticipated to arrive.
    • Always run 2 Hz periodic non-beam trigger.
  • If something doesn't look right and you don't get answers from the Slack channel (especially at night), please use the phone and wake up people! They'll be happy to be awaken to prevent loosing hours of data
  • At the end of each good run with beam (i.e., a run containing at least 5 minutes of beam acquired by the TPC electronics) please record the run number, cathode voltage and beam momentum in this spreadsheet: https://docs.google.com/spreadsheets/d/1O4o9_q8F-KynQltKDAfmco3e_s1eKItFkzZ4-g_Vls0/edit?usp=sharing

  • While we run at 1 GeV and 2 GeV, we'll try to keep the run going as much as possible. So, if you see fragment sizes dropping for SSPs or RCEs on the DAQ side (APA 4,5, and 6), don't worry and keep the run going. On the other side, if it happens on the rack side APAs (APA 1,2 or 3), immediately stop the run and (try) to restart.
  • Occasionally, the cathode current will jump at a higher state (streamer). Generally, it comes back to normal value by itself. sometimes after 5 minutes, sometimes after 5 hours. We decided to don't take action on those for now, just record them. So, if you see the current suddenly jump up, record it in the elog but keep on running. Anyway, if one of the HV experts tells you he/she wants to ramp down the voltage, then unbias the SSPs, stop the run and follow his/her instructions.
  • Ilsoo will run the purity monitor twice per day. So it is ok to stop an ongoing run for that. Anyway, if the purity monitor run can be accommodated during beam off times, or when a run is stop for other reasons, that would be great. If that's not possible, but you can manage to stop the run (because of purity monitor) only after it has been running for at least 2 hours, that would be very much appreciated!

From Wednesday October 17th

ARTDAQ CONFIGURATION FOR RUNS:

  • Run in partition_0 and include trigger_0 component
  • np04_WibsReal_Ssps_BeamTrig1GeV_00010
  • Include a 2 Hz fake trigger (unclick Random).

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • Take beam data @ 1 GeV. Check fragments rate and FEMBs in the DQM to make sure we are actually recording data!
  • Monitor of cathode HV voltage and current plots* (look at the shifter instructions to identify the plots to be monitored).
  • In case of current trip, call the HV expert and Run coordinator
  • Keep the DAQ running as much as possible to reduce the time spent starting a run.
    • During beam running if beam is not delivered for more than 30 minutes stop the run. Start a new run immediately. Keep running when beam arrives.
    • During extended non-beam running start a new run 30 minutes before beam is anticipated to arrive.
    • Always run 2 Hz periodic non-beam trigger.
  • Stop a run when requested by the HV expert during times of cathode HV instability. Resume running once HV is stable and the PD system is powered.

  • As long as we run at 1 GeV and 2 GeV, we'll try to keep the run going as much as possible. So, if you see fragment sizes dropping for SSPs or RCEs on the DAQ side (APA 4,5, and 6), don't worry and keep the run going. On the other side, if it happens on the rack side APAs (APA 1,2 or 3), immediately stop the run and (try) to restart. *Occasionally, the cathode current will jump at a higher state (streamer). Generally, it comes back to normal value by itself. sometimes after 5 minutes, sometimes after 5 hours. We decided to don't take action on those for now, just record them. So, if you see the current suddenly jump up, record it in the elog but keep on running. Anyway, if one of the HV experts tells you he/she wants to ramp down the voltage, then unbias the SSPs, stop the run and follow his/her instructions.
  • Ilsoo will run the purity monitor twice per day. So it is ok to stop an ongoing run for that. Anyway, if the purity monitor run can be accommodated during beam off times, or when a run is stop for other reasons, that would be great. If that's not possible, but you can manage to stop the run (because of purity monitor) only after it has been running for at least 2 hours, that would be very much appreciated!
  • if something doesn't look right and you don't get answers from the Slack channel (especially at night), please use the phone and wake up people! They'll be happy to be awaken to prevent loosing hours of data
  • at the end of each good run with beam (i.e., a run containing at least 5 minutes of beam acquired by the TPC electronics) please record the run number, cathode voltage and beam momentum in this spreadsheet: https://docs.google.com/spreadsheets/d/1O4o9_q8F-KynQltKDAfmco3e_s1eKItFkzZ4-g_Vls0/edit?usp=sharing

From Friday October 12th

ARTDAQ CONFIGURATION FOR RUNS:

  • Run in partition_0 and include trigger_0 component
  • np04_WibsReal_Ssps_BeamTrig1GeV_0009
  • Include a 2 Hz fake trigger (unclick Random).

