Welcome to the Twiki web page of the G4MSBG initiative: G4-Med

Purpose

The aim of the Geant4 Medical Physics Benchmarking Group (G4MSBG) is to develop a fully automatised Geant4 benchmarking and regression testing system for medical physics applications, called G4-Med. A set of Geant4 Physics Constructors and Lists of interest for medical physics applications are tested. The tests are integrated in the geant-val test system to be executed for benchmarking and regression testing. The test are executed using the CERN computing infrastructure.

List of current tests

Currently the G4-Med system includes 18 tests.

Test geant-val layout AuthorsSorted ascending
Electron scattering from foils at 13-20 MeV kinetic energies ElecForwScat B. Faddegon, J. Ramos-Méndez
Bragg curves in water for 67.5 MeV protons LowEProtonBraggPeak B. Faddegon, J. Ramos-Méndez
Absolute neutron yield for protons ProtonC12NeutronYield B. Faddegon, J. Ramos-Méndez
Bremsstrahlung yield Bremsstrahlung B. Faddegon,J. Ramos-Méndez
Dosimetry for mammography Mammo C. Fedon, I. Sechopoulos
62 MeV /n C-12 fragmentation on Carbon target LowEC12Frag C. Mancini-Terracciano
Production cross sections of different fragments C12FragCC C. Omachi, T. Toshito, T. Sasaki
400 MeV/n C-12 fragmentation C12Frag D. Bolst, S. Guatelli, F. Romano
Hadronic nucleus-nucleus inelastic cross section NucNucInelXS D. Sakata, S. Guatelli, E. Simpson
Estimation of proton radiobiological damage Radiobiology G. Petringa, GAP Cirrone L. Pandola, G. Cuttone
Dosimetry - clinical 5-6 MeV electron beam To be added L. Desorgher
Light ion (proton, 3He, carbon) range and depth dose curves in water LightIonBraggPeak M. Cortes-Giraldo, A. Perales, J. M. Quesada Molina
Fano cavity Fano cavity P. Arce , M. Maire, M. Novak
Low energy electron backscattering ElectronBackScat P. Dondero, A. Mantero,V. Ivanchenko, M. Novak
Brachytherapy - dose rate Brachy-ir S. Guatelli, D. Cutajar
Photon attenuation coefficients PhotonAttenuation S. Guatelli, L. Pandola
Electron Dose Point Kernel LowEElecDPK S. Incerti, M.-C. Bordage, I. Kyriakou, Y. Perrot
Microdosimetry Microyz S. Incerti, I. Kyriakou
Electron stopping powers ElectronDEDX V. Ivanchenko

Development of the benchmarking/regression system and Integration of tests in geant-val

Collaborators

Coordinator: S. Guatelli (University of Wollongong, Wollongong, Australia), e-mail: susanna@uowNOSPAMPLEASE.edu.au

Deputy Coordinator: P. Arce (CIEMAT,Madrid, Spain), e-mail: pedro.arce@ciematNOSPAMPLEASE.es

Founder and Coordinator Oct, 2014-August, 2018: B. Faddegon (University of California San Francisco, USA), email: bruce.faddegon@ucsfNOSPAMPLEASE.edu

Mailing list: geant4-medical-bench@cernNOSPAMPLEASE.ch . alias: geant4-med@cernNOSPAMPLEASE.ch

Remember to remove the NOSPAMPLEASE.

Collaborators list

Collaborators Institute
Pedro Arce CIEMAT, Madrid, Spain
D. Bolst CMRP, University of Wollongong, Wollongong, Australia
M.-C. Bordage CRCT (INSERM and Paul Sabatier University), Toulouse, France
P. Cirrone INFN Laboratori Nazionali del Sud, Catania, Italy
M. Cortes-Giraldo Universidad de Sevilla, Sevilla, Spain
G. Cuttone INFN Laboratori Nazionali del Sud, Catania, Italy
D. Cutajar CMRP, University of Wollongong, Wollongong, Australia
L. Desorgher Radiophysics Institute, Lausanne, Switzerland
P. Dondero SWHARD srl, Genova, Italy
A. Dotti former SLAC, Stanford, US
B. Faddegon University of California, San Francisco, US
C. Fedon Radboud University Medical Center, Nijmegen, The Netherlands
S. Guatelli University of Wollongong, Wollongong, Australia
S. Incerti CENBG, Bordeaux, France
V. Ivanchenko Tomsk State University, Tomsk, Russian Federation
D. Konstantinov IHEP, Protvino, Russian Federation
I. Kyriakou Ioannina University, Ioannina, Greece
G. Latyshev IHEP, Protvino, Russian Federation
M. Maire LAPP, IN2P3, Annecy, France
C. Mancini-Terracciano Roma 1, INFN, Italy
A. Mantero SWHARD srl, Genova, Italy
M. Novak CERN, Geneva, Switzerland
C. Omachi Nagoya Proton Therapy Center, Nagoya, Japan
L. Pandola INFN Laboratori Nazionali del Sud, Catania, Italy
A. Perales Medical Physics Department of Clí nica Universidad de Navarra, Spain
Y. Perrot IRSN, France
G. Petringa INFN Laboratori Nazionali del Sud, Catania, Italy
J. M. Quesada Molina Universidad de Sevilla, Sevilla, Spain
J. Ramos-Méndez University of California, San Francisco, US
F. Romano NPL, Teddington, UK
D. Sakata University of Wollongong, Wollongong, Australia
L. Sarmiento Lund University, Lund, Sweden
T. Sasaki KEK, Tsukuba, Japan
I. Sechopoulos Radboud University Medical Center, Nijmegen, The Netherlands
E. Simpson Australian National University, Canberra, Australia
T. Toshito Nagoya Proton Therapy Center, Nagoya, Japan
D. Wright SLAC, Stanford, US

Presentations

  • M. A. Cortes-Giraldo et al., "G4_Med, a Geant4 benchmarking tool for medical physics applications"; ENSAR2 workshop: Geant4 in nuclear physics; Madrid (Spain), April 24-26, 2019.
  • S. Guatelli et al., "G4_Med, a Geant4 benchmarking tool for medical physics applications"; MCMA 2019, Montreal, Canada, June 19-21, 2019.

-- SusannaGuatelli - 2019-04-18


This topic: Geant4 > WebHome > G4MSBG
Topic revision: r46 - 2020-03-11 - SusannaGuatelli
 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright &© 2008-2023 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
or Ideas, requests, problems regarding TWiki? use Discourse or Send feedback