Tracker Material Budget plots

The material budget simulation of the CMS Tracker featuring the Phase 1 Pixel detector is presented. Shown is the breakdown of the total material budget into sub-detectors (TEC, TOB, TIB and TID and Pixel Phase 1). The beam pipe and support tube are also included in the material budget. 100,000 single neutrino gun events are used to compile the plots. The passage of the neutrino through the material of the simulated CMS detector is tracked in Geant4, imaging the material distribution of the detector by plotting, for each step of the neutrino's spatial trajectory, the fraction of the total radiation or hadronic interaction length of its trajectory, traversed in that step.

Phase 0

Phase 1

Contacts: Marco.Musich@cernNOSPAMPLEASE.ch, Tatjana.Susa@cernNOSPAMPLEASE.ch, Raechel.Bartek@cernNOSPAMPLEASE.ch

Material Budget - Radiation Length, Tracker Phase 1 Material Budget - Hadronic Interaction Length, Tracker Phase 1

Figure: Material budget in number radiation lengths (x/X0, right) of and hadronic interaction length (x/λ0, left) as a function of the pseudorapidity η. The contribution of the support tube (light gray), the beam pipe (dark gray), and sub-detectors: TOB (red), Pixel Phase 1 (blue), TEC (yellow) and TID+TIB (magenta) are stacked.

Topic attachments
I Attachment History Action Size Date Who Comment
PNGpng EtaPhiMap_lambdaI.png r1 manage 96.1 K 2012-10-19 - 10:30 SandroGonzi Material budget η-φ map of the CMS tracker in units of hadronic interaction lengths λI
PNGpng EtaPhiMap_x0.png r1 manage 91.6 K 2012-10-19 - 10:31 SandroGonzi Material budget η-φ map of the CMS tracker in units of radiation length X0
PNGpng MaterialBudgetTrackerPhase1_FractionRadiationLength.png r2 r1 manage 284.4 K 2020-07-21 - 00:51 AndresVargasHernandez Material Budget for Tracker Phase 1
PNGpng MaterialBudgetTrackerPhase1_HadronicInteractionLengthFraction.png r1 manage 302.3 K 2020-07-21 - 00:50 AndresVargasHernandez Material Budget for Tracker Phase 1
PNGpng Tracker_SubDetectors_l_vs_eta.png r1 manage 32.6 K 2012-10-08 - 12:31 SandroGonzi Material budget of the CMS tracker in units of hadronic interaction lengths λI
PNGpng Tracker_SubDetectors_x_vs_eta.png r1 manage 30.1 K 2012-10-08 - 12:38 SandroGonzi Material budget of the CMS tracker in units of radiation length X0
Edit | Attach | Watch | Print version | History: r13 < r12 < r11 < r10 < r9 | Backlinks | Raw View | WYSIWYG | More topic actions
Topic revision: r13 - 2020-09-16 - MarcoMusich
 
    • Cern Search Icon Cern Search
    • TWiki Search Icon TWiki Search
    • Google Search Icon Google Search

    CMSPublic All webs login

This site is powered by the TWiki collaboration platform Powered by PerlCopyright & 2008-2023 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
or Ideas, requests, problems regarding TWiki? use Discourse or Send feedback