Back to overview
YOU ARE VIEWING BlogEntryPointx2007x06x11x15x54

RAT_20070611.pdf:
https://twiki.cern.ch/twiki/pub/HCC/BlogEntryPointx2007x06x11x15x54/RAT_20070611.pdf

_Direct_Quench_Detection_with_Shunt.ppt:
https://twiki.cern.ch/twiki/pub/HCC/BlogEntryPointx2007x06x11x15x54/_Direct_Quench_Detection_with_Shunt.ppt
Test Report of Monday 11/06/2007
- AB-PO performed "type test" on RPLA.12L8.RCBH12.L8B2
- Special test on RD2.L8: Quench Heater discharge at 200A (Reiner) - Signal cable to be fixed (Vincent)
- 600A PC de-consigne: RQT12.L8B1 RQTD.A78.B1 RQTD.A78.B2 RQTF.A78.B1 RQTF.A78.B2 RSD1.A78.B1 RSD1.A78.B2 RQS.L8.B1 RSD2.A78.B1 RSD2.A78.B2 RSF1.A78.B1 RSF1.A78.B2 RSF2.A78.B1 RCD.A78.B1 RCS.A78.B1 RCS.A78.B2
- AB-CO performed sequencer procedure of 600A circuits - not terminated, half day needed.
Planning for Tuesday 12/06/2007
- ElQA on 13kA circuits
- ElQA on 600A
- Implementation on RQ6.R7 and on L8 600A circutis of the second order monitoring software by AT-MEL - See attached presentation given by Bob Flora during the afternoon RAT in CCC
- QPS Software test on RQ6.R7
- Sequencer verification for 600A circuits - second part
- PCC on 600A when released by AT-MEL
- PCS on the first bunch of 600A circuits