TestBeamOct2019 @ DESY




This section will summarize the main documents, informations and results of the October/November 2019 testbeam.
A fiber based telescope was installed in the testbeam area TB22.

  • The layout is presented below.

Data access

The data can be found on:

Different set-up configurations (w/o lead plates)

setup1.pngsetup2.pngsetup3.png

Pictures of the setup

Pictures can be found in the following links:

<a href="https://photos.app.goo.gl/PBUiB3jqTE2swbnMA" rel="noopener noreferrer" target="_blank">https://photos.app.goo.gl/PBUiB3jqTE2swbnMA</a>

https://photos.app.goo.gl/1K4y31QS7CQWNJ5n7

Moving table info

moving_table.png

Detector coordinate system

detector_cs.png
Fixed beam and detector moving!

Run plan

  1. Over voltage scans 1: Runs with 500k and 50k trigers (OV=2,2.5,...,6V) @center
  2. Over voltage scans 2: Runs with 50k trigers (OV=2,2.5,...,6V) @positions 1-2-3-4 (see drawing)
  3. X and Y scans: 50 k triggers
  4. Lead runs 1: Placement of 1,2,3,4 lead plates in front of the entrance window
  5. X and Y scans (after new calibration)
  6. Over voltage scans 3: 1M triggers!
  7. Lead runs 2: Placement of 1,2,3,4,5,6 lead plates btw X2 and Y3
1. Over votage scans 1
Run # OV(V) I@SiPM Board01 (A) Number of triggers (10^3) T SiPM (C) T1 Board (C) T2 Board (C) Comments
1010 3.5   500 17-18 43.8 35  
1011 3.5   50 18-19 41 31.8  
1020 4.0   500 17-18 43.7 34.6  
1021 4.0   50 16-17 40.6 30.9  
1030 4.5   500 17-18 42.5 33.8  
1031 4.5   50 17-18 43.0 32.4  
1040 5.0   500 18-19 43.6 34.1  
1041 5.0   50 17-18 41.6 31.9  
1050 5.5 17.6 500 17-18 42.5 31.6  
1051 5.5 17.6 50 16-17 40.8 31.6  
1060 6.0 21.7 500 18-19 43.4 34.5  
1061 6.0 21.7 50 17-18 42.0 32.4 Calibration run with a board not properly configured, use previous calibration run
1070 6.5 21.7 500 16-17 40.7 30.9  
1071 6.5 21.7 50 16-17 40.3 31.5  
1080 2.0 3.6 500 17-18      
1081 2.0 3.6 50 16-17      
1090 2.5 4.6 500 16-17      
1091 2.5 4.6 50 17-18      
1100 3.0 6.0 500 17-18      
1101 3.0 6.0 50 17-18      
Changed one of the temperature to SiPM Al support

