TWiki> Geant4 Web>G4MSBG>G4MSBGBrachy (revision 1)EditAttachPDF

Brachytherapy test

The test is based on the Geant4 advanced example Brachytherapy.

The test calculates the dose rate distribution g(r) of a Flexisource brachytherapy source. The results are compared to the reference data published in D. Granero, J. Pérez-Calatayud, E. Casal, et al, "A dosimetric study on the Ir-192 high dose rate Flexisource", Med. Phys. 33 (12), 2006, 4578-82.

The g(r) is calculated with Geant4 EMStandard_opt0, EMStandard_opt3, EMStandard_opt4, Livermore and Penelope physics lists.

-- SusannaGuatelli - 2018-11-23

Edit | Attach | Watch | Print version | History: r5 | r4 < r3 < r2 < r1 | Backlinks | Raw View | Raw edit | More topic actions...
Topic revision: r1 - 2018-11-23 - SusannaGuatelli
 