Table of contents:
Data used in the analysis
168318 168341 168362 168461 168826 169045
168322 168356 168458 168514 169035 169091
168325 168361 168460 168777 169040 169099
# of events in the analysis
- EMCal trigger (all the centrality) ; 250,000
- Central trigger ; 2,000,000
Energy distribution
Energy distribution in EMCal trigger
- (action) Check exotic cluster
Comparison Max tower Energy and All cluster in EMCal trigger
- Maximum tower energy distribution is identical with cluster energy distribution without any trigger cluster selection above the threshold.
- In most central, these distributions are different above the threshold
Comparison between EMCal trigger (Central) and Central trigegr
- Cluster energy distribution with the EMCal trigger in the most central (0-10%) is well match with the distribution with the central trigger after arbitrary scale above the threshold.
- (action) compare with narrow centrality
E/p
Central trigger
- Large hadron contamination at low pT due to dE/dx selection. Need to check.
- (action) show the fitting
- (action) first fit the narrow gauss to find peak and width
E/p peak position & resolution
- peak position ; ~ 7 % higher than unit
Raw Electron yields
Central trigger (uncorrected background)
- Uncorrected background hadron correction
- (action) subtracting background
- (action) compare with cluster energy distribution
Next to do
- shower shape
- track matching
- Occupancy
- phi and eta dependence of PID (E/p, dE/dx)
- Increase statistics to see electrons in EMCal trigger
--
ShingoSakai - 22-Feb-2012