A) I cannot see anything in the AMI interface
Have you selected the right power side (TTCE-A or TTCE-B)?
Check the status of the scanning daemons following the procedure
here.
Tracker Troubleshooting
Symptom | Possible Cause | Action to be taken |
Unusual pedestal and noise distribution, in particular with peack at low value, due to a single hybrid. |
Hybrid analog power malfunctioning |
Verify the LR status in AMI. Try to set the LR on. |
Unusual pedestal and noise distribution, due to several ladders. |
Absence of Vbias | Verify the appropriate Vbias value in AMI. If Vbias is off, select the other (cold) DC/DC converter |
Unusual pedestal and noise distribution, due to several ladders. |
Absence of analog power (+/- 2.5 Volts) on several ladders. |
nothing to do |
No comunication with half of the TDRs of a crate. |
Absence of ditial power (+3.3 V) |
Select the other DC/DC converter (hot). If the problem is solved, ask the DAQ expert to remove the hot/cold transition in the relevant power step.
|
|
|
|
|
|
|
|
|
|