Electron Energy Scan in Tower 0 (SiPM)
- Calorimeter rotated by 1°
- SiPM filters: Kodak Wratten 3 in scintillation channel, transparent one in Cherenkov
- SiPM majority = 3
- PMT yellow filter on scintillation channels, no amplification in Cherenkov
Energy |
Run # |
N. Event |
Comments |
(GeV) |
|
(x1000) |
|
6 |
696 |
31 |
|
6 |
697 |
1 |
|
6 |
700 |
3 |
|
|
|
|
10 |
655 |
27 |
|
10 |
656 |
2 |
|
10 |
657 |
50 |
|
|
|
|
20 |
648 |
150 |
no C counters |
20 |
670 |
100 |
|
20 |
694 |
100 |
|
20 |
695 |
100 |
no Preshower |
|
|
|
30 |
649 |
57 |
no C counters |
30 |
651 |
15 |
no C counters |
30 |
652 |
100 |
|
30 |
671 |
100 |
|
30 |
693 |
100 |
|
|
|
|
|
40 |
645 |
150 |
no C counters |
40 |
669 |
500 |
|
40 |
686 |
500 |
|
40 |
687 |
520 |
|
|
|
|
60 |
644 |
150 |
no C counters |
60 |
672 |
100 |
|
60 |
692 |
100 |
|
60 |
722 |
100 |
Pb target used (estimated electron fraction ~ 1.5%) - wrong pressure in C counters |
60 |
723 |
120 |
Pb target used (estimated electron fraction ~ 1.5%) |
60 |
724 |
80 |
Pb target used (estimated electron fraction ~ 1.5%) |
60 |
725 |
80 |
Pb target used (estimated electron fraction ~ 1.5%) |
60 |
729 |
123 |
Pb target |
|
|
|
80 |
646 |
150 |
no C counters |
80 |
673 |
100 |
|
80 |
691 |
100 |
|
80 |
718 |
100 |
Pb target used (estimated electron fraction ~ 1.8%) |
80 |
719 |
100 |
Pb target used (estimated electron fraction ~ 1.8%) |
80 |
726 |
150 |
Pb target used |
80 |
728 |
150 |
Pb target used |
|
|
|
100 |
653 |
300 |
|
100 |
674 |
100 |
there may be a problem with data misalignment! |
100 |
716 |
100 |
Pb target used (estimated electron fraction ~ 1%) |
100 |
717 |
100 |
Pb target used (estimated electron fraction ~ 1%) |
100 |
727 |
300 |
Pb target used |
|
|
|
125 |
647 |
150 |
no C counters |
125 |
654 |
150 |
|
125 |
675 |
100 |
|
125 |
715 |
20 |
new beam conf |
Special Runs
These are special electron runs where the configuration is different from beam in central tower
Tower |
Energy (GeV) |
*Run Number" |
N. Event (x1000) |
Comments |
1 |
10 |
688 |
50 |
|
1 |
60 |
689 |
50 |
C pressure ~ 45 mbar |
1 |
100 |
690 |
50 |
C pressure ~ 20 mbar |
5 |
60 |
722 |
5 |
Pb target used (estimated electron fraction ~ 1.5%) |
4 |
20 |
740 |
5 |
Cu + Al target (standard, runs with no comments have been taken with this target) |
4 |
20 |
741 |
5 |
Graphite target |
4 |
10 |
742 |
5 |
Pb-6+Al-400 target |
0 |
20 |
741 |
5 |
Pb-6+Al-400 target ; Spectroscopy + timing |
0 |
20 |
741 |
6 |
Pb-6+Al-400 target ; Only Spectroscopy |
Muon scan
- Yellow filters (Kodak Wratten #3) in the S channels
Tower |
Energy (GeV) |
*Run Number" |
N. Event (x1000) |
Comments |
0 |
180 (max momentum) |
682 |
100 |
Majority threshold set to 1 |
0 |
180 (max momentum) |
683 |
100 |
Majority threshold set to 3 (same as electron runs) |
0 |
180 (max momentum) |
702 |
22 |
Majority threshold set to 3 (same as electron runs) |
1 |
180 (max momentum) |
703 |
