<!-- * Set TWIKISTYLEURL = %PUBURLPATH%/%BASEWEB%/%WEBPREFSTOPIC%/blogstyle.css * Set RELEASEEDITLOCKCHECKBOX = checked = "checked" --> %INCLUDE{"TabsAllDec"}% <div id="topicb" style="width:1000px"> <div class="topicbody"> <a href="https://twiki.cern.ch/twiki/bin/view/HCC/">Back to overview</a> ---++ YOU ARE VIEWING %TOPIC% %STARTINCLUDE% ---++++ <a href="%TOPIC%">Preparation for Cool Down sec78 - 5th Dec 06</a> %FILELIST{format="$fileIcon $fileName:$br $fileUrl $br $fileComment $br" topic="%TOPIC%"}% Open Issues: AC non-conformity * 21.11.06 Non-conformity on instrumentation cables (temperature sensors on current leads) (A.Suraci: 3 cables are in repair-Wed.29th) * 13.11.06 Non-conformity of the crates of cryo instrumentation (inrush current) (A.Suraci: ready next year) * 13.11.06 Non-conformity of the AC cabling of the crates under the magnets. This concerns ACR, MEL, orbit corrector power converters & VAC. DC cabling * 04.12.06 Access & Safety Cable Installation (full sector) (J-C.Guillaume; end by Dec 7th) * 30.11.06 Non conformity: 6 temperature sensor cables need repair (D.Bozzini, A.Suraci) * 25.11.06 Functional test on the leads heaters: DFBAO, DFBMA, DFBMC, DFBXG * 22.11.06 Pre-connection of 120A cables in LSSR7 (TS/EL) * 20.11.06 Galvanic insulation installation on all DFBs (AT/MEL) * 13.11.06 6 kA and 13 kA cables positioning at DFBAO, DFBMA, DFBMC, DFBAN (Flohe) Assembly - Vacuum - Cryogenics * 22.11.06 Cryo-valves remote control in CCC by AB/CO * 22.11.06 Control of quench valve * 17.11.06 Instrumentation cable HV tests in LSS8L (A.Suraci: 4 cables to be tested) DFB Commissioning * 04.12.06 Re-positioning collars used to fix the WRL to the CLs (all DFBs) (A.Perin-D.Bozzini-F.Millet) * 29.11.06 Pumping of insulation vacuum for DFBX Safety General remark: written communication in advance to announce operations!!! * 25.11.06 ElQA-TP4B safety procedure (1900 volts tests!). * 23.11.06 Wooden structure for UA access restriction (that will allow transport). * 23.11.06 Water leak on the tunnel concrete wall to be fixed (C33L8). * 16.11.06 Cool down safety procedure & access conditions Preparation of powering test * 22.11.06 Installation of flexible cables by CV (UA83) * 16.11.06 Water circulating in UA83 for the Powering Procedure Test: filters need to be checked. AOB * 13.11.06 BPM connection in Q2, Q3, Q4, Q5, Q6, Q7–wk49 (J-C.Guillaume & R.Jones) * 13.11.06 Quench protection continuity tests and cables assignment LLS7R (DFBMH, DFBAN) and LSS8L (DFBMC, DFBMA and DFBX) -- Main.MircoCoccoli - 05 Dec 2006 - 13:47 #CommentAnchor %STOPINCLUDE% %COMMENT{type="above" target="#CommentAnchor"}% </div> <div class="rightbar"> %INCLUDE{"RightBarDecAll"}% </div> </div> <script type="text/javascript"> //<pre> setTimeout("var j = document.getElementById('topicb').getElementsByTagName('img');for(i in j){if(j[i].width>600) j[i].setAttribute('width','600');}",100); //</pre> </script>
Attachments
Attachments
Topic attachments
I
Attachment
History
Action
Size
Date
Who
Comment
pdf
RAT_20061205_wslides.pdf
r1
manage
192.0 K
2006-12-05 - 13:49
MircoCoccoli
Minutes with Presentation by D.Bozzini attached
This topic: HCC
>
WebHome
>
BlogEntryPoint8x2006x12x05x13x47
Topic revision: r2 - 2006-12-08 - MircoCoccoli
Web page prepared by
Małgorzata Macuda & Jacek Szkutnik