ES-EE slopes obtained from SimHits
Fitting by other method:
cut the histrogram per 20 MIP and use gaussian fit.
Fitting range is from (the location of peak value -1) to 1.5 RMS
then fit the value of each bin's mean value by straight line fit to get slope.
for example:
one bin fitting:
Then we get slope by getting each bin's mean valuse:
Results:
- Slope of Different Eta and Pt
- Offset of Different Eta and Pt
Pt=100 Eta=1.7 (slope = p1)
Fitting Range: 0~2400 & Entries of each bin
Fitting Range 0~2100 Fitting Range 0~1800
Fitting Range 0~1500 Fitting Range 0~1200
Pt=100 Eta=2.0
Fitting Range: 0~2520 & Entries of each bin
Fitting Range 0~2200 Fitting Range 0~1900
Fitting Range 0~1600 Fitting Range 0~1300
Pt=100 Eta=2.3
Fitting Range: 0~2680 & Entries of each bin
Fitting Range 0~2400 Fitting Range 0~2100
Fitting Range 0~1800 Fitting Range 0~1500
Conclustion: Effect of fitting range on slope is fine.
- Energy Resolution of Different Operation Modes
Only use 2nd ES plane to recover the energy
- Energy resolution of only 2nd plane (only add 2nd plane's energy back)
- Energy resolution of RecHits by Clustering
- Reconstructed energy spectrum using clustering
Pt = 10, Eta = 1.7

--
ChiaMingKuo - 2009-09-14