TWiki> Main Web>AmsTracker>PowerOnOffCrate (revision 1)EditAttachPDF

Procedures to turning ON/OFF of a specific part of the tracker

The procedure outlined below might come in handy in case of some tracker crate was switched off. That might happen due to some power failure on the ISS. In the following I will use the situation where the crates 2 and 6 needs to be restarted.

In order to turn ON/OFF a specific crate:

  1. Go in the directory SwitchHybridsWholeTracker
    cd /pocchome/tracker/TrackerExpert/JMDCCommander/power_step_scripts/
  2. Make sure that two JINFs are ON. Ask
  3. Execute (this sends commands):
    =my-tttt JINF_2.com=
    my-tttt JINF_6.com
  4. Check taht the JINFs are off now
  5. Use GlowGUI to check that everything is powered up properly.

Having two JINF turned on
Basically, you should ask LEAD Expert (M.Capell or X.Cai) for that.

You can check that the appropriate JINFS are on JINF eas:hosc feplr

-- KostyaKanishchev - 2015-09-16

Edit | Attach | Watch | Print version | History: r2 < r1 | Backlinks | Raw View | Raw edit | More topic actions...
Topic revision: r1 - 2015-09-16 - KostyaKanishchev
 
    • Cern Search Icon Cern Search
    • TWiki Search Icon TWiki Search
    • Google Search Icon Google Search

    Main All webs login

This site is powered by the TWiki collaboration platform Powered by PerlCopyright & 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback