Manual Squeezing test (PSQ). Test OK. (The test will be considered as fully passed only once automatic function is used)
When Squeezing was finished, the magnet was ramped to nominal current (3610 A) and kept there for "endurance test"; after one hour, the B2 converter tripped and a FPA was initiated: analysis of the PM signals was indicating an external interlock alarm - red emergency button pressed. Nobody was in the area at that moment.
The two converters were ramped back to nominal and kept there; after three hours, the same trip as before was experienced on B2 and the FPA initiated. The circuit was blocked for powering.
Further investigations showed that the two trips were provoked by a mispositioned pin in the connector on the emergency red button. Already fixed by PO.
RQ6.R7B1 and RQ6.R7B2
PCC completed by PO and QPS in the tunnel of point 7.
PIC2 CRYO-OK passed on RQ6.R7B1, RQ6.R7B2, RCBH6.R7B2 and RCBV6.R7B1.
Remaining steps of PIC2 passed on RCBH6.R7B2. Not possible to continue with the others due to a communication problem with QPS detectors; a manual reset in UA83 is needed.
Planning for Thursday 07/06/2007
RQ6.R7B1 and RQ6.R7B2
Complete PIC2 on the two 600 A circuits and the corrector RCBV6.R7B1