Trigger Paths for Alignment and Calibration for LHC Run 3 - 2021

Introduction

Trigger bit for special runs

CRAFT - October 2021

AlCaReco vs HLT Paths: https://twiki.cern.ch/twiki/bin/view/CMSPublic/SWGuideAlCaRecoTriggerBits#LastIOVExpress Note: No requests for trigger bits update

Stream Dataset AlCaReco Notes
Physics HLTPhysics HcalCalIsoTrkFilter, HcalCalIterativePhiSym Needed by HCAL unless DoubleEG, JetHT available
Physics MinimumBias HcalCalIsoTrkFilter, HcalCalIterativePhiSym Needed by HCAL unless DoubleEG, JetHT available

BeamTest - October 2021

AlCaReco vs HLT Paths: https://twiki.cern.ch/twiki/bin/view/CMSPublic/SWGuideAlCaRecoTriggerBits#LastIOVExpress Note: No requests for trigger bits update

Stream Dataset AlCaReco Notes
  ZeroBias TkAlMinBias Needed by BeamSpot
  HTPhysics, ZeroBias HcalCalIsoTrkFilter, HcalCalIterativePhiSym Needed by HCAL unless DoubleEG, JetHT available
  MinimumBias HcalCalIsoTrkFilter, HcalCalIterativePhiSym Needed by HCAL unless DoubleEG, JetHT available
Beam test menu to be defined

List of mandatory streams // datasets // paths

Stream Dataset Path Notes
ALCALumiPixelsCountsPrompt AlCaLumiPixelsCountsPrompt AlCa_LumiPixelsCounts_ZeroBias added in https://its.cern.ch/jira/browse/CMSHLT-2164
ALCALumiPixelsCountsExpress AlCaLumiPixelsCountsExpress AlCa_LumiPixelsCounts_Random added in https://its.cern.ch/jira/browse/CMSHLT-2164
ALCAP0 AlCaP0 AlCa_EcalEtaEBonly  
AlCa_EcalEtaEEonly  
AlCa_EcalPi0EBonly  
AlCa_EcalPi0EEonly  
ALCAPHISYM AlCaPhiSym AlCa_EcalPhiSym  
Calibration TestEnablesEcalHcal HLT_EcalCalibration Will change name soon, see https://hypernews.cern.ch/HyperNews/CMS/get/tier0-Ops/1623/1.html
HLT_HcalCalibration Will change name soon, see https://hypernews.cern.ch/HyperNews/CMS/get/tier0-Ops/1623/1.html
DQMCalibration TestEnablesEcalHcalDQM HLT_EcalCalibration  
HLT_HcalCalibration  
EcalCalibration EcalLaser HLT_EcalCalibration  
Express ExpressPhysics HLT_Random  
HLT_ZeroBias  
HLT_ZeroBias_FirstCollisionAfterAbortGap  
HLT_ZeroBias_Alignment  
ExpressAlignment ExpressAlignment HLT_HT300_Beamspot This stream can be added only when tracking can be safely run at HLT.
HLT_ZeroBias_Beamspot This stream can be added only when tracking can be safely run at HLT.
DQMOnlineBeamspot DQMOnlineBeamspot HLT_HT300_Beamspot This stream can be added only when tracking can be safely run at HLT.
HLT_ZeroBias_Beamspot This stream can be added only when tracking can be safely run at HLT.
RPCMON RPCMonitor AlCa_RPCMuonNormalisation  

12 Oct 2021: Following the JIRA https://its.cern.ch/jira/browse/CMSHLT-2164 new streams were defined:

  • ALCALUMIPIXELS replaced by ALCALumiPixelsCountsPrompt
  • ALCALUMIPIXELSEXPRESS replaced by ALCALumiPixelsCountsExpress

Definition of the Express Dataset

Regular Express

Path Rate
HLT_ZeroBias 20 Hz
HLT_Random 10 Hz
HLT_Physics 10 Hz
HLT_ZeroBias_FirstCollisionAfterAbortGap 10 Hz

HLT_ZeroBias_IsolatedBunches and HLT_ZeroBias_Alignment can be dropped for the beam test.
HLT_IsoMu27(24,20) / HLT_Mu17_TrkIsoVVL_Mu8_TrkIsoVVL_DZ / HLT_Ele23_Ele12_CaloIdL_TrackIdL_IsoVL can be dropped for the beam test.
More on JIRA https://its.cern.ch/jira/browse/CMSHLT-2173.

Express Alignment

Path Rate
HLT_HT300_Beamspot 60 Hz
HLT_ZeroBias_Beamspot 60 Hz

HLT_HT450_Beamspot not needed for test beam.
HLT_ZeroBias_Beamspot rate increased from 20 to 60 Hz if PU=0.1 in order to have O(10^2) PVs/LS (see BeamSpot at AlCaDB workshop 2021).
More on JIRA https://its.cern.ch/jira/browse/CMSHLT-2174.

Notice - the rate and paths of Beamspot may depend on the run conditions. For instance, for low pileup / VdM conditions, we could have a lower HT path (usually HT60) and a higher rate of HLT_ZeroBias_Beamspot (up to 60 Hz if the PU is around 0.1, up to 500 Hz if the PU is around 0.01). These are just guidelines - always contact the Beamspot experts!

