Prescales for 7e31
Scenarios:
- 2e32
- 60 x 60, 7e31
- intermediate: 3e31
- 8 x 8, 1e31
- 1 x 1, 1e30
L1 prescales
All seeds unprescaled but:
L1 seed |
2e32 |
7e31 |
3e31 |
1e31 |
1e30 |
L1_SingleEG5 |
p=30 |
p=10 |
p=5 |
p=1 |
p=1 |
L1_SingleJet16 |
p=1500 |
p=500 |
p=250 |
p=80 |
p=10 |
L1_DoubleEG3 |
p=30 |
p=10 |
p=5 |
p=1 |
p=1 |
L1_SingleMuOpen |
p=30 |
p=10 |
p=5 |
p=1 |
p=1 |
Seeds prescaled only at 2e32: |
L1_SingleJet36 |
p=10 |
p=1 |
p=1 |
p=1 |
p=1 |
L1_DoubleEG5 |
p=3 |
p=1 |
p=1 |
p=1 |
p=1 |
L1_SingleMu3 |
p=5 |
p=1 |
p=1 |
p=1 |
p=1 |
HLT prescales
For the 2E32 column, the unprescaled 7E31 physics triggers I see that seem like candidates for prescaling are (as far as rates only):
HLT_HT260 ~32Hz unprescaled
HLT_Mu12 ~47Hz
HLT_Jet190 ~16Hz
HLT_DoubleMu3_Quarkonium_v1 ~15Hz
HLT_Mu15 (~19 Hz) and HLT_HT300 (~17 Hz) would also be high, though prescaling those too would mean jumping 2 thresholds.
Prescale also HLT_DiJet70_PT70_v1 ?
Sorry, I just realized there are two more muon monitoring triggers that I missed the prescales for. To get the ~1Hz allocated at 7E31, I think it would be:
HLT_Mu5_L2Mu2 p=10
HLT_Mu5_L2Mu2_Jpsi p=2
When one single number is given, this is the HLT prescale.
When two numbers are given, these are : p(L1) x P(HLT).
- Jet :
- HLT_Jet30 (on L1_SingleJet16) : 500 x 50
- HLT_Jet60 : 1000
- HLT_Jet80 : 200
- HLT_Jet110 : 60
- HLT_Jet150 : 20
- HLT_DiJetAve15U (on L1_SingleJet16) : 500 x 50
- HLT_DiJetAve30U : 1000
- HLT_DiJetAve50U : 200
- HLT_DiJetAve70U : 30
- HLT_DiJetAve100U : 20
- HLT_DiJetAve140U : 5
- HT :
- HLT_HT150 : 100
- HLT_HT200 : 30
- HLT_MR100 : 60
- MultiJet :
- HLT_QuadJet40 : 10
- HLT_ExclDiJet60_HFOR : 100
- MET :
- HLT_DiJet60_MET45 : 5
- HLT_MET100 : 10
- HLT_MET120 : 5
- Muons:
- HLT_Mu3 : 10 x 100
- HLT_Mu5 : 500
- HLT_Mu8 : 100
- HLT_DoubleMu3 : 5
- HLT_Mu3_Track3_Jpsi : 2
- L1 and L2 pass-throughs:
- HLT_L1SingleMuOpen : 10 x 100 (should give 10 Hz, in Comm. PD)
- HLT_L1SingleMuOpen_DT : 10 x 10 (should give 10 Hz, in Comm. PD)
- HLT_L1SingleMu10 : 300
- HLT_L1SingleMu20 : 100
- HLT_L2Mu10 : 100
- HLT_L2Mu20 : 25
- BJet
- HLT_BTagMu_DiJet20_Mu5 : 50
- Electrons:
- HLT_Ele8_v1 : 10 x 100
- HLT_Ele8_CaloIdL_CaloIsoVL_v1 : 10 x 50
- HLT_Ele8_CaloIdL_TrkIdVL_v1 : 10 x 30
- HLT_Ele8_CaloIdL_CaloIsoVL_Jet40_v1 : 10 x 8
- HLT_Ele15_CaloIdVT_CaloIsoT_TrkIdT_TrkIsoT_v1 : 10
- HLT_Ele15_CaloIdVT_TrkIdT_LooseIsoPFTau15_v1 : 3
- HLT_Ele17_CaloIdL_CaloIsoVL_v1 : 50
- HLT_Ele25_CaloIdVT_TrkIdT_CentralJet30_v1 : 10
- HLT_Ele25_CaloIdVT_TrkIdT_CentralDiJet30_v1 : 3
- Photons :
- HLT_Photon30_CaloIdVL_v1 : 50
- HLT_Photon30_CaloIdVL_IsoL_v1 : 30
- HLT_Photon26_Photon18_v1 : 10
- HLT_Photon75_CaloIdVL_v1 : 2
- x-channels:
- Commissioning and MB : see Steph