Electromagnetic calorimeter

Hardware effort contact person: ?? (ILD design)

Software implementation: Dan Protopopescu

Supporting material: CLICdp-Note-?

All calorimeters have symmetry 12

Barrel

Material: Tungsten

Readout: Silicon pads (5.1 mm x 5.1 mm)

Structure: 25 layers (17 x 2.4 mm followed by 8 x 4.8 mm)

X0 = 23

λ = 1

inner r = 1500 mm

outer r = 1659 mm

max z = 2250 mm

Endcap

Material: Tungsten

Readout: Silicon pads (5.1 mm x 5.1 mm)

Structure: 25 layers (17 x 2.4 cm followed by 8 x 4.8 cm)

X0 = 23

λ = 1

inner r = 410 mm

outer r = 1700 mm

inner z = 2350 mm

outer z = 2509 mm

Plug

Material: Tungsten

Readout: Silicon pads (5.1 mm x 5.1 mm)

Structure: 25 layers (17 x 2.4 cm followed by 8 x 4.8 cm)

X0 = 23

λ = 1

inner r = 260 mm

outer r = 380 mm

inner z = 2350 mm

outer z = 2509 mm