JIRA tickets

Trigger paths in CondDB

See https://twiki.cern.ch/twiki/bin/view/CMSPublic/SWGuideAlCaRecoTriggerBits

Input from DPGs/POGs

From https://twiki.cern.ch/twiki/bin/view/CMS/AlCaDBHLTSurvey2021 for 2021 AlCaDB workshop

Offline Beamspot [TBC]

ALCARECO Dataset Rate Size
TkAlMinBias ExpressAlignment* 80 Hz (not mentioned)

Pixel Calibration [TBC]

ALCARECO Dataset Rate Size
SiPixelCalZeroBias Express, ExpressCosmics (not mentioned) 2 MB, per lumisection

Tracker Alignment [TBC]

  • No need to give them the split datasets nor the "isolated bunches".

ALCARECO Dataset Rate Size
TkAlMinBias HLTPhysics, Express, Zero 10 Hz (HLTPhysics and Express), 70 Hz (ZeroBias) 150 kB (HLTPhysics, Express), 100 kB (ZeroBias)
TkAlCosmics0T Cosmics, ExpressCosmics 4 Hz 4 kB
TkAlCosmicsInCollisions NoBPTX 0.15 Hz 8 kB
TkAlMuonIsolated SingleMuon 80 Hz 6.4 kB
TkAlZMuMu DoubleMuon 5 Hz 6.5 kB
TkAlUpsilonMuMu MuOnia 1.5 Hz 5 kB
TkAlJpsiMuMu Charmonium 30 Hz 5 kB

Tracker Calibration

  • For detector ageing studies: To be able to monitor this with needed accuracy we’re going to need:
    • 100--150Hz of "SingleX" (X=muon,electron) events for the small bias scans
    • 500Hz of "ZeroBias"-like events for the full scans (SiStripCalMinBias)

ALCARECO Dataset Rate Size
SiStripCalMinBias Express, ZeroBias 30 Hz 500 kB
SiStripCalMinBiasAAG Express 10 Hz 500 kB
SiStripCalZeroBias Express, ZeroBias 10 Hz ZeroBias + 10 Hz Random (Express), 30 Hz (ZeroBias) 250 kB
SiStripPCLHistos Express 10 Hz ZeroBias + 10 Hz Random (Express), 30 Hz (ZeroBias) 250 kB

ECAL

  • Pedestals entered (on October 2017) the Prompt Calibration Loop
  • Plan to have also pulse-shapes / timing at PCL for 2018

ALCARECO Dataset Rate Size
EcalCalPhiSym /AlCaPhiSym/*/RAW 3 kHz 1.5 kB
EcalCalPi0Calib /AlCaP0/*/RAW 6 kHz (EB), 2 kHz (EE) 1.6 kB
EcalCalEtaCalib /AlCaP0/*/RAW 2 kHz (EB), 300 kHz (EE) 1.6 kB
EcalUncalZElectron /DoubleEG/*EcalUncalZElectron*/ALCARECO 5.6 Hz 0.2 kB
EcalUncalZElectron /SingleElectron/*EcalUncalZElectron*/ALCARECO 8 Hz 0.2 kB
EcalUncalWElectron /DoubleEG/*EcalUncalWElectron*/ALCARECO 3 Hz 0.2 kB
EcalUncalWElectron /SingleElectron/*EcalUncalWElectron*/ALCARECO 40 Hz 0.2 kB
EcalESAlign /SingleElectron/*EcalESAlign*/ALCARECO 90 Hz 50 kB
  • 2018-05-04: Fixed typo in size of EcalESAlign (0.1 or 1 kB --> 50 kB)

HCAL

  • HF and HO will be essentially unchanged from 2017 to 2018
  • For HE, the photodetectors and front-end electronics are upgraded:
    • HPD -> SiPM, up-to-3 depths -> up-to-7 depths
  • For HB & HE, reco algorithm will be upgraded from M2 to MAHI for offline
    • For HLT, transition to MAHI with full depth is still needed to be discussed

ALCARECO Dataset Rate Size
HcalCalIsoTrk /Commissioning 3.5 Hz 1.5 MB
HcalCalIsoTrkFilter /DoubleEG , /Jet/HT 7 Hz (DoubleEG), 10 Hz (JetHT) 1.7 MB
HcalCalIsolatedBunchSelector /Commissioning Active only for special runs with isol. bunches, 100 Hz --
HcalCalIsolatedBunchFilter /JetHT Active only for special runs with isol. bunches, 100 Hz --
HcalCalIterativePhiSym /DoubleEG, /SingleElectron, /SingleMuon 70 Hz (DoubleEG), 115 Hz (SingleElectron), 245 Hz (SingleMuon) 90 kB
HcalCalMinBias /HcalNZS 8--10 Hz 25 kB
HcalCalHBHEMuonFilter /SingleMuon 90 Hz 900 kB
HcalCalHO /SingleMuon 240 Hz 1 kB
  • 2018-05-04: Fixed typo in size of HcalCalHBHEMuonFilter (90 --> 900 kB)

Muon Alignment [TBC]

ALCARECO Dataset Rate Size
MuAlCalIsolatedMu SingleMuon 25 Hz 50 kB

Muon Subsystems

ALCARECO Dataset Rate Size
DtCalib Express, Single Muon 3 Hz (not mentioned)
DtCalibCosmics ExpressCosmics 3 Hz (not mentioned)
N/A RPCMON 400 Hz 26 kB

LUMI and BRIL [TBC]

ALCARECO Dataset Rate Size
AlCaPCCRandom AlCaLumiPixels 1600 Hz (ZeroBias), 400 Hz (Random) 150 B (ZeroBias), 300 B (Random)
LumiPixelsMinBias Express ??? ???

TSG documentation for L1/HLT menus

Tier-0 information

Edit | Attach | Watch | Print version | History: r9 < r8 < r7 < r6 < r5 | Backlinks | Raw View | WYSIWYG | More topic actions
Topic revision: r9 - 2021-10-18 - FrancescoBrivio
 