LHCb Detector Status during CERN Closure 19/12/2015 - 3/01/2016
Cooling
System |
Status |
If stops |
Mixed Water |
Run |
72201 (CCC/TI) |
Chilled Water |
Run |
72201 (CCC/TI) |
Compressed Air |
Run |
72201 (CCC/TI) |
HVAC UX-SX-SG |
Run |
72201 (CCC/TI) |
Detector Cooling
Detector |
Status |
If stops |
RICH |
Run |
Do not need to be restarted |
OT/SPD |
Run |
Do not need to be restarted |
IT |
Run |
Restart ASAP 72201 |
VELO |
Run |
162192/160706/165829 |
Gas
Detector |
Status |
If stops |
RICH1 |
Run (counting gas) |
Restart within 24h 162516 (Gas piquet) |
RICH2 |
Run (counting gas) |
Restart within 24h 162516 (Gas piquet) |
OT |
Run (counting gas) |
Restart ASAP 162516 (gas piquet) |
GEM |
Bkp (AR/CO2) |
Restart within 24h 162516 (Gas piquet) |
Muon |
Counting gas |
Restart within 24h 162516 (Gas piquet) |
Primary supply |
Run |
162516 (gas piquet) |
Power
Detector |
LV |
HV |
VELO |
OFF |
OFF |
RICH1 |
OFF |
OFF |
RICH2 |
OFF |
OFF |
TT |
OFF |
OFF |
IT |
OFF |
OFF |
OT |
OFF |
OFF |
M1 |
OFF |
OFF |
PS/SPD |
OFF |
OFF |
ECAL |
OFF |
OFF |
HCAL |
OFF |
OFF |
M2-M5 |
OFF |
OFF |
HRC |
OFF |
OFF |
Racks - All OFF except
Or
Online - Web Services
Safety System
System |
Status |
CSAM |
All Running |
DSS |
Running, some alarms disabled (**) |
(**)List of DSS alarms disabled or with disabled actions:
Contacts
- DSS - Infrastructure - RP 168000 back-up: 162029 (ET) 162989 (LR) 163052 (RL) 162112 (GC) 169056 (HS) 163051 (MK)
- VELO Piquet 165829
- ST Piquet 160425
- OT Piquet 160956 168680
- RICH Piquet 161848
- Calo Piquet 161822
- Muon Piquet 161911
- Any other problem : 72201 (CCC/TI)
Access
Special measures YETS 2015/16 : Access strictly limited to EMERGENCIES
- Access request https://edh.cern.ch/Document/General/ACRQ
(needed also for surface building and site)
- In addition usual access conditions apply (impacts, trainings, etc)
- Access control system status: CLOSED. In case of urgent access: contact 168000.