Muon Spectrometer Data Quality White Board

Muon ATLAS Control Room 71363 & 71365
Muon Satellite Control Room 70948
Muon Run Coordinators: Stephanie Zimmermann (163050) and Enrico Pasqualucci (162197)
Muon White Board: https://twiki.cern.ch/twiki/bin/view/Sandbox/MuonWhiteBoard

DQ Responsibilities

SubDetector System People Involved
MDT Online Monitoring TDAQ Software Enrico Pasqualucci, Roberto Ferrari, Serguei Kolos
MDT Online Monitoring DQMF and OHP William Johnson, Joe Rotheberg, Siyuan Sun
MDT Online Monitoring Gnam Daniela Salvatore, Gabriella Gaudio
MDT Offline Monitoring Heather Russel, Rachael Rosten, Tony Tong, Yanlin Liu
CSC Online Monitoring Michael Schernau
CSC Offline Monitoring Ken Johns, Jason Veatch
RPC Online Monitoring Alessia Bruni
TGC Online Monitoring Daniel Lellouch

Known DQ Issues

SubDetector Chambers Affected Error Message Cause and Plan of Action Author
MDT All MDT Chambers Chamber Error Histogram Tagged Red in DQMF Chamber error histogram not calibrated correctly. Ignore all red chamber error plots S. Sun
MDT All MDT Chambers ADC histogram algorithm disabled ADC (pulse height) distribution is not useful for cosmic muon runs, ADC algorithm now always returns green in order to avoid unnecessary red flags S. Sun
CSC All CSC Chambers CSC DQMF is not ready CSC DQMF needs tuning on both algorithm and organization of histograms. The plan is to upload the timing, charge, occupancy, and error plots for every chamber to be uploaded to CSC DQMF and remove them from OHP S. Sun
CSC All CSC Chambers CSC monitoring data stream to be tested CSC's new data stream "monitoring stream" needs to be tested in M8 S. Sun
RPC All RPC Chambers RPC DQMF is not ready RPC DQMF needs tuning on both algorithm and organization of histograms. The plan is have two trees one organized by detector geometry (sectors/towers) and one organized by electronic readout (RODS). Timing and occupancy plots will be made for each tower. Alignment of the readout clocks and error histograms will be displayed for each ROD. Respective plots will then be removed from OHP S. Sun
TGC All TGC Chambers TGC does not have pentane gas TGC does not have the needed gas and is not currently included in the combined run S. Sun
Edit | Attach | Watch | Print version | History: r1 | Backlinks | Raw View | WYSIWYG | More topic actions
Topic revision: r1 - 2015-02-08 - SiyuanSun
 
    • Cern Search Icon Cern Search
    • TWiki Search Icon TWiki Search
    • Google Search Icon Google Search

    Sandbox All webs login

This site is powered by the TWiki collaboration platform Powered by PerlCopyright &© 2008-2023 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
or Ideas, requests, problems regarding TWiki? use Discourse or Send feedback