JeanPierreCachemiche - 9 Oct 2007
Reminder: on the control room PC the TFC panels are accessible at G:\online\ecs\Shortcuts\TFC\TFC_UI_DEN as shortcuy
Procedure
First switch off the ODIN board.
Then switch it on. Then:
- Launch a console on marmuon4
- Type ssh -X tfc@marmuon4
- For password ask Richard or Pierre-Yves.
- Type _ssh OdinV204 _ to connect on ODIN's CCPC
- Type top and wait the end of process jbi_pci which programs the board.
- Check that the process TFC_server is running, else restart from beginning
- Type q to exit the top program
- Type exit to log out from OdinV204.
Launch the PVSS interface by typing:
startPA 3.6

Click on
TFC30 and then on the green light icon.
Thre windows open:
- the log viewer window
- the PVSS console
- the FSMOperate panel
In the FSMOperate panel expand the tfc_10 node, then the TFC node
Right click on TFC_PART04 and select
View : the Top panel opens.
Check the number of Orbits is refreshed periodically and the TFC server caption in the upper right of the panel is blue with value OK. If not restart from the very beginning

Under
State click on the locker button and click on
Take : the greyed
not ready field turns to yellow.
Click on
not ready and choose
get ready : the field becomes blue and displays
READY
Configuration to get 16 consecutive L0_ACCEPT
Under the
Sub-system field double click on
tfcodin04: a panel opens
Click on the
Triggers 2 tab.
Tune the parameters in the Periodic trigger A field:
- Periodic trigger A period : 1
- Periodic trigger A offset : 0
- Per. trig. A burst length : 16
Then click on
Apply display and
close to close the window.
To send periodic triggers
Tick the
periodic trigger A case in the L0 trigger field on the right.
Click on the
READY button and select
START RUN : a window opens.
Click
SEND : the window closes.
Then the TFC is running with periodic triggers.
To stop the periodic triggers
Click on the
RUNNING button and select
STOP RUN.
Untick the
periodic trigger A case
Click on the
NOT_READY button and select
GET READY : the green light nearly in front of -Periodic trigger A_ switches off.
To send single shot triggers
Click on the
READY button and select
START RUN : a window opens.
Click
SEND : the window closes.
TFC is running without triggers.
Click on the
Single shots button : a window opens.
You can send single shot triggers by clicking on the
Shoot buton in front of
trigger A