TWiki> LHCb Web>LHCbHerschel>CaloFESetup>CaloFETest (revision 3)EditAttachPDF

Commissionning of the Herschel FE Crate

Timing scan

Dan please document

ADC conversion factor measurement

To redo

Triggering the L0 sequence from external input and reading RAM

TO rewrite....

The L0 sequence generated by the CROC can be triggered from an external source by sending a -800mv pulse on the "Trig L0 Seq" input of the CROC front plane. This can replace the manual triggering of the L0 Sequence which is done by pressing the "Trigger L0 Seq" button of the CROC panel.

Setup description

The external signal is generated from a waveform generator. In order to have the crate and generator sharing the same clock, the waveform generator recieve a 20MHz clock from the CROC through the "clock div" output of the CROC front plane. By default the divided clock has a 1Hz frequency. This can be set to 20MHz in the CROC CAT panel by setting Clock-->Div to 2 instead of 40000000 and pressing Apply.

The generator provide a single pulse of 25ns width, with a -800mV amplitude. This output is directed to "Trig L0 Seq" input of the CROC front plane.

Configuration

Setup the CROC (clock origin and RAM spying configuration), and fill the FE RAM (for detailled procedure, see "Hands-on CAT and the boards"). Prepare the required L0 Sequence. The "L0 Delay" can be used to delay the start of the L0 sequence from the N clock count after the board receive the signal that trigger the L0 sequence.

On the FE panel:

  • Press the ChannelB-->Calibration button (this tells the FE to be ready to send the RAM?)
On the CROC panel:
  • Press the General Control--> Enable Seq button. This tells the spyRAM to get ready to receive a L0 sequence. (validL0seq function of croc spyPGA)
  • Launch the triggerring of the L0Sequence from the generator.
  • Press the Spy-->Transfer-->Start and then Spy-->Transfer-->View

In this configuration the result is not different from what one would get from just pressing the "Acquisition" button but the internal logic is different: Acquision correspond to pressing "Enable Seq","Trigger L0", "Start" and "View", where "Trigger L0" launch the L0 sequence. Here we replace "Trigger L0" by the pulse from the generator.

Sending data from a waveform generator and spying them in the CROC SpyPGA

trigger the generator with the Seq L0 output of the CROC front plane or trigger the Seq L0 from the generator by sending a pulse to the Trig seq L0 input of the CROC front plane. Advantage of the first solution is that it can be run automatically since trigger L0 seq button (and the function behind) will trigger both the seq and the generator while the first one needs a manual trigger of the generator

Synchronisation of the channels in DAQ

Victor please document

Synchronisation of the channels in Trigger

TODO

-- VictorCoco - 03 Oct 2014

Edit | Attach | Watch | Print version | History: r4 < r3 < r2 < r1 | Backlinks | Raw View | Raw edit | More topic actions...
Topic revision: r3 - 2014-10-03 - VictorCoco
 