TWiki
>
SPL Web
>
Linac4Web
>
HighPowerUpgrade
(revision 1) (raw view)
Edit
Attach
PDF
---+ Upgrade to high duty cycle This page contains a list of items that need to be changed/modified, when Linac4 is upgraded to high duty cycle to act as a front-end for the high-power SPL. It doesn't claim to be complete but hopefully it will grow with time. %EDITTABLE{header="| *Equipment* | *Change* | *Comment* | *Date of note* |" format="| text, 30 | text, 40 | text, 30 | date,10 |" changerows="on" }% |*Equipment*|*Change*|*Comment*|*Date of note*| | klystron modulators | upgrade to 50 Hz | complete replacement | 3 September 2008 | | cooling water in RF structures | needs to be changed to demineralised water | otherwise the high flow speed of town water in the cooling channels will erode the channels and yield leaks | 3 September 2008 | -- Main.FrankGerigk - 03 Sep 2008