2. Over votage scans 2

Run # OV (V) N triggers (10^3) Position X(mm) Y(mm) T SiPM (C) T1 Board (C) T2 SiPM (C) Comments
1200 3.5 50 1 -30 +30 19.5 31.4-35.0 18.6-20.3  
1201 3.5 50 2 -30 -30   35 20  
1202 3.5 50 3 +30 -30   32 20 lost some events < 0.1%
1203 3.5 50 4 +30 +30   32 19.1  
1204 3.5 50 1 -30 +30   32 19.1 remeasured by mistake
1205 4.0 50 2 -30 -30   33 20  
1206 4.0 50 1 +30 -30   32 19.1  
1207 4.0 50 3 +30 -30   32 20  
1208 4.0 50 4 +30 +30   32 19.1  
1209 4.5 50 1 -30 +30   32 19.1  
1210 4.5 50 2 -30 -30   35 20  
1211 4.5 50 3 +30 -30        
1212 4.5 50 4 +30 +30        
1213 5.0 50 1 -30 +30        
1214 5.0 50 2 -30 -30        
1215 5.0 50 3 +30 -30        
1216 5.0 50 4 +30 +30       Calibration run not properly configured @ boards 2 and 7
1217 5.5 50 1 -30 +30 19.5 31.5-35.1 18.3-19.4  
1218 5.5 50 2 -30 -30       Calibration run not properly configured @ board 3
1219 5.5 50 3 +30 -30   35 20  
1220 5.5 50 3 +30 -30   35 20  
1221 5.5 50 4 +30 +30 19.5 31.5-35.1 18.3-19.4  
1222 6.0 50 1 -30 +30   35 20  
1223 6.0 50 2 -30 -30        
1224 6.0 50 3 +30 -30        
1225 6.0 50 4 +30 +30 19.5 31.5-35.1 18.3-19.4  
1226 6.5 50 1 -30 +30   35 20  
1227 6.5 50 2 -30 -30       Calibration run not properly configured @ board 8
1228 6.5 50 3 +30 -30        
1229 6.5 50 4 +30 +30        
1230 2.0 50 1 -30 +30        
1231 2.0 50 2 -30 -30        
1232 2.0 50 3 +30 -30        
1233 2.0 50 4 +30 +30        
1234 2.5 50 1 -30 +30        
1235 2.5 50 2 -30 -30        
1236 2.5 50 3 +30 -30        
1237 2.5 50 4 +30 +30        
1238 3.0 50 4 +30 +30 19.5 31.5-35.1 18.3-19.4  
1239 3.0 50 1 -30 +30        
1240 3.0 50 2 -30 -30        
1241 3.0 50 3 +30 -30       Calibration run not properly configured @ board 6, use previous calibration run
1242 5.5 50 3 +30 -30       RETAKE RUN 1220; Calibration run not properly configured @ board 11
1243 3.5 50 3 +30 -30       RETAKE RUN1202

3. X and Y scans

Run # OV (V) I@Board01 (A) N triggers (10^3) Scan over T SiPM (C) T1 Board (C) T2 SiPM (C) Comments
1300 4 9.62 85 Y-axis (X in the middle) 19.5 31.5-35.1 18.3-19.4 not very uniform distribution on y, probably because we stopped for beam cycle
1301 4 9.62 55 Y-axis (X in the middle)       without stopping for beam cycle (attempt to make it uniform)
1302 4 9.26 55 Y-axis (X=-30mm)       without stopping for beam cycle (attempt to make it uniform)
1303 4 9.26 20 Mirror-Mirror corner (X,Y)=(-70mm,+70mm)        
1304 4 9.26 55 Y-axis (X=+30mm)       ERROR (vector is empty)!!
1305 4 9.26 70 Y-axis (X=+30mm)        
1306 4 9.9 60 Y-axis (X=0mm) 17-18 31.5-35.1 18.3-19.4 RETAKE RUN 1300
1307 4 9.7 56 Y-axis (X=-30mm)       RETAKE RUN 1302
1308 4 9.3 57 X-axis (Y=0mm)   31.2-34.6 17.4-19.3  
1309 4 9.3 65 X-axis (Y=-30mm)       Trg_frq=1kHz
1310 4 9.3 62 X-axis (Y=+30mm)       Trg_frq=1kHz
4. Lead runs 1
  • LEAD placed outside in front of entrance window
  • x=0,y=0
  • collimator 3x3x3x3
  • for lower energies collimator is set to 0.7 symmetrically
Run # OV (V) I@Board01 (A) N triggers (10^3) # lead plates Trigger Freq (Hz) T SiPM (C) Beam energy (GeV) Comments
1311 4 8.96 50 1 150      
1312 4 9.0 50 2 150     empty vector, fix the logic error
1313 4 9.0 50 3 150 16.3    
1314 4 9.0 50 4 150 16.3 6  
1315 4 9.0 50 4 200 16.3 5  
1316 4 9.0 50 4 500 16.3 4  
1317 4 9.0 50 4 800 16.3 3  
1318 4 9.0 50 4 900 16.3 2  
1319 4 9.0 50 4 200 16.3 1  

