---+!! Operating the VELO Motion System while being under vacuum Make sure the PVSS-project "VEDCS_VacMot" is running under "velo_user" on "vedcs02w". If not, start it and also start via "Vision" the panel G:\velo\pvss\VELO_VacuumMotion\panels\VeloMotion_UI_Main.pnl <br /> <img src="%ATTACHURLPATH%/pvss.motionscreen.jpg" alt="pvss.motionscreen.jpg" width='958' height='820' /> A number of conditions has to be satisfied in order to be able to move the VELO-detectors. * the 2 red emergency mushroom buttons of the stepping motors in rack !C3B03 on platform C3 have to be pulled to the out-position, * all 3 coordinates of the system have to be in "referenced"-mode, as specified in the panel, * the motion-PLC has NOT to be in "local" but in "physics" mode, * The actual readings and a lot more can be seen at the Motion pages on the PLC-screen in rack !C3B05 on platform C3. However, access to these pages is password protected. -- Main.EddyJans - 31 Jul 2008
Attachments
Attachments
Topic attachments
I
Attachment
History
Action
Size
Date
Who
Comment
jpg
pvss.motionscreen.jpg
r1
manage
102.6 K
2008-07-31 - 15:23
EddyJans
This topic: LHCb
>
WebHome
>
LHCbVELO
>
VELOOperatingManuals
>
Motion
Topic revision: r1 - 2008-07-31 - EddyJans
Copyright &© 2008-2021 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.