Parameters required for tests:
Luis will provide a list of charge numbers and spot sizes.
Useful Optics Info
Typical Quad Settings: Luis,
The following parameters are the quadrupole setting at 2007/11/01.
The parameters are calculated with SAD code.
L is the effective length of magnet,
and K1 is the integrated k-value K1=L*k1.
If you don't have MAD deck of ATF extraction line,
please contact to
MarK Woodley in SLAC (
mdw@slacNOSPAMPLEASE.stanford.edu ).
He has the MAD deck of ATF extraction line.
Thank you.
Toshiyuki Okugi, KEK
QUAD QM6R =(L =.198745 K1 =-.71174 )
QM7R =(L =.078907 K1 =.40822 )
QK0X =(L =.075 K1 =0 ROTATE =45 DEG )
QD1X =(L =.07867 K1 =-.050004 )
QD2X =(L =.07867 K1 =-.45584 )
QF1X =(L =.07867 K1 =.42198 )
QS1X =(L =.1 K1 =0 ROTATE =45 DEG )
QF2X =(L =.078765 K1 =.17252 )
QD3X =(L =.19861 K1 =-.3609 )
QF3X =(L =.19861 K1 =1.3325 )
QF4X =(L =.19861 K1 =1.3053 )
QS2X =(L =.1 K1 =0 ROTATE =45 DEG )
QD4X =(L =.19861 K1 =-.69982 )
QD5X =(L =.19861 K1 =-.3064 )
QF5X =(L =.19861 K1 =.14723 )
QK1X =(L =.07867 K1 =0 ROTATE =45 DEG )
QD6X =(L =.078907 K1 =.19307 )
QK2X =(L =.07867 K1 =0 ROTATE =45 DEG )
QD7X =(L =.19861 K1 =0 )
QK3X =(L =.07867 K1 =0 ROTATE =45 DEG )
QF6X =(L =.19861 K1 =0 )
QK4X =(L =.07867 K1 =0 ROTATE =45 DEG )
QD8X =(L =.198745 K1 =0 )
QF7X =(L =.198745 K1 =0 )
QD9X =(L =.198745 K1 =0 )
________________________________
MAD decks are attached.
For more info, look at:
http://pcfj.hep.phy.cam.ac.uk:8080/ATF+Damage+Studies/3
--
NigelWatson - 07 Jan 2008
Topic revision: r2 - 2008-01-14
- unknown