5. X and Y scans after recalibration of boards

Run # OV (V) I@Board01 (A) N triggers (10^3) Scan over Collimator Energy (GeV) Trigger rate (kHz) Comments
1320 4 9.5 50 Fixed: beam in the middle     1 Tsipm=17-18, T1_board=31.0 -33.8, T2_SiPM=17.4-19.0
1321 4 9.5 50 Y-axis, X=-30mm (start Y=+85)       not all channels receive data due to beam cycle
1322 4 9.5 50 Y-axis, X=-30mm (start Y=+85)        
1323 4 9.5 50 Y-axis, X=0mm (start Y=+85)        
1324 4 9.5 50 Y-axis, X=+30mm (start Y=+85 to -70)     1.2  
1325 4 9.5 250 Y-axis, X=+30mm (start Y=+85 to -70) 10 sym 5.6 3  
1326 4 9.5 150 Y-axis, X=+30mm (start Y=+85 to -70) 5 sym 5.6 2 Enabled Gbit/s mode at switch
1327 4 9.5 150 X-axis, Y=+30mm (start X=mark to mark) 5 sym 5.6 2  
1328 4 9.5 150 X-axis, Y=0mm (start X=mark to mark) 5 sym 5.6 2  
1329 4 9.5 150 X-axis, Y=-30mm (start X=mark to mark) 5 sym 5.6 2  
1330 4 9.5 500 Fixed: (X,Y)=(0,0) 5 sym 5.6 2  
1331 4 9.5 1000 Fixed: (X,Y)=(0,0) 5 sym 5.6 2  
1332 4 9.5 1500 Fixed: (X,Y)=(+30,+30) 5 sym 5.6 2  
1333 4 9.5 1200 Fixed: (X,Y)=(+30,-30) 5 sym 5.6 2  
1334 4 9.5 1100 Fixed: (X,Y)=(-30,-30) 5 sym 5.6 2  
1335 4 9.5 1000 Fixed: (X,Y)=(-30,+30) 5 sym 5.6 2  

6. Over voltage scans: LONG runs

Run # OV (V) I@Board01 (A) N triggers(10^3) Beam position Collimator Energy (GeV) Freq Trigger (KHz) Comments
1336 4 9.5 50 (X,Y)=(0,0) 5 sym 5.6 2  
1337 4 9.5 1000 (X,Y)=(0,0) 5 sym 5.6 2  
1338 4.5 12 1000 (X,Y)=(0,0) 5 sym 5.6 2  
1339 5 14.78 1000 (X,Y)=(0,0) 5 sym 5.6 2 Calibration run not properly configured @ board 5
1340 5.5 18.84 1000 (X,Y)=(0,0) 5 sym 5.6 2  
1341 6 22.6 1000 (X,Y)=(0,0) 5 sym 5.6 2 Calibration run not properly configured @ board 2
1342 6.5 27.1 1500 (X,Y)=(0,0) 5 sym 5.8 1  
1343 2.0 4.12 1000 (X,Y)=(0,0) 5 sym 5.8 0.9  
1344 2.5 5.12 1000 (X,Y)=(0,0) 5 sym 5.8 0.9  
1345 3.0 5.12 1000 (X,Y)=(0,0) 5 sym 5.8 0.9  
1346 3.5 5.12 1000 (X,Y)=(0,0) 5 sym 5.8 0.9  
7. LEAD runs 2

