TWiki home | Point 1 | Point 2 | Point 3 | Point 4 | Point 5 | Point 6 | Point 7 | Point 8 | Minutes |
Created by Main.MirkoPojer on 2007-05-03 - 23:46
Edit, attach file or add comment
Created by Main.MirkoPojer on 2007-05-03 - 22:55
Position | T [°C] | T_meteo [°C] | RH_meteo [%] | Condensation | Comments |
---|---|---|---|---|---|
DFBMC | 20.7 | 38.8 | |||
Q6_L8 (120A) | 9 | Yes | |||
Q8_L8 (60A) | 9.5 | No | |||
Q9_L8 (60A) | 13 | No | |||
Q10_L8 (60A) | 10 | Yes | |||
Q11_L8 (60A) | 9.5 | No | |||
Q12_L8 (60A) | 9 | 18.5 | 41.4 | Yes | |
Q13_L8 (60A) | 10 | No | |||
Q14_L8 (60A) | 9 | No | |||
Q15_L8 (60A) | 9 | Yes | |||
Q20_L8 (60A) | 9 | No | |||
Q25_L8 (60A) | 10 | No | |||
Q30_L8 (60A) | 10 | No | |||
Q30_R7 (60A) | 9.5 | Yes | |||
Q25_R7 (60A) | 10.5 | No | |||
Q20_R7 (60A) | 10 | No | |||
Q15_R7 (60A) | 9 | Yes | |||
Q14_R7 (60A) | 9 | Yes | |||
Q13_R7 (60A) | 9.5 | Yes | |||
Q12_R7 (60A) | 9.5 | 17.3 | 49 | Yes | |
Q11_R7 (60A) | 9 | Yes | |||
Q10_R7 (60A) | 9 | Yes | |||
Q9_R7 (60A) | 9.5 | Yes | |||
Q8_R7 (60A) | 9 | Yes | |||
Q7_R7 (60A) | 7 | Yes | |||
DFBAN | 18 | 45.9 |
Edit, attach file or add comment
Created by Main.MariaPazCasasLino on 2007-05-03 - 18:03
DFBMC | RCBCH5.L8B1 RCBCV5.L8B2 |
Connection of the DC cables to the power converters for these circuits (before 9:00) | AB/PO |
Verification of the connections at the DFBMC side | AT/MEL | ||
DFBAO | RQ6.L8B1 RQ6.L8B2 |
Switch on the flashing lights around the chimneys of RQ6.L8 circuit in the DFBAO | HCC |
Unlock and switch on the RPHGB.UA83.RQ6.L8B1 and RPHGB.UA83.RQ6.L8B2 converters. | AB/PO |
||
Sequencer tests on powering procedures for 6kA magnets with 2 PCs ("Q4Q5" procedure) | AB/CO |
DFBMC | RCBCH5.L8B1 RCBCV5.L8B2 |
Balisage with flashing lights | HCC |
PC Configuration (test of PC and magnet at minimum current) | AB/PO | ||
RQ5.L8 | Unlock of the quench heater power supplies (DQHDS) of Q5 and charge. | AT/MEL | |
PC Configuration | AB/PO | ||
RCBCH5.L8B1 RCBCV5.L8B2 RQ5.L8 |
PIC2 | HCC AB/CO AB/PO AT/MEL AT/ACR |
|
P2N | HCC AB/CO AB/PO AT/MEL AT/ACR |
DFBMC | RCBCH5.L8B1 RCBCV5.L8B2 |
Connection of the DC cables to the DFBMC leads of the two 120A circuits which passed the ElQA tests | AT/MEL |
DFBAO | RQ6.L8B1 RQ6.L8B2 |
Balisage around the chimneys | HCC |
Unlock and switch on the RPHGB.UA83.RQ6.L8B1 and RPHGB.UA83.RQ6.L8B2 converters. Check of the short-circuit and the insulation. | AB/PO |
||
Sequencer tests on powering procedures for 6kA magnets with two power converters ("Q4Q5" procedure) | AB/CO |
||
Lock and switch off the RPHGB.UA83.RQ6.L8B1 and RPHGB.UA83.RQ6.L8B2 converters | AB/PO |
|
Unlock and switch on the RPLB.UA83.RCBCVS5.L8B1 converter for sequencer Tests 80-120 A | AB/PO | |
|
Sequencer tests 80-120A AB/CO | AB/CO |
DFBAO | Installation of dry-air bags on the DFBMA chimneys | AT/ACR |
DFBMC | Installation of two heaters in two 120 A chimneys and of the air blowers for the 6kA leads | AT/ACR |
Edit, attach file or add comment
Created by Main.MariaPazCasasLino on 2007-05-03 - 13:41
Edit, attach file or add comment
Created by Main.MikeKoratzinos on 2007-05-03 - 12:59
Edit, attach file or add comment
Created by Main.MariaPazCasasLino on 2007-05-03 - 12:52
Edit, attach file or add comment
Created by Main.MirkoPojer on 2007-05-03 - 02:01
Position | T [°C] | T_meteo [°C] | RH_meteo [%] | Condensation | Comments |
---|---|---|---|---|---|
DFBMA | |||||
120A-4 | 14 | No | Setpoint 40K - additional heaters | ||
120A-8 | 13 | No | Setpoint 50K - additional heaters | ||
6kA | 8 (on top of G11) | Yes | No condensation on chimneys - Setpoint 50K | ||
DFBMC | 20.5 | 44.2 | |||
6kA | 8 (on G11) | No | Setpoint 70K | ||
120A-8 | 11 | No | Setpoint 50K - additional heaters not working | ||
120A-4 | 11 | No | Setpoint 40K - additional heaters not working | ||
DFBAO_LCM | |||||
Q6_L8 (120A) | 8 | Yes | |||
DFBAO_HCM | |||||
Q9_L8 (60A) | 12 | No | |||
Q10_L8 (60A) | 11 | No | |||
Q11_L8 (60A) | 10 | No | |||
Q12_L8 (60A) | 9 | 18.3 | 49.5 | Yes | |
Q13_L8 (60A) | 11 | No | |||
Q14_L8 (60A) | 9 | Yes | |||
Q15_L8 (60A) | 10 | Yes | |||
Q20_L8 (60A) | 9 | Yes | |||
Q25_L8 (60A) | 11 | Yes | |||
Q30_L8 (60A) | 11 | Yes | |||
Q30_R7 (60A) | 10 | - | |||
Q25_R7 (60A) | 11 | - | |||
Q20_R7 (60A) | 10 | No | |||
Q15_R7 (60A) | 9 | Yes | |||
Q14_R7 (60A) | 9 | Yes | |||
Q13_R7 (60A) | 15? | No | |||
Q12_R7 (60A) | 10 | 17.3 | 53.4 | Yes | |
Q11_R7 (60A) | 9 | Yes | |||
Q10_R7 (60A) | 9 | Yes | |||
Q9_R7 (60A) | 10 | No | |||
Q8_R7 (60A) | 9 | Yes | |||
Q7_R7 (60A) | 9 | Yes | |||
DFBAN | 18 | 49.9 | Yes | ||
600A | 10 | Yes | Setpoint 150K | ||
13kA | 10 | Yes | Setpoint 110K | ||
DFBMH | No | ||||
600A | 11 | No | Setpoint 120K |