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • Take beam data @ 1 GeV. Check fragments rate and FEMBs in the DQM to make sure we are actually recording data!
  • Monitor of cathode HV voltage and current plots* (look at the shifter instructions to identify the plots to be monitored).
  • In case of current trip, call the HV expert and Run coordinator
  • If the beam goes away for more than one hour, stop the run and restart a new run keeping the same configuration but changing the Run type from "Physics" to "cosmics". As soon as the beam comes back, stop the run and restart with a "physics" type run.

From Wednesday October 10th

ARTDAQ CONFIGURATION FOR RUNS:

  • Run in partition_0 and include trigger_0 component
  • np04_WibsReal_Ssps_BeamTrig_00023
  • Include a 2 Hz fake trigger (unclick Random).

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_beta

  • Take beam data. Check fragments rate and FEMBs in the DQM to make sure we are actually recording data!
  • Monitor of cathode HV voltage and current plots* (look at the shifter instructions to identify the plots to be monitored).
  • In case of current trip, call the HV expert and Run coordinator
  • If the beam goes away for more than one hour, stop the run and restart a new run keeping the same configuration but changing the Run type from "Physics" to "cosmics". As soon as the beam comes back, stop the run and restart with a "physics" type run.

From Saturday October 6th

ARTDAQ CONFIGURATION FOR COSMIC RUNS:

  • np04_WibsReal_Ssps00133
  • If run in partition_0 then exclude trigger_0 component

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • HV left @ 120 kV. Oil has been added to the cup at the top of the downstream filter (near the HV FT) and it is bubbling. Check that cup every now and then and refill with oil if necessary.
  • Cosmic runs @ 5 Hz with SSPs excluded and monitor of cathode HV voltage and current plots* (look at the shifter instructions to identify the plots to be monitored).
  • In case of current trip, call the HV expert and Run coordinator

From Friday October 5th

ARTDAQ CONFIGURATION FOR COSMIC RUNS:

  • np04_WibsReal_Ssps00133
  • If run in partition_0 then exclude trigger_0 component

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • no shifts on Friday and night between Friday and Saturday due to DAQ and HV tests
  • for Saturday and Sunday, cosmic runs @ 5 Hz with SSPs excluded and monitor of cathode HV voltage and current plots* (look at the shifter instructions to identify the plots to be monitored).

From Wednesday October 3rd

ARTDAQ CONFIGURATION FOR COSMIC RUNS:

  • np04_WibsReal_Ssps00131
  • If run in partition_0 then exclude trigger_0 component

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • Take cosmic run in partition 1 when no specific test is ongoing

  • Check the cathode HV voltage and current plots (look at the shifter instructions to identify the plots to be monitored). Since last night we had an increase in the activity, with current blips/sparks every 10-30 minutes. Most of the blips are ~ 2 microamps high. Occasionally they can be higher, up to 4-6 microamps. Monitor the frequency and height of these spikes. If they become consistently more frequent or much higher, call immediately the HV expert and the Run Coordinator!

  • Upgrade of timing firmware

From Tuesday October 2nd

ARTDAQ CONFIGURATION FOR BEAM RUNS:

  • Run in partition_0 and include trigger_0 component
  • np04_WibsReal_Ssps_BeamTrig_00016
  • np04_WibsReal_Ssps_BeamTrig_4x_prescale_00005 - prescaled for higher rates (i.e. the General trigger value in CESAR > 200 counts)
  • Include a 1 Hz random DAQ trigger

ARTDAQ CONFIGURATION FOR COSMIC RUNS:

  • np04_WibsReal_Ssps00131
  • If run in partition_0 then exclude trigger_0 component

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • Take beam data @ 7 GeV. If beam goes away for an hour or more, switch to cosmic run (remember to select "Physics" as run type in the first case, "cosmic" for the second case)

  • Check the cathode HV voltage and current plots (look at the shifter instructions to identify the plots to be monitored). Since last night we had an increase in the activity, with current blips/sparks every 10-30 minutes. Most of the blips are ~ 2 microamps high. Occasionally they can be higher, up to 4-6 microamps. Monitor the frequency and height of these spikes. If they become consistently more frequent or much higher, call immediately the HV expert and the Run Coordinator!

  • Spot the first event from the beam!

