Overview

The high voltage and bias for the PMTs are supplied by CAEN modules located in D3 (rack D3B05). The power supply system comprises
  • an SY5527 main frame,
  • an A1535 module (24 channels, 3.5 kV, 3 mA), located in slot 0,
  • two A1538D modules (12 channels, 1.5 kV, 10 mA), located in slots 3 and 5.

The A1535 provides the HV for all PMTs, the A1538D in slot 3 provides the bias for the B side stations, and the A1538D in slot 5 provides the bias for the F side stations.

Board Module Function Channels Station
0 A1535 HV 00 - 03 B0
      04 - 07 B1
      08 - 11 B2
      12, 13 not connected
      14 - 17 F1
      18 - 21 F2
      22, 23 not connected
3 A1538D Bias 00 - 03 B0
      04 - 07 B1
      08 - 11 B2
5 A1538D Bias 00 - 03 F1
      04 - 07 F2
      08 - 11 not connected

The HV settings for RUN2 are given in the document below. The Bias should be -333V on all channels.

Control

The SY5527 main frame is registered on the network as hrccaen01. It is interfaced to the ECS through OPC. The OPC clients are running on hrccc0104w.

In normal operation, the HV is controlled through the FSM. When switching on make sure to first ramp up the bias voltages (nodes HRC_HV_BIASB and HRC_HV_BIASF) and only after they have reached the nominal value (-333 V) the HV (nodes HRC_HV_HVB and HRC_HV_HVF). An overview of the voltages, currents and states of each channel is displayed on the panel associated to the HRC_HV node.

The recipes (i. e. settings for voltage, trip current, ramp speed, and voltage limit associated to the READY and STANDBY states) for HV and bias can be inspected and modified by navigating to the respective subnode (HRC_HV_HVB/F, HRC_HV_BIASB/F) and clicking on the button "Recipes…". On the panel which pops up, click "Load from file…" to import the settings from a text file, check that the table is updated correctly, and click "Save".

In addition to the normal control through WinCC, the status can be checked through simple tools provided by CAEN.

  • To see the status of the SY5527, open hrccaen01 in a web browser.
  • To see the status of the channels, go to /group/hrc/hv/ and do java -jar ChannelsController.jar hrccaen01 uname pwd (replace uname and pwd by the login and password).

Other information

The MAC address of the SY5527 main frame is 00-30-64-22-61-3F.

The main frame and the A1535 module are registered in the CERN electronics pool database.

LHC Inv/Serial Manufacturer Part No Serial No Type
7424 0001 CAEN SY55CR 106 Mainframe
7425 0005 CAEN A4528B 242 Module
7428 0016 CAEN A4531 213 Power-Supply
7420 0005 CAEN A1535SN 716 Module

The A1538D modules are not covered by the CERN/CAEN frame contract.

Topic attachments
I Attachment History Action Size Date Who Comment
PowerPointppt 20150902-LED-far-near.ppt r1 manage 181.5 K 2015-10-09 - 17:41 RustemDzhelyadin Measurement of far-near LED ratio on 2015-09-02 after irradiation during Summer
PDFpdf Attenuation-vs-Length-CK50.pdf r1 manage 57.9 K 2015-08-07 - 13:02 RustemDzhelyadin The attenuation vs cable length for CK50 (thick cable). Measured for spare cables.
PDFpdf B0-counters.pdf r1 manage 51.9 K 2015-07-01 - 16:48 RustemDzhelyadin B0 counters: the mip signal (pC) vs HV (kV)
PDFpdf B1-counters.pdf r1 manage 75.2 K 2015-07-01 - 16:50 RustemDzhelyadin B1 counters: the mip signal (pC) vs HV (kV)
PDFpdf B2-counters.pdf r1 manage 51.0 K 2015-07-01 - 16:51 RustemDzhelyadin B2 counters: the mip signal (pC) vs HV (kV)
PDFpdf F1-counters.pdf r1 manage 51.8 K 2015-07-01 - 16:55 RustemDzhelyadin F1 counters: the mip signal (pC) vs HV (kV)
PDFpdf F2-counters.pdf r1 manage 47.9 K 2015-07-01 - 16:57 RustemDzhelyadin F2 counters: the mip signal (pC) vs HV (kV)
PDFpdf FSC-all-m1.pdf r1 manage 112.5 K 2015-03-03 - 13:36 RustemDzhelyadin The HV settings for RUN2. The Bias should be -333V on all channels.
PDFpdf LEDcalibration0point.pdf r1 manage 18.5 K 2015-06-23 - 14:10 RustemDzhelyadin Starting point of LED (far/near) calibration assuming some rad-damages in the future
PDFpdf table-counters.pdf r1 manage 37.8 K 2015-07-01 - 19:06 RustemDzhelyadin Table (all counters) "mip' (pC) vs HV (kV)
Edit | Attach | Watch | Print version | History: r10 < r9 < r8 < r7 < r6 | Backlinks | Raw View | WYSIWYG | More topic actions
Topic revision: r10 - 2015-10-09 - RustemDzhelyadin
 
    • Cern Search Icon Cern Search
    • TWiki Search Icon TWiki Search
    • Google Search Icon Google Search

    LHCb All webs login

This site is powered by the TWiki collaboration platform Powered by PerlCopyright &© 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback