All in complete simulation except one point for the W to study the linearity.
nb |
Requester |
Event Type |
#evts |
Software + Lumi |
PU 20/BX |
PU 60/BX |
PU 100/BX |
PU 140/BX |
Other? |
1 |
ECAL |
Z->ee (eta_e1 eta_e2 in -1.5 to 1.5) |
30000x4agingx3PU |
0-300-1000-3000 fb-1 |
yes |
yes |
no |
yes |
complete (py special + Inter-Calib special) |
2 |
ECAL |
Z->ee (eta_e1 eta_e2 in 1.45 to 4 ) |
30000x4agingx3PU |
0-300-1000-3000 fb-1 |
yes |
yes |
no |
yes |
complete (py special + Inter-Calib special) |
3 |
ECAL |
Z->ee (eta_e1 eta_e2 in 1.45 to 4 ) |
30000x2agingx3PU without ES |
0-3000 fb-1 |
yes |
yes |
no |
yes |
ECAL private production |
4 |
ECAL |
W->enu (eta_e in 1.45 to 4) |
30000x4agingx3PU |
0-300-1000-3000 fb-1 |
yes |
yes |
no |
yes |
complete (py special + Inter-Calib special) |
5 |
ECAL |
W->enu (eta_e in 1.45 to 4) effective simulation |
30000x4agingx1PU |
0-300-1000-3000 fb-1 |
yes |
no |
no |
no |
effective |
6 |
ECAL |
H->gg |
20000x4agingx3PU |
0-300-1000-3000 fb-1 |
yes |
yes |
no |
yes |
effective |
7 |
ECAL |
H->gg VBF |
10000x4agingx3PU |
0-300-1000-3000 fb-1 |
yes |
yes |
no |
yes |
effective |
8 |
ECAL |
H->ZZ->4e |
10000x4agingx3PU |
0-300-1000-3000 fb-1 |
yes |
yes |
no |
yes |
effective |
9 |
ECAL |
HH->4e gg |
10000x2agingx2PU |
0-3000 fb-1 |
yes |
no |
no |
yes |
effective |
10 |
ECAL |
HH->gg gg |
10000x2agingx2PU |
0-3000 fb-1 |
yes |
no |
no |
yes |
effective |
11 |
ECAL |
HZ->gg bb |
10000x2agingx2PU |
0-3000 fb-1 |
yes |
no |
no |
yes |
effective |
12 |
ECAL |
HH->gg bb |
10000x2agingx2PU |
0-3000 fb-1 |
yes |
no |
no |
yes |
effective |
13 |
ECAL |
M. Graph 2 photons |
100000x2agingx2PU |
0-3000 fb-1 |
yes |
no |
no |
yes |
effective |
14 |
ECAL |
M. Graph Gamma+jet |
100000x2agingx2PU |
0-3000 fb-1 |
yes |
no |
no |
yes |
effective |
Lumi scenarios with PU |
Scenario Number |
Geometry |
Average Pileup |
Luminosity |
Pixel aged |
Strips aged |
EB aged |
EE aged |
HB aged |
HE aged |
HF aged |
Comments |
0 |
Phase 1 |
70 |
300 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
CMS aged detectors by LS3 (nominal - 70 PU) |
1 |
Phase 1 |
70 |
500 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
CMS aged detectors if LS3 delayed - 70 PU |
2 |
Phase 1 |
70 |
1000 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
CMS aged detectors if LS3 canceled - 70 PU |
|
|
|
|
|
|
|
|
|
|
|
|
3 |
Phase 1 |
140 |
1000 |
No |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
PostLS3 strips/Pixel changed but phase1 geom for tracking |
|
|
|
|
|
|
|
|
|
|
|
|
4 |
Phase 1 |
140 |
1000 |
No |
No |
Yes |
No |
Yes |
No |
Yes |
PostLS3 Jeff's mixed scenario #1 |
5 |
Phase 1 |
140 |
1000 |
No |
No |
Yes |
No |
Yes |
No |
No |
PostLS3 Jeff's mixed scenario #2 |
|
|
|
|
|
|
|
|
|
|
|
|
6 |
Phase 2 x 3 geom |
140 |
1000 |
No |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
PostLS3 strips/Pixel changed but phase2 geom no tracking |
7 |
Phase 1 |
140 |
3000 |
No |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
Post- PostLS3 strips/Pixel 'new' but phase1 geom for tracking |
SAME AS ABOVE WITHOUT PU (pure detector performance - no reco effect) |
Scenario Number |
Geometry |
Average Pileup |
Luminosity |
Pixel aged |
Strips aged |
EB aged |
EE aged |
HB aged |
HE aged |
HF aged |
Comments |
8 |
Phase 1 |
0 |
300 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
CMS aged detectors by LS3 (No PU) |
9 |
Phase 1 |
0 |
500 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
CMS aged detectors if LS3 delayed - (No PU) |
10 |
Phase 1 |
0 |
1000 |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
CMS aged detectors if LS3 canceled - (No PU) |
|
|
|
|
|
|
|
|
|
|
|
|
11 |
Phase 1 |
0 |
1000 |
No |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
PostLS3 strips/Pixel changed but phase1 geom for tracking (No PU) |
|
|
|
|
|
|
|
|
|
|
|
|
12 |
Phase 1 |
0 |
1000 |
No |
No |
Yes |
No |
Yes |
No |
Yes |
PostLS3 Jeff's mixed scenario #1(No PU) |
13 |
Phase 1 |
0 |
1000 |
No |
No |
Yes |
No |
Yes |
No |
No |
PostLS3 Jeff's mixed scenario #2(No PU) |
|
|
|
|
|
|
|
|
|
|
|
|
14 |
Phase 2 x 3 geom |
0 |
1000 |
No |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
PostLS3 strips/Pixel changed but phase2 geom no tracking (No PU) |
15 |
Phase 1 |
0 |
3000 |
No |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
Post- PostLS3 strips/Pixel 'new' but phase1 geom for tracking(No PU) |
PERFECT CMS detector - No aging - No PU |
Scenario Number |
Geometry |
Average Pileup |
Luminosity |
Pixel aged |
Strips aged |
EB aged |
EE aged |
HB aged |
HE aged |
HF aged |
Comments |
16 |
Phase 1 |
0 |
- |
No |
No |
No |
No |
No |
No |
No |
IDEAL CASE |
17 |
Phase 2 x 3 geom |
0 |
- |
No |
No |
No |
No |
No |
No |
No |
IDEAL CASE |
Second table for upgrade production
Topic revision: r20 - 2013-04-25
- unknown