From Friday evening September 28th and weekend

ARTDAQ CONFIGURATION FOR BEAM RUNS:

  • Run in partition_0 and include trigger_0 component
  • np04_WibsReal_Ssps_BeamTrig_00016
  • np04_WibsReal_Ssps_BeamTrig_4x_prescale_00005 - prescaled for higher rates (i.e. the General trigger value in CESAR > 200 counts)

ARTDAQ CONFIGURATION FOR COSMIC RUNS:

  • np04_WibsReal_Ssps00131
  • If run in partition_0 then exclude trigger_0 component

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • Take beam data @ 7 GeV. If beam goes away for an hour or more, switch to cosmic run (remember to select "Physics" as run type in the first case, "cosmic" for the second case)

  • Check the cathode HV voltage and current plots (look at the shifter instructions to identify the plots to be monitored). Since last night we had an increase in the activity, with current blips/sparks every 10-30 minutes. Most of the blips are ~ 2 microamps high. Occasionally they can be higher, up to 4-6 microamps. Monitor the frequency and height of these spikes. If they become consistently more frequent or much higher, call immediately the HV expert and the Run Coordinator!

  • Spot the first event from the beam!

From Friday September 28th

ARTDAQ CONFIGURATION FOR BEAM RUNS:

  • Run in partition_0 and include trigger_0 component
  • np04_WibsReal_Ssps_BeamTrig_00015
  • np04_WibsReal_Ssps_BeamTrig_4x_prescale_00004 - prescaled for higher rates (i.e. the General trigger value in CESAR > 200 counts)

ARTDAQ CONFIGURATION FOR COSMIC RUNS:

  • np04_WibsReal_Ssps00126
  • If run in partition_0 then exclude trigger_0 component

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • During the night between Thursday and Friday take beam runs at the momentum left by Nikos (3 or 4 GeV/c)

  • Beam will be off between 8:30 and 10:30. Time for Chris to use the PD calibration system without CE

  • In the afternoon, take beam data @ 7 GeV/c. Look for parts of beam events start appearing!!!!

  • Check the cathode HV voltage and current plots every now and then -> look at the shifter instructions to identify the plots to be monitored

From Thursday September 27th

ARTDAQ CONFIGURATION FOR BEAM RUNS:

  • Run in partition_0 and include trigger_0 component
  • np04_WibsReal_Ssps_BeamTrig_00015
  • np04_WibsReal_Ssps_BeamTrig_4x_prescale_00004 - prescaled for higher rates (i.e. the General trigger value in CESAR > 200 counts)

ARTDAQ CONFIGURATION FOR COSMIC RUNS:

  • np04_WibsReal_Ssps00126
  • If run in partition_0 then exclude trigger_0 component

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • PD calibration tests done by Chris

  • Test of trigger rates for new configurations done by Nuno @ 3 GeV

  • Beside these tests, take beam data! (or cosmic data when no beam is present)

  • Check the cathode HV voltage and current plots every now and then -> look at the shifter instructions to identify the plots to be monitored

From Wednesday September 26th

ARTDAQ CONFIGURATION FOR COSMIC RUNS:

  • np04_WibsReal_Ssps00125
  • If run in partition_0 then exclude trigger_0 component

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • Before Geoff comes and turns off DAQ, take 5 minutes run using the set of configurations listed in the twiki here "np04_WIBsReal_Ssps_FEMB14mVfC2usPulserXX" where XX is a number between 2 and 50 (there are 17 such configurations). Start with np04_WIBsReal_Ssps_FEMB14mVfC2usPulser2_00007, take a 5 minutes run @ 10 Hz (random trigger), then move to the next configuration np04_WIBsReal_Ssps_FEMB14mVfC2usPulser3_00007, same run time and trigger rate, and so on

* Geoff will come asking to turn off DAQ for computer maintenance, which should last about 2 hours. End the 5 mintues run you're taking and leave it to him

* Once you get DAQ back, resume the 5 minutes runs with the configurations listed above, but use partition 1. Leave partition 0 to Nuno for tests of trigger configurations with the CRT

* Check the cathode HV voltage and current plots every now and then -> look at the shifter instructions to identify the plots to be monitored

From Monday September 24th

ARTDAQ CONFIGURATION FOR COSMIC RUNS:

  • np04_WibsReal_Ssps00125
  • If run in partition_0 then exclude trigger_0 component

ARTDAQ CONFIGURATION FOR BEAM RUNS:

  • Run in partition_0 and include trigger_0 component
  • np04_WibsReal_Ssps_BeamTrig_00012
  • np04_WibsReal_Ssps_BeamTrig_4x_prescale_00003 - prescaled for higher rates (i.e. the General trigger value in CESAR > 200 counts)

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • Take beam runs (remember when you start a run to select "physics" as run type) with full system at 7 GeV. Anyway, there will be tests of the new Cherenkov detector performance done at various energies (3 GeV, 5 GeV, 7 GeV) by the beam group between this evening and tomorrow. They will inform you when they are about to switch to a new beam momentum. When this happen, just stop the current run and immediately restart a new one for the new momentum. Remember to put an entry in the e-log to inform about the momentum change and new run being taken.