Run # OV (V) I@Board01 (A) N triggers (10^3) Beam position Collimator Energy (GeV) Trigger rate (Hz) # lead plates Comments
1400 4 11 50 (X,Y)=(0,0) 5 sym 5.6 1000 0, base for lead plates installed  
1401 4 11 50 (X,Y)=(0,0) 1.5 sym 4 2000 0, base for lead plates installed  
1402 4 11 50 (X,Y)=(0,0) 1.0 sym 2 1500 0, base for lead plates installed  
1403 4 11 50 (X,Y)=(0,0) 1.4 sym 5.6 200 1 board 9, 1 pll not working
1404 4 11 50 (X,Y)=(0,0) 0.8 sym 4 500 1  
1405 4 11 50 (X,Y)=(0,0) 0.4 sym 2 300 1  
1406 4 11 50 (X,Y)=(0,0) 1.4 sym 5.6 200 2 We checked the beam spot, it was not centered, we moved it 1 cm up (check plot ADD HERE PLS); we consider it now the new center; boards 2,9,10 and 12 have plls not locking frown
1407 4 11 50 (X,Y)=(0,0)** 0.4 sym 4 200 2 From this run: new center
1408 4 11 50 (X,Y)=(0,0) 0.3 sym 2 300 2  
1409 4 10.7 50 (X,Y)=(0,0) 1.0 sym 5.6 150 3  
1410 4 11.7 50 (X,Y)=(0,0) 0.4 sym 4 180 3  
1411 4 11.7 50 (X,Y)=(0,0) 0.3 sym 2 250 3  
1412 4 11.7 50 (X,Y)=(0,0) 1.0 sym 5.6 150 4  
1413 4 10.5 50 (X,Y)=(0,0) 0.4 sym 4 200 4 Calibration run not properly configured @ boards 1,3,4,5,6,8,10
1414 4 10.9 50 (X,Y)=(0,0) 0.3 sym 2 300 4  
1415 4 10.72 50 (X,Y)=(0,0) 1.5 sym 5.6 200 5 Tsipm=18-19, T1_board=32.0-34.7, T2_SiPM=19.1-20.6
1416 4 10.5 50 (X,Y)=(0,0) 0.3;0.3;0.6;0.6 4 200 5  
1417 4 10.9 50 (X,Y)=(0,0) 0.3;0.3;0.6;0.6 2 300 5  
1418 4 10.72 50 (X,Y)=(0,0) 1.5 sym 5.6 300 6  
1419 4 10.5 50 (X,Y)=(0,0) 0.3;0.3;0.6;0.6 4 200 6  
1420 4 10.9 50 (X,Y)=(0,0) 0.3;0.3;0.6;0.6 2 300 6  
8. Emulsion runs
Pb collimator: 7mmx7mm

Rate:~1.3 Hz (1Hz electrons + 0.3 random coincidence)

Target was moved off center to reduce rate to ~1Hz

Bias voltage: 5.5 V

Run # Converter Energy(GeV) Brick Lead setup Evts@X1 Evts@X2 Evts@Y1 Evts@Y2 Comments  
1600 6, Al=1mm 6 Test run, no brick with emulsions 5mm Pb inside + 6mm Al (z=100mm) 232 221 248 255    
1601 1, Cu=5mm 6 Test run, no brick with emulsions 5mm Pb inside + 6mm Al (z=100mm) 290 284 299 309    
1602 6, Al=1mm 6 Brick #1: Pb56mm (outside)   214 203 216 219    
1603 6, Al=1mm 6 Brick #2: Pb43mm (outside)   210 202 212 213    
1604 6, Al=1mm 6 Brick #3: Pb28mm (outside)   249 249 261 261    
1605 6, Al=1mm 6 Brick #4: Pb14mm (outside)   272 261 274 275    
1606 6, Al=1mm 6 Brick #7: Pb18*0.9mm (outside)   234 233 240 236    
1607 6, Al=1mm 6 Brick #8: Pb14mm (outside) + Pb28mm (inside)   268 259 269 269    
1610 6, Al=1mm 2 Testrun with 2GeV; Target position: -16.4mm set by the ctrl room   283 282 286 296    
1611 5, Al=3mm 2? Brick #5: Pb28mm (outside) + Pb28mm (inside)   297 289 305 304    
1620 1, Cu=5mm 4 Testrun with 4GeV; Target position: -16.4mm   102 100 105 106    
1630 1, Cu=5mm 4 Testrun with 4GeV; Target position: -17.4mm   374 362 373 379    
1631 1, Cu=5mm 4 Brick #6: Pb28mm; Target position: -17.4mm   410 401 418 415    
1640 2, Cu=3mm 4 Testrun with 4GeV; Target position: -20.5mm           Rate: 50 Hz  
1641 2, Cu=3mm 4             Test sample emulsion for aging tests 1&2 6 lines (12.6 kEvts)  
1642 2, Cu=3mm 4             Test sample emulsion for aging tests 1&2 6 lines (11.6 kEvts)  
9. Tests to find the cause of non-uniformity in some STiCs

