FRU - field replaceable unit
IPMI - intelligent platform management interface
IPMB - intelligent platform management bus
Command | Parameters | Description |
---|---|---|
getenv | Gets value of environment variable | |
ifconfig | Prints the configuration | |
setenv rc_ifconfig y | Allows the /etc/rc script to set up the IP address instead of shelfman (this is how we allowed the IP address to be assigned to eth0) | |
clia setlanconfig | channel parameter name or number additional parameters |
Sets the value of the LAN configuration parameter for the specified channel |
clia setlanconfig 1 dft_gw_ip | ip address | Sets default gateway IP of SM eth0 |
clia setlanconfig 1 ip | ip address | Sets IP address of SM eth0 |
Command | Parameters | Description |
---|---|---|
clia board | Get standard information about all boards in the shelf | |
clia board -v | physical slot address | Get verbose information about a board in physical slot |
clia activate board | physical slot number | Activates specified board |
clia deactivate board | physical slot number | Deactivates specified board |
Command | Parameters | Description |
---|---|---|
clia setfanpolicy | fan tray address fan tray fru_id ENABLE/DISABLE |
Enables/Disables SM control over fan trays for colling management purposes |
clia getfanpolicy | fan tray address fan tray fru_id |
Retrieves information about fan tray(s) control mode and/or FRUs coverage by the specified fan tray(s) |
clia setfanlevel | Sets a new level for the fan controlled by the FRU specified in the command parameters |
Command | Parameters | Description |
---|---|---|
clia getthreshold | Shows current threshold values for the supported thresholds of the specified sensor(s) | |
clia setthreshold | IPMB address sensor name threshold type -r value |
Changes current threshold value. Threshold type: upper_non_recoverable, upper_critical, upper_non_crittical, lower_non_recoverable, lower_critical, lower_non_critical. Option -r means that a raw value is used, usually a byte-size quantity, converted according to sensor-specific rules |
Command | Parameters | Description |
---|---|---|
clia sensordata | Shows value of threshold-based sensor and asserted states for discrete sensor | |
clia showunhealthy | Shows list of FRUs that appears to have a problem | |
clia shelf | -v cooling_state | Verbose current cooling state of shelf: normal, minor alert, major alert, critical alert |
Command | Parameters | Description |
---|---|---|
clia alarm | clear info minor major critical |
If enter without parameters, returns status. Minor/Major/Critical allows user to set corresponding alarm output, actions are cumulative |