Calorimeter Electronics Status
Below are compiled useful information addressing the current status of the calorimeter Electronics during the installation and the commissioning phase toward the final setup.
The expected final readout setup is described
here
and is summarized in the dedicated
LHCbCaloReadout wiki page.
ECAL/HCAL
FEB
- Side C Information on FEB, as of 0ctober 26th, is found in CROC test below
CROC
|
Date |
Resolved on |
|
ECAL_8 |
impossible to have any ECS communication with the FEBs. No test performed with this CROC. Problem had been already seen with 2 different CROC v2 (backplane, SPECS bus problem, A board affecting the SPECS bus, reset bus ???) In Orsay we found that the glue was not programmed correctly (checksum FFFF) the glue output was causing the Specs bus slave to master to be reserved by this board in slot 7 at all time preventing other boards to talk. Board now OK ready to be sent back to CERN |
22 Oct 2007 |
26 Oct 2007 |
|
ECAL_10 |
Data are dubious for several FEBs in synchronisation test. Noise tests are fine with usual time settings. CROC_28 has been replaced by CROC_24 in this crate. Still the synchronisation is dubious although the Noise test is fine. We observe that the board in slot 18 has a different Synchronisation plot from the others : the plot is shifted downward of at least 4ns. We never observed that at LAL or on the other crates. CROC_24 left in this crate ECAL 10 slot 18 board 050 showed this 4ns shift it was taken to Orsay and tested => no problem seen. T (JL) suspect a bus problem to be checked at CERN |
22 Oct 2007 |
26 Oct 2007 |
|
ECAL_11 |
board in slot 2 does not work properly. Board/Slot problem ??? This had been seen with CROC v2. Test of the CROC v4 was done by masking this board -> OK The +5V fuse is burnt, the board 096 is in office 002 building 1 waiting for the fuse to be replaced |
22 Oct 2007 |
26 Oct 2007 |
|
ECAL_14 |
board in slot 18 (FEB number 217) provides wrong data in pattern mode (e.g. synchronisation test). Pedestal is fine and acquisition is correct in this mode. Synchronisation requires ram pattern. Even configuring the board 'by hand', I could not have correct ram patterns at the level of the CROC or looking at the spy ram of the sequencer. Notice that event headers are ok but data look corrupted. Same test done with FEB in slot 17 is ok The CROC and board were retested on Oct 17th no problem were found??? the FEboard was left in slot 18 |
22 Oct 2007 |
26 Oct 2007 |
|
Date |
Resolved on |
|
ECAL_15 ... _25 |
To be installed |
22 Oct 2007 |
|
Backplanes
Power Supply
Spares
FEB
CROC
Backplanes
Power Supply
Cabling
Due to backplane problem the following FEB are currently moved with respect to their expected location.
Ecal crate #16 : FEB#12 and FEB#13 moved FROM slot 17 and 18 TO slot 18 and 19
Ecal crate #15 : FEB#13 moved FROM slot 18 TO slot 19
WARNING this slot is to be used by one LEDTSB
Hcal crate #22 : FEB#14 moved FROM slot 19 TO slot 20
NO problem as it's a PIN readout FEB
Comment : backplane from Ecal crate#15 and #16 need to be repared. Moving FEB affects
L0Calo.
PRS/SPD
FEB
CROC
|
Date |
Resolved on |
|
PRS_0 ... 3 |
To be installed |
22 Oct 2007 |
|
|
Date |
Resolved on |
|
PRS_4 ... 7 |
To be installed |
22 Oct 2007 |
|
Backplanes
Power Supply
Spares
FEB
CROC
Backplanes
Power Supply
Cabling
TELL1
Tell1 boards and crates
Trigger
Trigger Validation Boards
* Scan of TVB inputs:
Board |
Scan of HCAL Inputs |
Scan of ECAL Inputs |
0 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 8 slot 0-7 |
HCAL1 PatternA, HCAL1 PatternB |
HCAL2 PatternA, HCAL2 PatternB |
HCAL3 PatternA, HCAL3 PatternB |
1 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 8 slot 11-18 |
HCAL1 PatternA, HCAL1 PatternB |
HCAL2 PatternA, HCAL2 PatternB |
2 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 9 slot 0-7 |
HCAL1 PatternA, HCAL1 PatternB |
HCAL2 PatternA, HCAL2 PatternB |
HCAL3 PatternA, HCAL3 PatternB |
3 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 9 slot 11-18 |
HCAL1 PatternA, HCAL1 PatternB |
HCAL2 PatternA, HCAL2 PatternB |
4 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 10 slot 0-7 |
HCAL1 PatternA, HCAL1 PatternB |
HCAL2 PatternA, HCAL2 PatternB |
HCAL3 PatternA, HCAL3 PatternB |
5 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 10 slot 11-18 |
HCAL1 PatternA, HCAL1 PatternB |
HCAL2 PatternA, HCAL2 PatternB |
HCAL3 PatternA, HCAL3 PatternB |
6 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 11 slot 0-7 |
HCAL1 PatternA, HCAL1 PatternB |
HCAL2 PatternA, HCAL2 PatternB |
7 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 11 slot 11-18 |
HCAL1 PatternA, HCAL1 PatternB |
HCAL2 PatternA, HCAL2 PatternB |
8 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 12 slot 0-7 |
HCAL1 PatternA, HCAL1 PatternB |
HCAL2 PatternA, HCAL2 PatternB |
9 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 12 slot 11-18 |
HCAL1 PatternA, HCAL1 PatternB |
HCAL3 PatternA, HCAL3 PatternB |
10 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 13 slot 0-7 |
11 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 13 slot 11-18 |
HCAL1 PatternA, HCAL1 PatternB |
12 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 14 slot 0-7 |
HCAL1 PatternA, HCAL1 PatternB |
13 |
HCAL0 PatternA, HCAL0 PatternB |
Crate 14 slot 11-18 |
-- FredericMachefert - 22 Oct 2007