Instruments at Cloud in 2009

Computer node of the Instrument

Instrument DAQ Responsable Oper. System DAQ System Comments
Sample analyser
PTR-MS Axel Metzger WINDOWS XP Pfeiffer Vakuum software(QUADSTAR) none
O3 analyser Axel Metzger WINDOWS ? Need to be done at CERN none
SO2 analyser Jonathan Duplissy WINDOWS ? Need to be done at CERN instrument arrive June 10th
Dew point sensors Frank Stratmann ? ? Program need to be done
MSANC Agnieszka LINUX FEDORA 11 Acquire (development at Uni. Vienna) Experimental results will be delivered after evaluation
NAIS [[mailto:mikko.sipila@helsnki.fi][Mikko Sipilä] ? ?? none
W-tof-MS Siegfried Schobesberger Windows XP Tofwerkl software huge amount of data
CIMS Andreas Kuerten Linux / Debian C Program none
CCNC Georgios WINDOWS ? ? 2010
expansion CPC Daniela WINDOWS XP LABVIEW 8.6 none
CPC battery Guenther and Francesco WINDOWS XP LABVIEW 8.5 none
SMPS Guenther and Francesco WINDOWS XP LABVIEW 8.5 none
Gerdien Alessandro Windows ? in development, probably Labview in development
Chamber Intrumentation and system
UV sensor Paulo Pereira LINUX PAIPIX(to confirm) C PROGRAM(to confirm) none
Thermometers Michael Guinchard WINDOWS XP LABVIEW (to confirm) Ready by end of June
Fieldcage HV Joachim Beachler ? ? Ready begining of June
Gas system Stefan Haider WINDOWS XP PROF. PVSS none
Mixing fans Pierre Minginette WINDOWS XP need to choose to be combined with HV computer
UV lamp Paulo Pereira ? ? none
Expansion system Stefan Haider ? ? 2010
Thermal control Robert Kristic ? ? 2010
CERN PS/T11 beam
Beam
GCR monitor Sergey Mizin Windows XP Borland C++ need to provide computer?
Beam hodoscope Sergey Mizin Windows XP Borland C++ need to provide computer?

Data to send to the Central DAQ

Instrument data type data aquisition period data rate data format Comments
Sample analyser
PTR-MS Spectra (Complex) 180s\30s ~1000b/s ascii file none
O3 analyser Simple Values 1s ? ? none
MSANC Set of values Variable, depending on experimental need External (visible to CLOUD): about 1.5kB/min; Internal: about 40MB/min Paulo has an example Experimental results will be delivered after evaluation
Dew point sensors Simple Values ? ? ? none
NAIS Spectra (Complex) .5s 900b/s ascii file none
W-tof-MS Spectra(Complex) 5 s (standard) 1500-4500 b/s @ 5 s mode binary file none
CIMS Mass spectra typically 1 s ~100 byte / s ascii file (need example) none
CCNC 2010
SO2 analyser Simple Values 1s ? ? none
expansion CPC Particle Number Concentrations 5s 100 kbyte / 5 s ascii file (need example) none
CPC battery Simple Values 2s ~100b/s ascii file none
SMPS Spectra(Complex) ~5min ~785b/5min ascii files none
Gerdien ? ? ? ? Under development
Chamber Intrumentation and system
UV sensor Simple Values ? ? ? Under development
Thermometers Simple Values 1s ? ascii file(example end of june) none
Fieldcage HV Simple Values ? ? ? Under development
Gas system Simple Values 1s ? DIP interface none
Expansion system ? ? ? ? 2010
Thermal control ? ? ? ? 2010
Mixing fans ? ? ? ? Under development
UV lamp ? ? ? ? Under development
CERN PS/T11 beam
Beam Simple Values ? ? DIP interface none
GCR monitor Simple Values 1s 164b/s ascii file none
Beam hodoscope Simple Values 1s 164b/s ascii file none

Time stamping

Instrument Time stamping make in time stamp definition Period of integration Syncronazible by NTP Comments
Sample analyser
Example Instrument or Computer? which part of time interval begining,middle, end, live 5s, 2 nmin yes or no if question ask Paulo pjsp@cernNOSPAMPLEASE.ch
PTR-MS
O3 analyser Computer live none yes once the instrument arrive this could be improve
SO2 analyser Computer live none yes once the instrument arrive this could be improve
Dew point sensors Computer live none yes once the instrument arrive this could be improve
MSANC Computer Sampling interval, variable values given in resulting set of data, details see discussion Variable Yes none
NAIS ? ? ? ? none
W-tof-MS Computer Begining 5s (standard) Yes none
CIMS Computer time at which representative value is taken typically 1 s Yes none
CCNC ? ? ? ? 2010
expansion CPC Computer time at which representative value is taken ~5s Yes none
CPC battery Computer ? ? ? none
SMPS Computer ? 3 min yes none
Gerdien ? ? ? ? Under development
Chamber Intrumentation and system
UV sensor ? ? ? ? Under development
Thermometers Computer Reading voltage output none yes none
Fieldcage HV ? ? ? ? Under development
Gas system ? ? ? ? none
Mixing fans ? ? ? ? Under development
UV lamp ? ? ? ? Under development
Expansion system ? ? ? ? 2010
Thermal control ? ? ? ? 2010
CERN PS/T11 beam
Beam ? ? ? ? none
GCR monitor ? ? ? ? none
Beam hodoscope ? ? ? ? none

-- PauloPereira - 12-Oct-2009

Edit | Attach | Watch | Print version | History: r1 | Backlinks | Raw View | WYSIWYG | More topic actions
Topic revision: r1 - 2009-10-12 - unknown
 
    • Cern Search Icon Cern Search
    • TWiki Search Icon TWiki Search
    • Google Search Icon Google Search

    Cloud All webs login

This site is powered by the TWiki collaboration platform Powered by PerlCopyright &© 2008-2023 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
or Ideas, requests, problems regarding TWiki? use Discourse or Send feedback