Naming conventions
Overall test beam setup
Tracker layer
Scintillator/Calorimeter mapping
Det. channel |
Det. SN |
PMT SN |
HV cable |
HV channel |
Signal cable |
PP channel |
Digitizer channel |
Calo module 0 |
2 |
LB7870 |
HV1 |
CH0 (Calo CH0) |
FASER Signal 1 |
TBA |
Channel 0 |
Calo module 1 |
1 |
LB8755 |
HV2 |
CH1 (Calo CH1) |
FASER Signal 2 |
TBA |
Channel 1 |
Calo module 2 |
4 |
LB8732 |
HV3 |
CH2 (Calo CH2) |
FASER Signal 3 |
TBA |
Channel 2 |
Calo module 3 |
6 |
LB7886 |
HV4 |
CH3 (Calo CH3) |
FASER Signal 4 |
TBA |
Channel 3 |
Calo module 4 |
5 |
LB8733 |
HV5 |
CH4 (Veto1 CH0) |
FASER Signal 5 |
TBA |
Channel 4 |
Calo module 5 |
8 |
LB8758 |
HV6 |
CH5 (Veto1 CH1) |
FASER Signal 6 |
TBA |
Channel 5 |
Preshower layer 0 |
Scint 1 |
TBA |
TBA 0 |
CH12 (Preshower CH0) |
BNC 0 |
TBA |
Channel 6 |
Preshower layer 1 |
Scint 2 |
TBA |
TBA 1 |
CH13 (Preshower CH1) |
BNC 1 |
TBA |
Channel 7 |
Trigger layer 0 |
TBA |
EA0117 |
TBA 2 |
CH6 (Veto2 CH0) |
BNC 2 |
TBA |
Channel 8 |
Trigger layer 1 |
TBA |
EA0118 |
TBA 3 |
CH7 (Veto2 CH1) |
BNC 3 |
TBA |
Channel 9 |
Tracker mapping
TBA
Trigger Mapping and Thresholds
Trigger configuration in digitizer/trigger input (delays and thresholds TBC):
Trigger Line |
Input |
Threshold |
Input delay |
0 |
Calo 0 OR Calo 1 |
5 mV |
1 BC |
1 |
Calo 2 OR Calo 3 |
5 mV |
1 BC |
2 |
Calo 4 OR Calo 5 |
5 mV |
1 BC |
3 |
Preshower 0 AND Preshower 1 |
25 mV |
0 BC |
4 |
Trigger 0 AND Trigger 1 |
25 mV |
1 BC |
Trigger items configured in TLB - only item 2 should be enabled in normal running:
Trigger Item |
Input |
Comment |
0 |
IN0 OR IN1 OR IN2 |
Any calorimeter hit |
1 |
IN3 |
Preshower hit |
2 |
IN4 |
Trigger layer hit |
3 |
IN3 AND IN4 |
Trigger and Preshower hit |
4 |
Random trigger |
Set to 10 Hz |
5 |
LED calibration |
Set to 10 Hz |
--
BrianPetersen - 2021-07-24