20 |
Majority threshold set to 1 |
2 |
180 (max momentum) |
704 |
20 |
Majority threshold set to 1 |
3 |
180 (max momentum) |
706 |
20 |
Majority threshold set to 1 |
5 |
180 (max momentum) |
730 |
20 |
Majority threshold set to 1 |
8 |
180 (max momentum) |
731 |
20 |
Majority threshold set to 1 |
7 |
180 (max momentum) |
732 |
20 |
Majority threshold set to 1 |
6 |
180 (max momentum) |
734 |
20 |
Majority threshold set to 1 |
4 |
180 (max momentum) |
735 |
33 |
Majority threshold set to 1 |
- Orange filters (Kodak Wratten #21) in the S channels
Tower |
Energy (GeV) |
Run # PMT |
Run # SiPM |
N. Event |
Comments |
0 |
180 (wide band) |
576 |
576 |
22.5 k |
|
0 |
180 (wide band) |
578 |
578 |
105 k |
Board 0 not working properly - Trigger ID problems |
0 |
180 (wide band) |
581 |
581 |
13 k |
T-OR sent to TDC |
0 |
180 (wide band) |
582 |
582 |
5 k |
Run interrupted during night |
5 |
180 |
638 |
638 |
50 k |
|
0 |
180 |
639 |
639 |
10 k |
|
Calibration runs for PMT and Energy scan with Orange Filter
*
Yellow filters (Kodak Wratten #3) in the S channels
Tower |
Energy (GeV) |
Run # PMT |
Run # SiPM |
N. Event (x1000) |
Comments |
1 |
20 |
660 |
660 |
30 |
PMT calibration |
2 |
20 |
661 |
661 |
25 |
PMT calibration , dropped because problem in LINAC 4 |
2 |
20 |
662 |
662 |
34 |
PMT calibration |
3 |
20 |
663 |
663 |
36 |
PMT calibration |
5 |
20 |
664 |
664 |
30 |
PMT calibration |
8 |
20 |
665 |
665 |
33 |
PMT calibration |
7 |
20 |
666 |
666 |
34 |
PMT calibration |
6 |
20 |
667 |
667 |
32 |
PMT calibration |
4 |
20 |
668 |
668 |
33 |
PMT calibration |
- Setup with Orange filters (Kodak Wratten #21) in the S channels, both PMTs and SiPM (please bear in mind all runs in the energy scan list have been taken with the Kodak Wratten #3 filter)
Tower |
Energy (GeV) |
Run # PMT |
Run # SiPM |
N. Event |
Comments |
5 |
y |
607 |
607 |
7 k |
PMT calibration |
8 |
y |
611 |
611 |
11 k |
PMT calibration |
7 |
y |
613 |
613 |
11 k |
PMT calibration |
6 |
y |
614 |
614 |
11 k |
PMT calibration |
4 |
y |
615 |
615 |
11 k |
PMT calibration |
1 |
y |
618 |
618 |
11 k |
PMT calibration |
2 |
y |
624 |
624 |
12 k |
PMT calibration |
3 |
y |
626 |
626 |
12 k |
PMT calibration |
0 |
60 |
627 |
627 |
100 k |
|
0 |
80 |
628 |
628 |
50 k |
|
0 |
125 |
629 |
629 |
50 k |
|
0 |
100 |
630 |
630 |
50 k |
|
0 |
40 |
631 |
631 |
50 k |
|
0 |
30 |
632 |
632 |
50 k |
|
0 |
20 |
637 |
637 |
100 k |
Busy signal reconnected - TDC resolution: 140 ps |
Position scan
- Nominal electron beam, 40 GeV, Cherenkov counter threshold 80 mbar
x |
y |
Run Number |
N. Event (x1000) |
Comments |
-30 |
-19 |
676 |
50 |
left side of T0 along x, centre along y |
-30 |
-1 |
677 |
50 |
left side of T0 along x, bottom along y |
+6 |
-1 |
678 |
50 |
right side of T0 along x, bottom along y |
+6 |
-19 |
679 |
20 |
right side of T0 along x, centre along y |
+6 |
-19 |
680 |
20 |
right side of T0 along x, centre along y |