Welcome to the Twiki web page of the G4MSBG initiative: G4-Med

Purpose

The aim of the Geant4 Medical Physics Benchmarking Group (G4MSBG) is to develop a fully automatised Geant4 benchmarking and regression testing system for medical physics applications, called G4-Med. A set of Geant4 Physics Constructors and Lists of interest for medical physics applications are tested. The tests are integrated in the geant-val test system to be executed for benchmarking and regression testing. The test are executed using the CERN computing infrastructure.

List of current tests

Currently the G4-Med system includes 18 tests.

Test geant-val layout Authors
Photon attenuation coefficients PhotonAttenuation S. Guatelli, L. Pandola
Electron stopping powers ElectronDEDX V. Ivanchenko
Low energy electron backscattering ElectronBackScat P. Dondero, A. Mantero,V. Ivanchenko, M. Novak
Electron scattering from foils at 13-20 MeV kinetic energies ElecForwScat B. Faddegon, J. Ramos-Méndez
Bremsstrahlung yield Bremsstrahlung B. Faddegon,J. Ramos-Méndez
Fano cavity Fano cavity P. Arce , M. Maire, M. Novak
Electron Dose Point Kernel LowEElecDPK S. Incerti, M.-C. Bordage, I. Kyriakou, Y. Perrot
Microdosimetry Microyz S. Incerti, I. Kyriakou
Brachytherapy - dose rate Brachy-ir S. Guatelli, D. Cutajar
Dosimetry - clinical 5-6 MeV electron beam To be added L. Desorgher
Dosimetry for mammography Mammo C. Fedon, I. Sechopoulos
Hadronic nucleus-nucleus inelastic cross section NucNucInelXS D. Sakata, S. Guatelli, E. Simpson
Bragg curves in water for 67.5 MeV protons LowEProtonBraggPeak B. Faddegon, J. Ramos-Méndez
Absolute neutron yield for protons ProtonC12NeutronYield B. Faddegon, J. Ramos-Méndez
Production cross sections of different fragments C12FragCC C. Omachi, T. Toshito, T. Sasaki
62 MeV /n C-12 fragmentation on Carbon target LowEC12Frag C. Mancini-Terracciano
400 MeV/n C-12 fragmentation C12Frag D. Bolst, S. Guatelli, F. Romano
Estimation of proton radiobiological damage LowEProtonRBE G. Petringa, GAP Cirrone L. Pandola, G. Cuttone
Light ion (proton, 3He, carbon) range and depth dose curves in water LightIonBraggPeak M. Cortes-Giraldo, A. Perales, J. M. Quesada Molina

Development of the benchmarking/regression system

Collaborators

Coordinator: S. Guatelli (University of Wollongong, Wollongong, Australia), e-mail: susanna@uowNOSPAMPLEASE.edu.au

Deputy Coordinator: P. Arce (CIEMAT,Madrid, Spain), e-mail: pedro.arce@ciematNOSPAMPLEASE.es

Mailing list: geant4-medical-bench@cernNOSPAMPLEASE.ch . alias: geant4-med@cernNOSPAMPLEASE.ch

Collaborators list

CollaboratorsSorted descending Institute
Y. Perrot IRSN, France
V. Ivanchenko Tomsk State University, Tomsk, Russian Federation
T. Toshito Nagoya Proton Therapy Center, Nagoya, Japan
T. Sasaki KEK, Tsukuba, Japan
S. Incerti CENBG, Bordeaux, France
S. Guatelli University of Wollongong, Wollongong, Australia
Pedro Arce CIEMAT, Madrid, Spain
P. Dondero SWHARD srl, Genova, Italy
P. Cirrone INFN Catania, Catania, Italy
M.-C. Bordage CRCT (INSERM and Paul Sabatier University), Toulouse, France
M. Novak CERN, Geneva, Switzerland
M. Maire LAPP, IN2P3, Annecy, France
M. Cortes-Giraldo Universidad de Sevilla, Sevilla, Spain
L. Sarmiento Lund University, Lund, Sweden
L. Pandola INFN Gran Sasso, Gran Sasso, Italy
L. Desorgher Radiophysics Institute, Lausanne, Switzerland
J. Ramos-Méndez University of California, San Francisco, US
J. M. Quesada Molina Universidad de Sevilla, Sevilla, Spain
I. Sechopoulos Radboud University Medical Center, Nijmegen, The Netherlands
I. Kyriakou Ioannina University, Ioannina, Greece
G. Petringa INFN Catania, Italy
G. Latyshev IHEP, Protvino, Russian Federation
G. Cuttone INFN Catania, Catania, Italy
F. Romano NPL, Teddington, UK
E. Simpson Australian National University, Canberra, Australia
D. Wright SLAC, Stanford, US
D. Sakata University of Wollongong, Wollongong, Australia
D. Konstantinov IHEP, Protvino, Russian Federation
D. Cutajar CMRP, University of Wollongong, Wollongong, Australia
D. Bolst CMRP, University of Wollongong, Wollongong, Australia
C. Omachi Nagoya Proton Therapy Center, Nagoya, Japan
C. Mancini-Terracciano Roma 1, INFN, Italy
C. Fedon Radboud University Medical Center, Nijmegen, The Netherlands
B. Faddegon University of California, San Francisco, US
A. Perales Medical Physics Department of Clí nica Universidad de Navarra, Spain
A. Mantero SWHARD srl, Genova, Italy
A. Dotti former SLAC, Stanford, US

Presentations

M. A. Cortes-Giraldo et al., "G4_Med, a Geant4 benchmarking tool for medical physics applications"; ENSAR2 workshop: Geant4 in nuclear physics; Madrid (Spain), April 24-26, 2019.

Collaboration web page

-- SusannaGuatelli - 2019-04-18


This topic: Geant4 > WebHome > G4MSBG
Topic revision: r38 - 2019-04-18 - MiguelAntonioCortesGiraldo
 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright &© 2008-2021 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
or Ideas, requests, problems regarding TWiki? use Discourse or Send feedback