Tau L1 Commissioning and HLT DQM

Complete: 1

Contacts

  • Contact persons: Mike Bachtis, Konstantinos Petridis

Tau DQM

The Data Quality Monitoring for Tau HLT goal is to provide code for online/offline monitoring of Tau HLT performance in data coming from the detector. It is split into Online DQM which runs on a stream with rate ~ 1 Hz and Offline DQM. The Offline DQM is executed at the end of the run after prompt reconstruction. In online DQM a set of backup triggers is utilized to evaluate efficiencies and quality tests.For offline DQM, the plan is to compare to offline Objects (PFTaus,CaloTaus,Electrons, etc) to get a first look on the efficiency and the fake rate of the triggers

How to run the Online DQM code

Create a new area:

scramv1 p CMSSW CMSSW_2_1_0_pre6

cd CMSSW_2_1_0_pre6/src

Download the code:

cvs co -r V03-00-29 DQM/HLTEvF

Build it:

scramv1 b

Copy a config file that runs with the backup table:

cp ~bachtis/public/RunHLTDQM.cfg .

or get it from here RunHLTDQM.cfg

Run it:

cmsRun RunHLTDQM.cfg

The default config file redirects the output to a GUI installed on pcwiscms10.cern.ch To access the output enter in the browser: http://pcwiscms10:8030/dqm/online For access outside CERN you need the standard tunelling.

Note: If you plan to use the GUI to run and monitor long jobs it is better to change the DQMFolder name. The reason for this is that if a lot of jobs send histograms with the same name to the same folder the GUI might crash. To avoid this edit the config file DQM/HLTEvF/data/HLTMonTau.cfi and replace

DQMFolder      =    "HLT/HLTTAU" with

DQMFolder      =    "HLTYourname/HLTTAU"

Remember to do it for all Tau paths in the file ..

How to run the Offline DQM code

Create a new area:

scramv1 p CMSSW CMSSW_2_1_0_pre6

cd CMSSW_2_1_0_pre6/src

Download the code:

cvs co -r V03-02-02 DQMOffline/Trigger

Build it:

scramv1 b

Run on QQH:

cd DQMOffline/Trigger/test

cmsRun HLTTauOfflineDQMTest_cfg.py

regarding the GUI And monitoring of the plots while it runs ,

same things apply as the Online DQM

MC Samples for DQM tests

/RelValZEE/CMSSW_2_1_0_pre6-RelVal-1213921089-STARTUP_V1-2nd/GEN-SIM-DIGI-RAW-HLTDEBUG-RECO

/RelValZTT/CMSSW_2_1_0_pre6-RelVal-1213921089-STARTUP_V1-2nd/GEN-SIM-DIGI-RAW-HLTDEBUG-RECO

/RelValQCD_Pt_50_80/CMSSW_2_1_0_pre6-RelVal-1214239099-STARTUP_V1-2nd/GEN-SIM-DIGI-RAW-HLTDEBUG-RECO

/RelValQCD_Pt_80_120/CMSSW_2_1_0_pre6-RelVal-1213987236-IDEAL_V2-2nd/GEN-SIM-DIGI-RAW-HLTDEBUG-RECO

L1 CRUZET data Analysis

How to run the code

Samples to be used

Latest results

Title SandBox

Area in free format for items that the groups wish to add: meetings, to do lists, links etc

Review status

Reviewer/Editor and Date (copy from screen) Comments
KatiLassilaPerini - 23 Jan 2007 created template page

Responsible: ResponsibleIndividual
Last reviewed by: Most recent reviewer

Topic attachments
I Attachment History Action Size Date WhoSorted ascending Comment
Unknown file formatcfg RunHLTDQM.cfg r1 manage 631.9 K 2008-07-07 - 14:52 MichailBachtis  

This topic: CMSPublic > CMSCommunicationsGroup > CMSCommunicationsProjects > WebHome > SWGuide > SWGuideContributors > SWGuideTauDQM
Topic revision: r7 - 2011-02-07 - MatthiasEdelhoff
 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright & 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback