Created by Main.BorisBellesia on 2007-06-13 - 20:48

quench_d2_q4.bmp:
https://twiki.cern.ch/twiki/pub/HCC/BlogEntryPoint8x2007x06x13x20x32/quench_d2_q4.bmp

D2-Q4.bmp:
https://twiki.cern.ch/twiki/pub/HCC/BlogEntryPoint8x2007x06x13x20x32/D2-Q4.bmp
Comments:
Edit, attach file or add comment
Created by Main.BorisBellesia on 2007-06-13 - 15:55
Report of Wednesday 13.06.2007
- ElQA
- Tests in MBA during all the day.
- RQ5.L8:
- Calibration test performed by AB/PO. Test ongoing.
- RD2.L8:
- Ramped to 200A. Quench heater fired. Post-mortem data acquired properly. Test OK
- Ramped to 1kA. Quench heater fired. Post-mortem data acquired properly. Test OK
- RQF and RQD
- RD2.L8
- Test 1 on the ML8 performed. D2 quenched when R4.L8B1 was at 2.2kA and R4.L8B2 was around 3kA ramping to 3.61kA. Test NOT OK.
Planning for Thursday 14.06.2007
AM:
- ElQA on MB with instrumentation + QF & QD
- RQ6.R7B1 and RQ6.R7B2: Repeat test
- QPS IST RQF.A78 and RQD.A78: discharge of the heaters
- RD2.L8 to nominal
- RQ5.L8 and their correctors calibration by PO (UA)
PM:
- 600 A circuits of L8: PCC (<20A) for all
- 600 A circuits of L8: PIC2 for all
- 600 A circuits of L8:PCS.1 for all
- List of the 600A circuits released by AT/MEL and AT/ACR
- RQTL12.L8B1
- RQTF.A78B1
- RQTF.A78B2
- RSD1.A78B2
- RQS.L8B1
- RSD2.A78B1
- RSF1.A78B1
- RSF1.A78B2
- RCO.A78B1
- AB/PO Type tests on 60A converter
Edit, attach file or add comment