Test on electron forward scattering from foils at 13 MeV
Main authors:
B. Faddegon,
J. Ramos-Méndez University of California San Francisco, US.
Short description: A mono-energetic electron beam of 13
MeV and Gaussian circular spot of 0.1 cm FWHM was normally incident on the exit window, a scattering foil, a monitor chamber, and mylar slabs on either side of a region filled with helium
Reference publication: Bruce A Faddegon, Iwan Kawrakow, Yuri Kubyshin, Joseph Perl, Josep Sempau, and Laszlo Urban, “The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for simulation of electron scatter in external beam radiotherapy,” Phys. Med. Biol. 54:6151-6163, 2009.
Geant-val layout:
ElecForwScat
Tested EM physics constructors:
- EMStandard_opt0
- EMStandard_opt3
- EMStandard_opt4
- EmStandard_GS
- Livermore
- Penelope
--
SusannaGuatelli - 2019-04-18