  • Monitor the stability of cathode voltage (here) and current (here). Call the HV experts and Run coordinator in case of instabilities.

From Friday September 21st

ARTDAQ CONFIGURATION FOR COSMIC RUNS:

  • np04_WibsReal_Ssps00125
  • If run in partition_0 then exclude trigger_0 component

ARTDAQ CONFIGURATION FOR BEAM RUNS:

  • Run in partition_0 and include trigger_0 component
  • np04_WibsReal_Ssps_BeamTrig_00012
  • np04_WibsReal_Ssps_BeamTrig_4x_prescale_00003 - prescaled for higher rates (i.e. the General trigger value in CESAR > 200 counts) -> For Entire System
  • np04_WibsReal_Ssps_BeamTrig_4x_prescale_00003 - prescaled for higher rates (i.e. the General trigger value in CESAR > 500 counts) -> For ONLY SSPs

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • Take beam runs (remember when you start a run to select "physics" as run type) with SSP only @ all the energies (1 GeV, 2 GeV, 3 GeV, 4 GeV, 5 GeV, 6 GeV, 7 GeV)
  • Take a half an hour cosmic run (remember when you start the run to select "cosmic" as run type) in between each momentum step
  • Monitor the stability of cathode voltage (here) and current (here). Call the HV experts and Run coordinator in case of instabilities.

From Tuesday September 19th

ARTDAQ CONFIGURATION FOR COSMIC RUNS: np04_WibsReal_Ssps00125

ARTDAQ CONFIGURATION FOR BEAM RUNS:

  • Run in partition_0 and include trigger_0 component
  • np04_WibsReal_Ssps_BeamTrig_00019
  • np04_WibsReal_Ssps_BeamTrig_4x_prescale_00002 - prescaled for higher rates

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • Follow HV ramp up (if happening)
  • During technical stop and HV on cathode, take continuous cosmic run with full system on. Remember to select as Run Type "cosmic"
  • During technical stop and HV=0 on cathode, take CE noise runs whenever the system is not used by PD group for calibrations or DAQ experts or BNL group for specific tests. In these days, it would be good to have at least 2 CE noise runs (of at least 15-30 minutes) per day
  • In case of problems, check the troubleshooting section here

From Tuesday September 18th

ARTDAQ CONFIGURATION FOR COSMIC RUNS: np04_WibsReal_Ssps00114

ARTDAQ CONFIGURATION FOR BEAM RUNS: np04_WibsReal_Ssps_BeamTrig_00004 (Run in partition_0 and include trigger_0 component)

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_03_00_alpha

  • Follow HV ramp up (if happening)
  • During technical stop and HV on cathode, take continuous cosmic run with full system on. Remember to select as Run Type "cosmic"
  • During technical stop and HV=0 on cathode, take CE noise runs whenever the system is not used by PD group for calibrations or DAQ experts or BNL group for specific tests. In these days, it would be good to have at least 2 CE noise runs (of at least 15-30 minutes) per day
  • In case of problems, check the troubleshooting section here

From Monday September 17th

ARTDAQ CONFIGURATION FOR COSMIC RUNS: np04_WibsReal_Ssps00113

ARTDAQ CONFIGURATION FOR BEAM RUNS: np04_WibsReal_Ssps_BeamTrig_00001 (Run in partition_0 and include trigger_0 component)

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_02_01_testing

  • Follow HV ramp up
  • During technical stop and HV on cathode, take continuous cosmic run with full system on. Remember to select as Run Type "cosmic"
  • During technical stop and HV=0 on cathode, take CE noise runs whenever the system is not used by PD group for calibrations or DAQ experts or BNL group for specific tests. In these days, it would be good to have at least 2 CE noise runs (of at least 15-30 minutes) per day
  • In case of problems, check the troubleshooting section here

From Thursday August 23rd

ARTDAQ CONFIGURATION FOR NOISE RUNS: np04_WibsReal_Ssps00111

ARTDAQ FOLDER: dune-artdaq_artdaq_v3_02_01_testing

  • Take one CE noise run in the morning and one in the afternoon with 6 APAs, if possible. Check with DAQ experts and PD group for DAQ availability.
  • Take PD commissioning run with 6 APAs.
  • During and anyway before the end of the shift, check data rates, online monitoring, noise levels for the acquired runs.

-- RobertoAcciarri - 2018-08-20

Edit | Attach | Watch | Print version | History: r58 < r57 < r56 < r55 < r54 | Backlinks | Raw View | WYSIWYG | More topic actions