ECS PCs in D2 (vlan 102)

Sub-nets:

  • 10.130.20.254 / 24
  • 10.131.20.254 / 24

Ports:

  • Gi 4/0-11
  • Gi 1/6 - 14
  • Gi 5/0 - 47

Ports used:

Port host(s) Comment
Gi 4/0 INFDAI01W New Rackctrl pc
Gi 4/1 OTDCSRAS02W OT Rasnik 02
Gi 4/2 MUHVA02W Muon HV side A
Gi 4/3 MUHVC02W Muon HV side C
Gi 1/6 MUDAQA03W M4-5 Side A
Gi 1/7 MUDAQA04W Muon ODE Side A
Gi 1/8 MUDAQA02W M2-3 Side A
Gi 1/9 MUDAQA01W M1 Side A
Gi 1/10 MUHVA01 Muon high voltage Side A - PC in D3
Gi 1/11 VEDAQC01 Velo SPECS server Side C
Gi 1/12 MULVA01W Muon low voltage Side A
Gi 5/0 OTDAQA01 SPECS control
Gi 5/1 ITRCM01 IT RCM VME server
Gi 5/2 OTDCSLV01W CAEN & Marathon control
Gi 5/3 OTHV01W CAEN & Marathon control
Gi 5/4 ECDAQHVC01W SPECS control
Gi 5/5 PSDAQHVC01W SPECS control
Gi 5/6 MUDCS01W MUON Temperature control
Gi 5/7 RIDCS03 RICH Camera
Gi 5/8 ITHVDCS01W CAEN & Marathon control
Gi 5/9 TTHVDCS01W CAEN & Marathon control
Gi 5/10 ITDAQA02 SPECS control
Gi 5/11 TTDAQA02 SPECS control
Gi 5/12 MULVC01W Muon low voltage Side C
Gi 5/13 HCDCS01W CALO Rad. monitoring
Gi 5/14 INFDAIA01W Controls PC for Rack monitoring (CAN)
Gi 5/15 HCDAQHVC01W CALO SPECS C side
Gi 5/16 OtFanout this port connects a fan-out switch
Gi 5/17 VEDCS01W Controls PC for VELO VACM
Gi 5/18 R2DAQ02W SPECS control
Gi 5/19 R2DCS01W CAEN & Marathon control
Gi 5/20 R2DCS02W ELMB control
Gi 5/21 OTDCS01W Eth control
Gi 5/22 R2DAQ01W SPECS control
Gi 5/23 VEDAQA01W SPECS control
Gi 5/24 R1DAQ02W SPECS control
Gi 5/25 ECHVA01W SPECS control
Gi 5/26 ECHVC01W SPECS control
Gi 5/27   Free - ECS02W moved to SX
Gi 5/28 ECDAQHVA01W ECAL SPECS
Gi 5/29 HCDAQHVA01W ECAL SPECS
Gi 5/30 PSDAQHVA01W ECAL SPECS
Gi 5/31 MUDAQC02W M2-3 Side C
Gi 5/32 MUDAQC03W M4-5 Side C
Gi 5/33 MUDAQC04W Muon ODE Side C
Gi 5/34 MUDAQC01W M1 Side C
Gi 5/35 MUHVC01 Muon HV Side C - PC in D3
Gi 5/36 TPUDCS01W L0 PileUp Maraton
Gi 5/37 MUHVDCSC02W Muon high voltage Side C
Gi 5/38 INFMAG01W Magnetmonitoring
Gi 5/39 MUODEC01W MUON ODE Side C
Gi 5/40 MUODEA01W MUON ODE Side A
Gi 5/43 VEDCS02W PLC (Vac + Mot) control
Gi 5/44 CADCS01W Eth control
Gi 5/45 OTDAQC01 SPECS control
Gi 5/46 CADCS02W CALO ELMBs
Gi 5/47 R1DSC02W RICH 1

-- GaryMoine - 29 Jan 2008 - Add free Ports after ECS pc moved to SX
-- GaryMoine - 12 Mar 2008 - New Specs PC for EC HV split plugged to Gi 5/25


This topic: LHCb > WebHome > LHCbOnline > NetworkManagement > PortsUX01 > CtrlUX
Topic revision: r55 - 2008-03-26 - GaryMoine
 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright & 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.