Day: 30.10.2019 [T1=20.5,T2=35.6]

Run # OV (V) Number triggers (10^3) Scan Energy(GeV) Colimmators Rate Target Comments
1700 5.5 10 x-axes 6 open 10 sym Pb=20mmx20mm 50 Hz (target -20) -20  
1701 5.5 160   6   4 Hz -26 nominal rate 4kHz (target -26 nominal) comment: just to restart
1702 5.5 160   6     -26 nominal change Board12, Stic=4 PLL Left, VNCNT from 31 to 28 and readjust pll
1703 5.5 160   6     -26 nominal change Board12, Stic=4 change ETH for ch0..9 to +2 (reduce threshold)
1704 5.5 160   6       change Board12, Stic=4 change VNCNT from 31 to 33 no amp=255 anymore confirmed!
1705 5.5 80   6       new try after pll adjustment b10,b2,b12
1706 5.5 80 ] 6       new try
Day: 31.10.2019 [T1=21.5,T2=34.6]

Run # OV (V) Number of triggers (10^3) Scan over Energy (GeV) Pb Collimators Rate Comment
1707 5.5 140 x-axes 6 20mmx20mm 3.5 sym 2 collimators open
1708 5.5 144 edge x=-80 (W) 6 20mmx20mm 3.5 sym 2 collimators open; large beam spot
1709 5.5 66 x=50 (E) 5.6 7mmx7mm 2.5 sym 1 collimators open; small beam spot
1710 5.5 1000 x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1711 5.5 240 scan y=-70 +70 x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1712 5.5 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1713 5.5 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1714 6.5 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1715 6.5 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1716 7.5 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1717 7.5 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1718 1.5 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1719 1.5 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1720 2.5 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1721 2.5 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1722 3.5 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1723 3.5 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1724 4.5 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1725 4.5 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1726 5 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1727 5 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1728 6 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1729 6 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1730 7 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1731 7 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 4 collimators open; small beam spot
1732 2 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 9 collimators open; small beam spot
1733 2 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 5 collimators open; small beam spot
1734 3 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 5 collimators open; small beam spot
1735 3 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 5 collimators open; small beam spot
1736 4 200 scan y x=50 (E) 5 7mmx7mm 2.5 sym 5 collimators open; small beam spot
1737 4 1000 y=-50 x=50 5 7mmx7mm 2.5 sym 5 collimators open; small beam spot
1738 5 11000 y=-50 x=50 5 7mmx7mm 2.5 sym 5 collimators open; small beam spot
1739 5 1000 y=-50 x=50 3 7mmx7mm 2.5 sym 15 collimators open; small beam spot
-- AnaCavalcante - 2019-10-26
Topic attachments
I Attachment History Action Size Date Who Comment
PNGpng detector_cs.png r1 manage 82.7 K 2019-10-26 - 18:56 AnaCavalcante  
PNGpng moving_table.png r1 manage 103.3 K 2019-10-26 - 18:56 AnaCavalcante  
PNGpng setup1.png r1 manage 364.8 K 2019-10-26 - 18:22 AnaCavalcante  
PNGpng setup2.png r1 manage 367.6 K 2019-10-26 - 18:22 AnaCavalcante  
PNGpng setup3.png r1 manage 383.6 K 2019-10-26 - 18:22 AnaCavalcante  
Edit | Attach | Watch | Print version | History: r12 < r11 < r10 < r9 < r8 | Backlinks | Raw View | WYSIWYG | More topic actions
Topic revision: r12 - 2020-02-07 - AnaCavalcante
 
    • Cern Search Icon Cern Search
    • TWiki Search Icon TWiki Search
    • Google Search Icon Google Search

    LHCb All webs login

This site is powered by the TWiki collaboration platform Powered by PerlCopyright & 2008-2020 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.