Procedure to execute the power cycle on Ladder -609

This procedure should be done every ~ 20 days, after informing the collaboration during the 5 o'clock meeting.

1. Go to the directory
cd /pocchome/tracker/TrackerExpert/JMDCCommander/


2. Check that command_path.conf contains the correct configuration to send commands, it should be
eas:hosc feplr or eas:hosc pcposp0

3. Launch the program that execute the power cycle on the front end of ladder TkID-609 (HwID 605)
./recycle_hw605_tk609M.txt


4. Update the List of power cycles executed on ladder -609 in
https://twiki.cern.ch/twiki/bin/view/Main/Ladder-609PowerCycles


5. Write on the TEE Elog, that you have done the power cycle on ladder -609
example: 14:55 Tracker: Cycled power on FE Y-side of ladder TDR-6-05 (MG e MD)




-- MauraGraziani - 03 Dec 2013