ATLAS HGTD TestBeam Sensor Information

Introduction

This twiki contains the information about the sensors tested in the Test Beams .

Mailing list and password

The mailing list for HGTD Test Beam Sensor studies is: atlas-larg-upgrade-hgtiming-sensors@cernNOSPAMPLEASE.ch

Link to HGTD sensor CERNBox : HGTD Sensor CERNBox
The password to access the HGTD Sensor CERNBox : HGTDsensors

How To Perform C-V Test: Procedure_for_C-V_testing.pdf

Sensor Information

Vendor Run Number Senosr Fluence Sensor Breaking Information Comments IV Curve CV Curve
Voltage Current Temp/Humidity Annealed
CNM 10924 W6-S1034             1,2,3,4  
CNM 10924 W6-S1083             1,2,3  
CNM 10478 W5-S1011             link  
CNM 10924 W6-S1004             link  
CNM 10924 W6-S1035             link  
CNM 10924 W6-S1042             link  
CNM 10924 W6-S1080             link  
FBK   W2_4R_04             link link
FBK   W3_4R_19             link link
FBK   W4_4R_32             link link
FBK   FBK W8 1.6E15 ~800V       Burn mark between the GR and the active area    
HPK   80C 6E15 850V slightly over 1uA -20C        
HPK   Type B 3E15 500-520V shot up instantly          
HPK   Type H 1.6E15 320V around 1uA -20C/~30% Yes No evident burn marks    
HPK   Type G 1.6E15 500V 1.6 uA -27C/~40% Yes Burn mark on the metal ring outside the detector    
HPK   HPK3 Type F 1.6E15 565V 2.3uA at 570V, 1.7uA at 565V -27C/~52% Yes      
HPK   HPK3 Type G 6.4E15 490-495V >2.5uA at 490V -20C/~46% Yes No evident burn marks    
HPK   HPK3 sample G #6 1.6E15 490V     Yes      

ID Vendor RunNumber Sensor Fluence Sensor Breaking Information Comments IVCurve CVCurve Data
BreakDownVoltage CurrentAtBreakdown TemperatureAtBreakdown HumidityAtBreakdown Annealed
1 CNM 10924 W6-S1034 Link
2 CNM 10924 W6-S1083 Link
3 CNM 10478 W5-S1011 Link
4 CNM 10924 W6-S1004 Link
5 CNM 10924 W6-S1035 Link
6 CNM 10924 W6-S1042 Link
7 CNM 10924 W6-S1080 Link
8 FBK W2-4R-04 Link Link
9 FBK W3-4R-19 Link Link
10 FBK W4-4R-32 Link Link
11 FBK FBK W8 1.6E+015 ~800V Burn mark between the GR and active area
12 HPK 80C 6E+015 850V slightly over 1uA -20C
13 HPK Type B 3E+015 500-520V shot up instantly
14 HPK Type H 1.6E+015 320V around 1uA -20C ~30% Yes No evident burn marks
15 HPK Type G 1.6E+015 500V 1.6uA -27C ~40% Yes Burn marks on metal ring outside the detector
16 HPK HPK3 Type F 1.6E+015 565V "2.3uA at 570V 1.7uA at 565V" -27C ~52% Yes
17 HPK HPK3 Type G 6.4E+015 490-495V >2.5uA at 490V -20C ~46% Yes No evident burn marks
18 HPK HPK3 Sample G#6 1.6E+015 490V Yes

-- AnindyaGhosh - 2018-08-07

Topic attachments
I Attachment History Action Size Date Who Comment
PDFpdf Procedure_for_C-V_testing.pdf r1 manage 397.7 K 2018-08-07 - 15:16 AnindyaGhosh C-V Testing Procedure
Edit | Attach | Watch | Print version | History: r12 < r11 < r10 < r9 < r8 | Backlinks | Raw View | WYSIWYG | More topic actions
Topic revision: r12 - 2018-09-19 - AnindyaGhosh
 
    • Cern Search Icon Cern Search
    • TWiki Search Icon TWiki Search
    • Google Search Icon Google Search

    Sandbox All webs login

This site is powered by the TWiki collaboration platform Powered by PerlCopyright &© 2008-2023 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
or Ideas, requests, problems regarding TWiki? use Discourse or Send feedback